Vladimir N. Epov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Vladimir N. Epov has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- David Amouroux
Universite de Pau et des Pays de l'Adour, E2S UPPA, CNRS, IPREM, Institut des Sciences Analytiques et de Physico-chimie pour l'Environnement et les matériaux, Pau, 64000, France
4 shared publications - Christophe Pécheyran
Institut des Sciences Analytiques et de Physico‐chimie pour l'environnement et les Matériaux IPREM UMR 5254 ‐ UPPA/CNRS Pau France
3 shared publications Olivier F. X. Donard
LCABIE – Laboratoire de Chimie, Analytique Bio-inorganique et Environnement, IPREM, CNRS-UPPA-UMR-5254, Hélioparc, 2 Avenue du Président, Pierre Angot, 64053 Pau, France
3 shared publicationsOlivier F.X. Donard
Laboratoire de Chimie Analytique Bio-Inorganique et Environnement (LCABIE), Institut Pluridisciplinaire de Recherche sur l'Environnement et les Matériaux (IPREM), Université de Pau et des Pays de l'Adour UMR CNRS-5254, 2 Avenue du President Angot, Pau 64053, France
2 shared publications- Pablo Rodríguez-González
Department of Physical and Analytical Chemistry, University of Oviedo, Oviedo, Spain
2 shared publications - Sylvain Bérail
IPREM, Centre National de la Recherche Scientifique, Pau, France
2 shared publications
Latest Publications
- 21 May 2012
- Published by Wiley
- p. 495-517
Isotopic Analysis via Multi‐Collector Inductively Coupled Plasma Mass Spectrometry in Elemental Speciation
- 21 May 2012
- Published by Wiley
- p. 495-517
Isotopic Analysis via Multi‐Collector Inductively Coupled Plasma Mass Spectrometry in Elemental Speciation
- 7 December 2011
- Published by Wiley in Mass Spectrometry Reviews
- Vol. 31 (4) , 504-521
Species‐specific stable isotope analysis by the hyphenation of chromatographic techniques with MC‐ICPMS
This work reviews the basis and all the existing publications on the hyphenation of chromatography‐based techniques to MC‐ICPMS for isotopic studies that were published until the end of 2010. A brief historical retrospective of the measurement of isotope ratios from transient signals by ICPMS with different sample introduction techniques is also included. The most important experimental parameters and data reduction strategies affecting the accurate and precise measurement of compound‐specific isotope ratios by either HPLC or GC coupled to MC‐ICPMS are discussed. All the applications are reported and critically reviewed in terms of analytical characteristics, performances, optimization, advantages and disadvantages and future applicability to the environmental, geochemical, or bioinorganic studies. © 2011 Wiley Periodicals, Inc. Mass Spec Rev 31:504–521, 2012
- 7 December 2011
- Published by Wiley in Mass Spectrometry Reviews
- Vol. 31 (4) , 504-521
Species‐specific stable isotope analysis by the hyphenation of chromatographic techniques with MC‐ICPMS
This work reviews the basis and all the existing publications on the hyphenation of chromatography‐based techniques to MC‐ICPMS for isotopic studies that were published until the end of 2010. A brief historical retrospective of the measurement of isotope ratios from transient signals by ICPMS with different sample introduction techniques is also included. The most important experimental parameters and data reduction strategies affecting the accurate and precise measurement of compound‐specific isotope ratios by either HPLC or GC coupled to MC‐ICPMS are discussed. All the applications are reported and critically reviewed in terms of analytical characteristics, performances, optimization, advantages and disadvantages and future applicability to the environmental, geochemical, or bioinorganic studies. © 2011 Wiley Periodicals, Inc. Mass Spec Rev 31:504–521, 2012
- 23 February 2011
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 26 (6) , 1142-1156
Modern mass spectrometry for studying mass-independent fractionation of heavy stable isotopes in environmental and biological sciences
This is the first review to focus specifically on the application of modern mass spectrometry techniques for studying mass-independent or anomalous isotope fractionation for ‘heavy’ elements. This review covers a period of ten years, starting from 2000. In the first part of the manuscript, we address theoretical aspects of mass-independent isotope fractionation, such as nuclear volume and nuclear spin effects. Secondly, most published articles on this topic to date are reviewed. Mass-independent isotope fractionation was determined by ICP-MS, MC-ICP-MS or TIMS for nineteen elements so far: Hg, Sn, Cd, Zn, Te, Sr, Pb, Cr, U, Ti, Ni, Mo, Ru, Ba, Nd, Sm, Gd, Yb and Hf, as reported in about fifty publications. In addition, mass-independent fractionation was observed for some other elements, silicon, germanium and sulfur, by other techniques.
- 23 February 2011
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 26 (6) , 1142-1156
Modern mass spectrometry for studying mass-independent fractionation of heavy stable isotopes in environmental and biological sciences
This is the first review to focus specifically on the application of modern mass spectrometry techniques for studying mass-independent or anomalous isotope fractionation for ‘heavy’ elements. This review covers a period of ten years, starting from 2000. In the first part of the manuscript, we address theoretical aspects of mass-independent isotope fractionation, such as nuclear volume and nuclear spin effects. Secondly, most published articles on this topic to date are reviewed. Mass-independent isotope fractionation was determined by ICP-MS, MC-ICP-MS or TIMS for nineteen elements so far: Hg, Sn, Cd, Zn, Te, Sr, Pb, Cr, U, Ti, Ni, Mo, Ru, Ba, Nd, Sm, Gd, Yb and Hf, as reported in about fifty publications. In addition, mass-independent fractionation was observed for some other elements, silicon, germanium and sulfur, by other techniques.
- 1 January 2011
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 13 (29) , 13222-13231
Magnetic isotope effect and theory of atomic orbital hybridization to predict a mechanism of chemical exchange reactions
A novel approach is suggested to investigate the mechanisms of chemical complexation reactions based on the results of Fujii with co-workers; they have experimentally observed that several metals and metalloids demonstrate mass-independent isotope fractionation during the reactions with the DC18C6 crown ether using solvent-solvent extraction. In this manuscript, the isotope fractionation caused by the magnetic isotope effect is used to understand the mechanisms of chemical exchange reactions. Due to the rule that reactions are allowed for certain electron spin states, and forbidden for others, magnetic isotopes show chemical anomalies during these reactions. Mass-independent fractionation is suggested to take place due to the hyperfine interaction of the nuclear spin with the electron spin of the intermediate product. Moreover, the sign of the mass-independent fractionation is found to be dependent on the element and its species, which is also explained by the magnetic isotope effect. For example, highly negative mass-independent isotope fractionation of magnetic isotopes was observed for reactions of DC18C6 with SnCl2 species and with several Ru(III) chloro-species, and highly positive for reactions of this ether with TeCl6 2 −, and with several Cd(II) and Pd(II) species. The atomic radius of an element is also a critical parameter for the reaction with crown ether, particularly the element ions with [Kr]4dn5sm electron shell fits the best with the DC18C6 crown ring. It is demonstrated that the magnetic isotope effect in combination with the theory of orbital hybridization can help to understand the mechanism of complexation reactions. The suggested approach is also applied to explain previously published mass-independent fractionation of Hg isotopes in other types of chemical exchange reactions.
- 1 January 2011
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 13 (29) , 13222-13231
Magnetic isotope effect and theory of atomic orbital hybridization to predict a mechanism of chemical exchange reactions
A novel approach is suggested to investigate the mechanisms of chemical complexation reactions based on the results of Fujii with co-workers; they have experimentally observed that several metals and metalloids demonstrate mass-independent isotope fractionation during the reactions with the DC18C6 crown ether using solvent-solvent extraction. In this manuscript, the isotope fractionation caused by the magnetic isotope effect is used to understand the mechanisms of chemical exchange reactions. Due to the rule that reactions are allowed for certain electron spin states, and forbidden for others, magnetic isotopes show chemical anomalies during these reactions. Mass-independent fractionation is suggested to take place due to the hyperfine interaction of the nuclear spin with the electron spin of the intermediate product. Moreover, the sign of the mass-independent fractionation is found to be dependent on the element and its species, which is also explained by the magnetic isotope effect. For example, highly negative mass-independent isotope fractionation of magnetic isotopes was observed for reactions of DC18C6 with SnCl2 species and with several Ru(III) chloro-species, and highly positive for reactions of this ether with TeCl6 2 −, and with several Cd(II) and Pd(II) species. The atomic radius of an element is also a critical parameter for the reaction with crown ether, particularly the element ions with [Kr]4dn5sm electron shell fits the best with the DC18C6 crown ring. It is demonstrated that the magnetic isotope effect in combination with the theory of orbital hybridization can help to understand the mechanism of complexation reactions. The suggested approach is also applied to explain previously published mass-independent fractionation of Hg isotopes in other types of chemical exchange reactions.
- 14 June 2010
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 82 (13) , 5652-5662
Approach to Measure Isotopic Ratios in Species Using Multicollector-ICPMS Coupled with Chromatography
A new approach was demonstrated for the isotope ratio measurement in different elemental species of Hg using transient signal obtained by chromatography coupled with multicollector-inductively coupled plasma mass spectrometry (MC-ICPMS). The method based on the slope of linear regression by transient intensities of different isotopes shows improved accuracy and reproducibility (0.2−0.5‰ as 2 standard deviation (SD)). Internal precision (RSD) of the method is very close to the theoretical value given by the counting statistic and is better by a factor of 6 in comparison with previous conventional methods of calculation. We demonstrated that internal RSD (uncertainty) depends on regression coefficients of the linear function (R2). The typical internal precision of isotopic ratio measurements (0.003−0.02%) was achieved for δ202Hg when injecting as low as 90 pg of Hg species. With the new methodology, it is possible to (i) measure the isotopic composition when a sample and a bracketing standard have significantly different concentrations, (ii) measure the isotopic composition of different species in samples versus single species in a bracketing standard, and (iii) measure the isotopic ratios for low abundant isotopes. We demonstrated application of this method for different environmental samples and processes.
- 14 June 2010
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 82 (13) , 5652-5662
Approach to Measure Isotopic Ratios in Species Using Multicollector-ICPMS Coupled with Chromatography
A new approach was demonstrated for the isotope ratio measurement in different elemental species of Hg using transient signal obtained by chromatography coupled with multicollector-inductively coupled plasma mass spectrometry (MC-ICPMS). The method based on the slope of linear regression by transient intensities of different isotopes shows improved accuracy and reproducibility (0.2−0.5‰ as 2 standard deviation (SD)). Internal precision (RSD) of the method is very close to the theoretical value given by the counting statistic and is better by a factor of 6 in comparison with previous conventional methods of calculation. We demonstrated that internal RSD (uncertainty) depends on regression coefficients of the linear function (R2). The typical internal precision of isotopic ratio measurements (0.003−0.02%) was achieved for δ202Hg when injecting as low as 90 pg of Hg species. With the new methodology, it is possible to (i) measure the isotopic composition when a sample and a bracketing standard have significantly different concentrations, (ii) measure the isotopic composition of different species in samples versus single species in a bracketing standard, and (iii) measure the isotopic ratios for low abundant isotopes. We demonstrated application of this method for different environmental samples and processes.
- 11 April 2008
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 80 (10) , 3530-3538
Simultaneous Determination of Species-Specific Isotopic Composition of Hg by Gas Chromatography Coupled to Multicollector ICPMS
This work presents the simultaneous online determination of the isotopic composition of different Hg species in a single sample by the hyphenation of gas chromatography (GC) with multicollector-inductively coupled plasma mass spectrometry (MC-ICPMS). With the use of commercially available instrumentation, precise and accurate species-specific Hg isotope δ values (per mil deviation of the Hg isotope ratio in the sample relative to a reference standard) have been obtained online from consecutive GC transient signals. The use of isothermal temperature programs to extend the elution of the Hg species, the proper selection of the peak integration window, as well as the preconcentration of real samples are critical to provide optimal counting statistics. Also, isotope ratio drift during transient signal elution was overcome by introducing a mixed Hg(II) and MeHg standard bracketing scheme and expressing all results using the δ-notation relative to SRM NIST-3133. Using the proposed methodology, we have obtained an external 2SD precision of 0.56 ‰ for δ202Hg that is more than 10 times smaller than the overall Hg stable isotope variation thus far observed in terrestrial samples. The measurement of species-specific Hg isotopic composition relative to SRM NIST-3133 has been validated versus two other analytical techniques, i.e., conventional nebulization (CN) of Hg(II) solution and cold vapor (CV) generation of Hg0 vapor. A good agreement between the species-specific δ values obtained by the different techniques has been obtained in secondary fractionated reference standard (UM-Almadén) and environmental matrixes, i.e., BCR-CRM 464 (tuna fish) and IAEA-085 (human hair). The results show mass-dependent and mass-independent fractionation in environmental samples, i.e., mass-independent fractionation of odd isotopes 199Hg and 201Hg in tuna fish was observed. This methodology provides new possibilities for the future study of species-specific stable isotope geochemistry of Hg and other trace metals.
- 11 April 2008
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 80 (10) , 3530-3538
Simultaneous Determination of Species-Specific Isotopic Composition of Hg by Gas Chromatography Coupled to Multicollector ICPMS
This work presents the simultaneous online determination of the isotopic composition of different Hg species in a single sample by the hyphenation of gas chromatography (GC) with multicollector-inductively coupled plasma mass spectrometry (MC-ICPMS). With the use of commercially available instrumentation, precise and accurate species-specific Hg isotope δ values (per mil deviation of the Hg isotope ratio in the sample relative to a reference standard) have been obtained online from consecutive GC transient signals. The use of isothermal temperature programs to extend the elution of the Hg species, the proper selection of the peak integration window, as well as the preconcentration of real samples are critical to provide optimal counting statistics. Also, isotope ratio drift during transient signal elution was overcome by introducing a mixed Hg(II) and MeHg standard bracketing scheme and expressing all results using the δ-notation relative to SRM NIST-3133. Using the proposed methodology, we have obtained an external 2SD precision of 0.56 ‰ for δ202Hg that is more than 10 times smaller than the overall Hg stable isotope variation thus far observed in terrestrial samples. The measurement of species-specific Hg isotopic composition relative to SRM NIST-3133 has been validated versus two other analytical techniques, i.e., conventional nebulization (CN) of Hg(II) solution and cold vapor (CV) generation of Hg0 vapor. A good agreement between the species-specific δ values obtained by the different techniques has been obtained in secondary fractionated reference standard (UM-Almadén) and environmental matrixes, i.e., BCR-CRM 464 (tuna fish) and IAEA-085 (human hair). The results show mass-dependent and mass-independent fractionation in environmental samples, i.e., mass-independent fractionation of odd isotopes 199Hg and 201Hg in tuna fish was observed. This methodology provides new possibilities for the future study of species-specific stable isotope geochemistry of Hg and other trace metals.
- 19 June 2007
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 22 (9) , 1131-1137
Rapid fingerprinting of 239Pu and 240Pu in environmental samples with high U levels using on-line ion chromatography coupled with high-sensitivity quadrupole ICP-MS detection
A simple, rapid on-line analytical method for the determination of plutonium (Pu) isotopes in soil and sediment samples was developed. Microwave leaching was used to extract Pu from the major sample matrix. L-Ascorbic acid was found to be the most appropriate agent to convert all the Pu to Pu(IV) for chromatography. Flow injection chromatography using TEVA resin was optimized to separate, preconcentrate and elute Pu from other constituents of the sample including 238U. An APEX desolvation unit with a PEEK Mira Mist nebuliser was used to minimize clogging and hydride interferences. The advantage of using a high sensitivity quadrupole ICP-MS instrument for Pu detection was demonstrated. The detection limit was found to be 3 and 0.3 pg kg−1 for 239Pu and other Pu isotopes, respectively, which corresponds to a theoretical detection limit of ∼10 mBq kg−1 for 239+240Pu. To demonstrate the applicability of the method, Pu activities and atom ratios were measured for different sediments from the northern Asian region.
- 19 June 2007
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 22 (9) , 1131-1137
Rapid fingerprinting of 239Pu and 240Pu in environmental samples with high U levels using on-line ion chromatography coupled with high-sensitivity quadrupole ICP-MS detection
A simple, rapid on-line analytical method for the determination of plutonium (Pu) isotopes in soil and sediment samples was developed. Microwave leaching was used to extract Pu from the major sample matrix. L-Ascorbic acid was found to be the most appropriate agent to convert all the Pu to Pu(IV) for chromatography. Flow injection chromatography using TEVA resin was optimized to separate, preconcentrate and elute Pu from other constituents of the sample including 238U. An APEX desolvation unit with a PEEK Mira Mist nebuliser was used to minimize clogging and hydride interferences. The advantage of using a high sensitivity quadrupole ICP-MS instrument for Pu detection was demonstrated. The detection limit was found to be 3 and 0.3 pg kg−1 for 239Pu and other Pu isotopes, respectively, which corresponds to a theoretical detection limit of ∼10 mBq kg−1 for 239+240Pu. To demonstrate the applicability of the method, Pu activities and atom ratios were measured for different sediments from the northern Asian region.