Approach to Measure Isotopic Ratios in Species Using Multicollector-ICPMS Coupled with Chromatography
- 14 June 2010
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 82 (13) , 5652-5662
Abstract
A new approach was demonstrated for the isotope ratio measurement in different elemental species of Hg using transient signal obtained by chromatography coupled with multicollector-inductively coupled plasma mass spectrometry (MC-ICPMS). The method based on the slope of linear regression by transient intensities of different isotopes shows improved accuracy and reproducibility (0.2−0.5‰ as 2 standard deviation (SD)). Internal precision (RSD) of the method is very close to the theoretical value given by the counting statistic and is better by a factor of 6 in comparison with previous conventional methods of calculation. We demonstrated that internal RSD (uncertainty) depends on regression coefficients of the linear function (R2). The typical internal precision of isotopic ratio measurements (0.003−0.02%) was achieved for δ202Hg when injecting as low as 90 pg of Hg species. With the new methodology, it is possible to (i) measure the isotopic composition when a sample and a bracketing standard have significantly different concentrations, (ii) measure the isotopic composition of different species in samples versus single species in a bracketing standard, and (iii) measure the isotopic ratios for low abundant isotopes. We demonstrated application of this method for different environmental samples and processes.Keywords
This publication has 20 references indexed in Scilit:
- Compound-Specific δ34S Analysis of Volatile Organics by Coupled GC/Multicollector-ICPMSAnalytical Chemistry, 2009
- Determination of compound-specific Hg isotope ratios from transient signals using gas chromatography coupled to multicollector inductively coupled plasma mass spectrometry (MC-ICP/MS)Analytical and Bioanalytical Chemistry, 2008
- Simultaneous Determination of Species-Specific Isotopic Composition of Hg by Gas Chromatography Coupled to Multicollector ICPMSAnalytical Chemistry, 2008
- Compound‐specific 81 Br/ 79 Br analysis by capillary gas chromatography/multicollector inductively coupled plasma mass spectrometryRapid Communications in Mass Spectrometry, 2007
- GC/Multiple Collector-ICPMS Method for Chlorine Stable Isotope Analysis of Chlorinated Aliphatic HydrocarbonsAnalytical Chemistry, 2006
- High precision Hg isotope analysis of environmental samples using gold trap-MC-ICP-MSJournal of Analytical Atomic Spectrometry, 2005
- The development of multiple collector mass spectrometry for isotope ratio measurementsInternational Journal of Mass Spectrometry, 2005
- Measurement of high precision isotope ratios for mercury from coals using transient signalsJournal of Analytical Atomic Spectrometry, 2001
- Recent developments in inductively coupled plasma magnetic sector multiple collector mass spectrometryInternational Journal of Mass Spectrometry and Ion Processes, 1995
- The ICP as an ion source—origins, achievements and prospectsSpectrochimica Acta Part B: Atomic Spectroscopy, 1985