Christian J. L. Hermes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Christian J. L. Hermes has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Alexsandro dos Santos Silveira
POLO Laboratories—Cooling Systems Division, Department of Mechanical Engineering, Federal University of Santa Catarina, Florianópolis 88040-535, SC, Brazil
2 shared publications - Carlos A. R. Nascimento
LATAM System Engineering—Food Preservation, Electrolux do Brasil S.A., Curitiba 81520-620, PR, Brazil
2 shared publications - Andrew D. Sommers
Miami Univ, Dept Mech & Mfg Engn, Oxford, OH 45056 USA
1 shared publication - Dimitri Z. C. Silva
POLO Laboratories—Cooling Systems Division, Department of Mechanical Engineering, Federal University of Santa Catarina, Florianópolis 88040-535, SC, Brazil
1 shared publication Diogo L. da Silva
Federal University of Santa Catarina
1 shared publication- Diogo L. da Silva
Laboratory of Vehicular Refrigeration, Department of Mobility Engineering, Federal University of Santa Catarina, Joinville 89218-035, Brazil
1 shared publication
Latest Publications
- Open Access
Modeling of Non-Uniform Frost Accretion on ‘No-Frost’ Tube-Fin Evaporators
This study presents a transient two-dimensional model devised to predict frost build-up, pressure drop, and sensible and latent heat transfer rates in tube-fin evaporators, commonly used in ‘frost-free’ refrigerators. Based on the first principles of mass, momentum, and energy conservation for the airflow and the frost layer, the model accurately simulates evaporator blockage over time. Furthermore, it incorporates the interaction between the heat exchanger air-side impedance and the fan performance characteristic curve, using an iterative fluid-dynamic sub-model that predicts airflow reduction and redistribution in an evaporator with three fin densities. Frost accretion experiments were conducted using a purpose-built test setup consisting of a bottom-mount refrigerator cabinet maintained at controlled temperature and humidity in both the fresh and frozen-food compartments. Model validation demonstrated that the predicted results closely matched experimental observations. The results show that localized frost accumulation at fin density transitions causes severe airflow blockage, resulting in a 75% reduction in effective heat transfer area due to uneven air distribution. Finally, an analysis of two dimensionless competing indices demonstrates that fin density selection involves a critical trade-off between the initial cooling capacity and long-term frost resilience.
Open AccessModeling of Non-Uniform Frost Accretion on ‘No-Frost’ Tube-Fin Evaporators
This study presents a transient two-dimensional model devised to predict frost build-up, pressure drop, and sensible and latent heat transfer rates in tube-fin evaporators, commonly used in ‘frost-free’ refrigerators. Based on the first principles of mass, momentum, and energy conservation for the airflow and the frost layer, the model accurately simulates evaporator blockage over time. Furthermore, it incorporates the interaction between the heat exchanger air-side impedance and the fan performance characteristic curve, using an iterative fluid-dynamic sub-model that predicts airflow reduction and redistribution in an evaporator with three fin densities. Frost accretion experiments were conducted using a purpose-built test setup consisting of a bottom-mount refrigerator cabinet maintained at controlled temperature and humidity in both the fresh and frozen-food compartments. Model validation demonstrated that the predicted results closely matched experimental observations. The results show that localized frost accumulation at fin density transitions causes severe airflow blockage, resulting in a 75% reduction in effective heat transfer area due to uneven air distribution. Finally, an analysis of two dimensionless competing indices demonstrates that fin density selection involves a critical trade-off between the initial cooling capacity and long-term frost resilience.
- Open Access
Experimental Study of the Cross-Influence of Frost Morphology and Defrost Strategy on the Performance of Tube-Fin Evaporators of Household Refrigerators
This study is aimed at evaluating the combined influence of running conditions that affect frost morphology and defrost strategies on the thermal-fluid-dynamic performance of tube-fin ‘no-frost’ evaporators. To this end, two purpose-built experimental apparatuses were designed and constructed, one based upon a fully instrumented two-door bottom-mount ‘combi’ refrigerator with independent temperature and humidity control in both compartments, and another devised specifically for testing evaporator–heater assemblies under controlled frosting and defrosting cycles. Frost accumulation was studied for different surface temperatures and air humidity levels, revealing that higher humidity and lower surface temperatures led to lower frost density and thermal conductivity. Defrosting operations were analyzed for two different psychrometric conditions using three control strategies: step, ramp and pulse-width modulation (PWM). The ramp strategy yielded the highest defrost efficiency, reaching 36.7% in milder frost conditions, while the step strategy led to lower defrosting times. Such findings support the optimization of evaporator design and defrost strategies to improve energy efficiency in household refrigerating appliances.
Open AccessExperimental Study of the Cross-Influence of Frost Morphology and Defrost Strategy on the Performance of Tube-Fin Evaporators of Household Refrigerators
This study is aimed at evaluating the combined influence of running conditions that affect frost morphology and defrost strategies on the thermal-fluid-dynamic performance of tube-fin ‘no-frost’ evaporators. To this end, two purpose-built experimental apparatuses were designed and constructed, one based upon a fully instrumented two-door bottom-mount ‘combi’ refrigerator with independent temperature and humidity control in both compartments, and another devised specifically for testing evaporator–heater assemblies under controlled frosting and defrosting cycles. Frost accumulation was studied for different surface temperatures and air humidity levels, revealing that higher humidity and lower surface temperatures led to lower frost density and thermal conductivity. Defrosting operations were analyzed for two different psychrometric conditions using three control strategies: step, ramp and pulse-width modulation (PWM). The ramp strategy yielded the highest defrost efficiency, reaching 36.7% in milder frost conditions, while the step strategy led to lower defrosting times. Such findings support the optimization of evaporator design and defrost strategies to improve energy efficiency in household refrigerating appliances.
- Open Access
Evaporator Frosting in Refrigerating Appliances: Fundamentals and Applications
Modern refrigerators are equipped with fan-supplied evaporators often tailor-made to mitigate the impacts of frost accretion, not only in terms of frost blocking, which depletes the cooling capacity and therefore the refrigerator coefficient of performance (COP), but also to allow optimal defrosting, thereby avoiding the undesired consequences of condensate retention and additional thermal loads. Evaporator design for frosting conditions can be done either empirically through trial-and-error approaches or using simulation models suitable to predict the distribution of the frost mass along the finned coil. Albeit the former is mandatory for robustness verification prior to product approval, it has been advocated that the latter speeds up the design process and reduces the costs of the engineering undertaking. Therefore, this article is aimed at summarizing the required foundations for the design of efficient evaporators and defrosting systems with minimized performance impacts due to frosting. The thermodynamics, and the heat and mass transfer principles involved in the frost nucleation, growth, and densification phenomena are presented. The thermophysical properties of frost, such as density and thermal conductivity, are discussed, and their relationship with refrigeration operating conditions are established. A first-principles model is presented to predict the growth of the frost layer on the evaporator surface as a function of geometric and operating conditions. The relation between the microscopic properties of frost and their macroscopic effects on the evaporator thermo-hydraulic performance is established and confirmed with experimental evidence. Furthermore, different defrost strategies are compared, and the concept of optimal defrost is formulated. Finally, the results are used to analyze the efficiency of the defrost operation based on the net cooling capacity of the refrigeration system for different duty cycles and evaporator geometries.
Open AccessEvaporator Frosting in Refrigerating Appliances: Fundamentals and Applications
Modern refrigerators are equipped with fan-supplied evaporators often tailor-made to mitigate the impacts of frost accretion, not only in terms of frost blocking, which depletes the cooling capacity and therefore the refrigerator coefficient of performance (COP), but also to allow optimal defrosting, thereby avoiding the undesired consequences of condensate retention and additional thermal loads. Evaporator design for frosting conditions can be done either empirically through trial-and-error approaches or using simulation models suitable to predict the distribution of the frost mass along the finned coil. Albeit the former is mandatory for robustness verification prior to product approval, it has been advocated that the latter speeds up the design process and reduces the costs of the engineering undertaking. Therefore, this article is aimed at summarizing the required foundations for the design of efficient evaporators and defrosting systems with minimized performance impacts due to frosting. The thermodynamics, and the heat and mass transfer principles involved in the frost nucleation, growth, and densification phenomena are presented. The thermophysical properties of frost, such as density and thermal conductivity, are discussed, and their relationship with refrigeration operating conditions are established. A first-principles model is presented to predict the growth of the frost layer on the evaporator surface as a function of geometric and operating conditions. The relation between the microscopic properties of frost and their macroscopic effects on the evaporator thermo-hydraulic performance is established and confirmed with experimental evidence. Furthermore, different defrost strategies are compared, and the concept of optimal defrost is formulated. Finally, the results are used to analyze the efficiency of the defrost operation based on the net cooling capacity of the refrigeration system for different duty cycles and evaporator geometries.
- 12 September 2018
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 40 (10) , 479
Optimal design of fan-supplied tube-fin evaporators subjected to frosting conditions aiming at minimum energy consumption
- 12 September 2018
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 40 (10) , 479
Optimal design of fan-supplied tube-fin evaporators subjected to frosting conditions aiming at minimum energy consumption