Carlos A. R. Nascimento
Research Subjects
Carlos A. R. Nascimento has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Alexsandro dos Santos Silveira
POLO Laboratories—Cooling Systems Division, Department of Mechanical Engineering, Federal University of Santa Catarina, Florianópolis 88040-535, SC, Brazil
2 shared publications - Christian J. L. Hermes
POLO Laboratories—Cooling Systems Division, Department of Mechanical Engineering, Federal University of Santa Catarina, Florianópolis 88040-535, SC, Brazil
2 shared publications - Dimitri Z. C. Silva
POLO Laboratories—Cooling Systems Division, Department of Mechanical Engineering, Federal University of Santa Catarina, Florianópolis 88040-535, SC, Brazil
1 shared publication - Diogo Lôndero da Silva
Laboratory of Vehicular Refrigeration—ReVe, Department of Mobility Engineering, Federal University of Santa Catarina, Joinville 89219-600, SC, Brazil
1 shared publication - Luiz P. B. Braun
POLO Laboratories—Cooling Systems Division, Department of Mechanical Engineering, Federal University of Santa Catarina, Florianópolis 88040-535, SC, Brazil
1 shared publication - Rodrigo G. Reis
POLO Laboratories—Cooling Systems Division, Department of Mechanical Engineering, Federal University of Santa Catarina, Florianópolis 88040-535, SC, Brazil
1 shared publication
Latest Publications
- Open Access
Modeling of Non-Uniform Frost Accretion on ‘No-Frost’ Tube-Fin Evaporators
This study presents a transient two-dimensional model devised to predict frost build-up, pressure drop, and sensible and latent heat transfer rates in tube-fin evaporators, commonly used in ‘frost-free’ refrigerators. Based on the first principles of mass, momentum, and energy conservation for the airflow and the frost layer, the model accurately simulates evaporator blockage over time. Furthermore, it incorporates the interaction between the heat exchanger air-side impedance and the fan performance characteristic curve, using an iterative fluid-dynamic sub-model that predicts airflow reduction and redistribution in an evaporator with three fin densities. Frost accretion experiments were conducted using a purpose-built test setup consisting of a bottom-mount refrigerator cabinet maintained at controlled temperature and humidity in both the fresh and frozen-food compartments. Model validation demonstrated that the predicted results closely matched experimental observations. The results show that localized frost accumulation at fin density transitions causes severe airflow blockage, resulting in a 75% reduction in effective heat transfer area due to uneven air distribution. Finally, an analysis of two dimensionless competing indices demonstrates that fin density selection involves a critical trade-off between the initial cooling capacity and long-term frost resilience.
Open AccessModeling of Non-Uniform Frost Accretion on ‘No-Frost’ Tube-Fin Evaporators
This study presents a transient two-dimensional model devised to predict frost build-up, pressure drop, and sensible and latent heat transfer rates in tube-fin evaporators, commonly used in ‘frost-free’ refrigerators. Based on the first principles of mass, momentum, and energy conservation for the airflow and the frost layer, the model accurately simulates evaporator blockage over time. Furthermore, it incorporates the interaction between the heat exchanger air-side impedance and the fan performance characteristic curve, using an iterative fluid-dynamic sub-model that predicts airflow reduction and redistribution in an evaporator with three fin densities. Frost accretion experiments were conducted using a purpose-built test setup consisting of a bottom-mount refrigerator cabinet maintained at controlled temperature and humidity in both the fresh and frozen-food compartments. Model validation demonstrated that the predicted results closely matched experimental observations. The results show that localized frost accumulation at fin density transitions causes severe airflow blockage, resulting in a 75% reduction in effective heat transfer area due to uneven air distribution. Finally, an analysis of two dimensionless competing indices demonstrates that fin density selection involves a critical trade-off between the initial cooling capacity and long-term frost resilience.
- Open Access
Experimental Study of the Cross-Influence of Frost Morphology and Defrost Strategy on the Performance of Tube-Fin Evaporators of Household Refrigerators
This study is aimed at evaluating the combined influence of running conditions that affect frost morphology and defrost strategies on the thermal-fluid-dynamic performance of tube-fin ‘no-frost’ evaporators. To this end, two purpose-built experimental apparatuses were designed and constructed, one based upon a fully instrumented two-door bottom-mount ‘combi’ refrigerator with independent temperature and humidity control in both compartments, and another devised specifically for testing evaporator–heater assemblies under controlled frosting and defrosting cycles. Frost accumulation was studied for different surface temperatures and air humidity levels, revealing that higher humidity and lower surface temperatures led to lower frost density and thermal conductivity. Defrosting operations were analyzed for two different psychrometric conditions using three control strategies: step, ramp and pulse-width modulation (PWM). The ramp strategy yielded the highest defrost efficiency, reaching 36.7% in milder frost conditions, while the step strategy led to lower defrosting times. Such findings support the optimization of evaporator design and defrost strategies to improve energy efficiency in household refrigerating appliances.
Open AccessExperimental Study of the Cross-Influence of Frost Morphology and Defrost Strategy on the Performance of Tube-Fin Evaporators of Household Refrigerators
This study is aimed at evaluating the combined influence of running conditions that affect frost morphology and defrost strategies on the thermal-fluid-dynamic performance of tube-fin ‘no-frost’ evaporators. To this end, two purpose-built experimental apparatuses were designed and constructed, one based upon a fully instrumented two-door bottom-mount ‘combi’ refrigerator with independent temperature and humidity control in both compartments, and another devised specifically for testing evaporator–heater assemblies under controlled frosting and defrosting cycles. Frost accumulation was studied for different surface temperatures and air humidity levels, revealing that higher humidity and lower surface temperatures led to lower frost density and thermal conductivity. Defrosting operations were analyzed for two different psychrometric conditions using three control strategies: step, ramp and pulse-width modulation (PWM). The ramp strategy yielded the highest defrost efficiency, reaching 36.7% in milder frost conditions, while the step strategy led to lower defrosting times. Such findings support the optimization of evaporator design and defrost strategies to improve energy efficiency in household refrigerating appliances.