Aleksandra Grządziel
Research Subjects
Research Interests
Aleksandra Grządziel has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Krzysztof Ślosarek
Maria Sklodowska-Curie Institute – Oncology Center Gliwice Branch, Radiotherapy Planning Department, Gliwice, Poland
6 shared publicationsBarbara Bekman
Maria Sklodowska-Curie Institute – Oncology Center Gliwice Branch, Radiotherapy Planning Department, Gliwice, Poland
2 shared publications- Borislava Petrovic
Department of Radiotherapy, Institute of Oncology Vojvodina, Sremska Kamenica, Serbia
2 shared publications - Wojciech Osewski2 shared publications
Adam Bekman
Oncology Center Gliwice Branch, Medical Physics Department, Gliwice, Poland
1 shared publicationBarbara Smolińska
1 shared publication
Latest Publications
- 1 August 2018
- Published by Elsevier in Physica Medica
- Vol. 52, 142
[P149] Beam profile characteristic points designation for off-axis, wedged and FFF beams
- 1 August 2018
- Published by Elsevier in Physica Medica
- Vol. 52, 142
[P149] Beam profile characteristic points designation for off-axis, wedged and FFF beams
- Open Access
- 1 June 2016
- Published by Walter de Gruyter GmbH in Polish Journal of Medical Physics And Engineering
- Vol. 22 (2) , 35-40
Stereotactic radiosurgery of prostate cancer – dose distribution for VMAT and CyberKnife techniques
New capabilities of biomedical accelerators allow for very precise depositing of the radiation dose and imaging verification during the therapy. In addition, computer algorithms calculating dose distributions are taking into account the increasing number of physical effects. Therefore, administration of high dose fractionation, which is consistent with radiobiology used in oncology, becomes safer and safer. Stereotactic radiosurgery (SRS), which is very precise irradiation with high dose fractionation is increasingly widespread use in radiotherapy of prostate cancer. For this purpose different biomedical accelerators are used. The aim of this study is to compare dose distributions for two techniques: VMAT and CyberKnife. Statistical analysis was performed for the two groups of patients treated by VMAT technique (25 patients), and CyberKnife technique (15 patients). The analysis shows that the dose distributions are comparable, both in the treated area (prostate) and in the critical organs (rectum, urinary bladder, femoral heads). The results show that stereotactic radiosurgery of prostate cancer can be carried out on CyberKnife accelerator as well as on the classical accelerator with the use of VMAT technique.
- 1 June 2016
- Published by Walter de Gruyter GmbH in Polish Journal of Medical Physics And Engineering
- Vol. 22 (2) , 35-40
Open AccessStereotactic radiosurgery of prostate cancer – dose distribution for VMAT and CyberKnife techniques
New capabilities of biomedical accelerators allow for very precise depositing of the radiation dose and imaging verification during the therapy. In addition, computer algorithms calculating dose distributions are taking into account the increasing number of physical effects. Therefore, administration of high dose fractionation, which is consistent with radiobiology used in oncology, becomes safer and safer. Stereotactic radiosurgery (SRS), which is very precise irradiation with high dose fractionation is increasingly widespread use in radiotherapy of prostate cancer. For this purpose different biomedical accelerators are used. The aim of this study is to compare dose distributions for two techniques: VMAT and CyberKnife. Statistical analysis was performed for the two groups of patients treated by VMAT technique (25 patients), and CyberKnife technique (15 patients). The analysis shows that the dose distributions are comparable, both in the treated area (prostate) and in the critical organs (rectum, urinary bladder, femoral heads). The results show that stereotactic radiosurgery of prostate cancer can be carried out on CyberKnife accelerator as well as on the classical accelerator with the use of VMAT technique.
- 1 November 2013
- Published by Elsevier in Zeszyty Naukowe WCO, Letters in Oncology Science
- Vol. 10, 53
[Nr 97] Wybór metody napromieniania w zależności od lokalizacji obszaru leczenia
- 1 November 2013
- Published by Elsevier in Zeszyty Naukowe WCO, Letters in Oncology Science
- Vol. 10, 53
[Nr 97] Wybór metody napromieniania w zależności od lokalizacji obszaru leczenia
- Open Access
- 23 August 2013
- Published by Springer Nature in Radiation Oncology
- Vol. 8 (1) , 205
Robotic radiosurgery versus micro-multileaf collimator: a dosimetric comparison for large or critically located arteriovenous malformations
Stereotactic irradiation of large or critically located arteriovenous malformations (AVMs) is a special challenge for clinicians and radiation physicists. To date, no comprehensive comparison of two linac-based radiosurgery systems used for hypofractionated radiotherapy of large AVMs was published. The aim of the study was to compare dose distributions between CyberKnife (CK) system and linac with a micro-multileaf collimator (L-mMLC) in high-grade or critically located cerebral AVMs.
- 23 August 2013
- Published by Springer Nature in Radiation Oncology
- Vol. 8 (1) , 205
Open AccessRobotic radiosurgery versus micro-multileaf collimator: a dosimetric comparison for large or critically located arteriovenous malformations
Stereotactic irradiation of large or critically located arteriovenous malformations (AVMs) is a special challenge for clinicians and radiation physicists. To date, no comprehensive comparison of two linac-based radiosurgery systems used for hypofractionated radiotherapy of large AVMs was published. The aim of the study was to compare dose distributions between CyberKnife (CK) system and linac with a micro-multileaf collimator (L-mMLC) in high-grade or critically located cerebral AVMs.
- 13 February 2012
- Published by VM Media Group sp. z o.o in Reports of Practical Oncology and Radiotherapy
- Vol. 17 (2) , 97-103
Beam rate influence on dose distribution and fluence map in IMRT dynamic technique
To examine the impact of beam rate on dose distribution in IMRT plans and then to evaluate agreement of calculated and measured dose distributions for various beam rate values. Accelerators used in radiotherapy utilize some beam rate modes which can shorten irradiation time and thus reduce ability of patient movement during a treatment session. This aspect should be considered in high conformal dynamic techniques. Dose calculation was done for two different beam rates (100 MU/min and 600 MU/min) in an IMRT plan. For both, a comparison of Radiation Planning Index (RPI) and MU was conducted. Secondly, the comparison of optimal fluence maps and corresponding actual fluence maps was done. Next, actual fluence maps were measured and compared with the calculated ones. Gamma index was used for that assessment. Additionally, positions of each leaf of the MLC were controlled by home made software. Dose distribution obtained for lower beam rates was slightly better than for higher beam rates in terms of target coverage and risk structure protection. Lower numbers of MUs were achieved in 100 MU/min plans than in 600 MU/min plans. Actual fluence maps converted from optimal ones demonstrated more similarity in 100 MU/min plans. Better conformity of the measured maps to the calculated ones was obtained when a lower beam rate was applied. However, these differences were small. No correlation was found between quality of fluence map conversion and leaf motion accuracy. Execution of dynamic techniques is dependent on beam rate. However, these differences are minor. Analysis shows a slight superiority of a lower beam rate. It does not significantly affect treatment accuracy.
- 13 February 2012
- Published by VM Media Group sp. z o.o in Reports of Practical Oncology and Radiotherapy
- Vol. 17 (2) , 97-103
Beam rate influence on dose distribution and fluence map in IMRT dynamic technique
To examine the impact of beam rate on dose distribution in IMRT plans and then to evaluate agreement of calculated and measured dose distributions for various beam rate values. Accelerators used in radiotherapy utilize some beam rate modes which can shorten irradiation time and thus reduce ability of patient movement during a treatment session. This aspect should be considered in high conformal dynamic techniques. Dose calculation was done for two different beam rates (100 MU/min and 600 MU/min) in an IMRT plan. For both, a comparison of Radiation Planning Index (RPI) and MU was conducted. Secondly, the comparison of optimal fluence maps and corresponding actual fluence maps was done. Next, actual fluence maps were measured and compared with the calculated ones. Gamma index was used for that assessment. Additionally, positions of each leaf of the MLC were controlled by home made software. Dose distribution obtained for lower beam rates was slightly better than for higher beam rates in terms of target coverage and risk structure protection. Lower numbers of MUs were achieved in 100 MU/min plans than in 600 MU/min plans. Actual fluence maps converted from optimal ones demonstrated more similarity in 100 MU/min plans. Better conformity of the measured maps to the calculated ones was obtained when a lower beam rate was applied. However, these differences were small. No correlation was found between quality of fluence map conversion and leaf motion accuracy. Execution of dynamic techniques is dependent on beam rate. However, these differences are minor. Analysis shows a slight superiority of a lower beam rate. It does not significantly affect treatment accuracy.
- 1 January 2009
- Published by VM Media Group sp. z o.o in Reports of Practical Oncology and Radiotherapy
- Vol. 14 (1) , 5-10
Quality Assurance of TPS: comparison of dose calculation for stereotactic patients in Eclipse and iPlan RT Dose
SummaryBackgroundQuality assurance (QA) in the radiation therapy planning process is essential to ensure accurate dose delivery to the patient and to minimize the possibility of accidental exposure. In recent years, several reports have been developed addressing issues related to the commissioning and quality assurance (QA) of RTPSs.AimTo evaluate the differences between dose distributions obtained with different dose calculation algorithms implemented in TPSs for stereotactic irradiation.Materials and MethodsBrainLab's iPlan v. 3.0.2 RT Dose calculates by pencil beam algorithm, while Eclipse v.7.5.18 (Varian Medical Systems) calculates by different types of pencil beam/AAA algorithms (selectable).ResultsThe largest difference was found in the lung patient, where a difference of 10.3% in the number of monitor units and 8.3% in dose to the isocentre occurred (with calculation by AAA algorithm of Eclipse in relation to iPlan PB algorithm). The average difference in all other cases (AAA compared to iPlan) was 2.2% for MUs and 1.5% for dose to the isocentre. The average difference in all other cases (PB compared to iPlan) was 1.9% for MUs and 3.2% for dose to the isocentre. When data were transferred from iPlan through DICOM RT to Eclipse, for all patients an isocentre shift was observed.ConclusionThe dose distribution calculated by three different photon calculation algorithms results in clinically significant dose differences in isodose distribution, especially in the area of high inhomogeneities
- 1 January 2009
- Published by VM Media Group sp. z o.o in Reports of Practical Oncology and Radiotherapy
- Vol. 14 (1) , 5-10
Quality Assurance of TPS: comparison of dose calculation for stereotactic patients in Eclipse and iPlan RT Dose
SummaryBackgroundQuality assurance (QA) in the radiation therapy planning process is essential to ensure accurate dose delivery to the patient and to minimize the possibility of accidental exposure. In recent years, several reports have been developed addressing issues related to the commissioning and quality assurance (QA) of RTPSs.AimTo evaluate the differences between dose distributions obtained with different dose calculation algorithms implemented in TPSs for stereotactic irradiation.Materials and MethodsBrainLab's iPlan v. 3.0.2 RT Dose calculates by pencil beam algorithm, while Eclipse v.7.5.18 (Varian Medical Systems) calculates by different types of pencil beam/AAA algorithms (selectable).ResultsThe largest difference was found in the lung patient, where a difference of 10.3% in the number of monitor units and 8.3% in dose to the isocentre occurred (with calculation by AAA algorithm of Eclipse in relation to iPlan PB algorithm). The average difference in all other cases (AAA compared to iPlan) was 2.2% for MUs and 1.5% for dose to the isocentre. The average difference in all other cases (PB compared to iPlan) was 1.9% for MUs and 3.2% for dose to the isocentre. When data were transferred from iPlan through DICOM RT to Eclipse, for all patients an isocentre shift was observed.ConclusionThe dose distribution calculated by three different photon calculation algorithms results in clinically significant dose differences in isodose distribution, especially in the area of high inhomogeneities
- 1 November 2007
- Published by VM Media Group sp. z o.o in Reports of Practical Oncology and Radiotherapy
- Vol. 12 (6) , 307-312
EPID dosimetry – configuration and pre-treatment IMRT verification
SummaryBackgroundThe electronic portal imaging device (EPID) is used for patient setup during radiotherapy sessions. Dosimetric verification is done using ion chambers, diodes and thermoluminescence detectors. In intensity-modulated radiation therapy (IMRT) the dosimetry is a sophisticated and time-consuming task. The simultaneous use of amorphous silicon (aSi) detectors and the transit dosimetry (TD) option in the treatment planning system (TPS) (Eclipse, Varian) enables dosimetric pre-treatment verification of the IMRT plans.AimThe purpose of this study was to calibrate the EPID and TPS and to evaluate the usefulness of that method for dose verification in IMRT technique.Materials/MethodsThe first step was calibration of the aSi EPID mounted on three linear accelerators (Clianc23EXS, Varian). Afterwards, configuration of the calculation algorithm in TPS was carried out.Then dosimetric characteristics of the EPID were investigated. The EPID response depending on the beam mode, treatment time and static square field size was measured. The same measurements were repeated twice for three accelerators and analyzed.Additionally, three IMRT plans were treated for the pre-treatment dose evaluation. The calculated dose matrix was compared with the delivered one. The similarity of the calculated and measured fluency maps was evaluated by means of gamma index and score factor in Eclipse.ResultsThe linearity of the EPID signal was proven. For both beam modes EPID response is proportional to treatment time and field size, within the considered field size range.ConclusionsThe gamma evaluation indicates good correlation between predicted and acquired EPID image, although some differences in a high gradient area were found. We found the EPID-based pre-treatment IMRT verification method to be a good quality assurance (QA) procedure. Quite frequent control of the method and periodic recalibration of the used device are required
- 1 November 2007
- Published by VM Media Group sp. z o.o in Reports of Practical Oncology and Radiotherapy
- Vol. 12 (6) , 307-312
EPID dosimetry – configuration and pre-treatment IMRT verification
SummaryBackgroundThe electronic portal imaging device (EPID) is used for patient setup during radiotherapy sessions. Dosimetric verification is done using ion chambers, diodes and thermoluminescence detectors. In intensity-modulated radiation therapy (IMRT) the dosimetry is a sophisticated and time-consuming task. The simultaneous use of amorphous silicon (aSi) detectors and the transit dosimetry (TD) option in the treatment planning system (TPS) (Eclipse, Varian) enables dosimetric pre-treatment verification of the IMRT plans.AimThe purpose of this study was to calibrate the EPID and TPS and to evaluate the usefulness of that method for dose verification in IMRT technique.Materials/MethodsThe first step was calibration of the aSi EPID mounted on three linear accelerators (Clianc23EXS, Varian). Afterwards, configuration of the calculation algorithm in TPS was carried out.Then dosimetric characteristics of the EPID were investigated. The EPID response depending on the beam mode, treatment time and static square field size was measured. The same measurements were repeated twice for three accelerators and analyzed.Additionally, three IMRT plans were treated for the pre-treatment dose evaluation. The calculated dose matrix was compared with the delivered one. The similarity of the calculated and measured fluency maps was evaluated by means of gamma index and score factor in Eclipse.ResultsThe linearity of the EPID signal was proven. For both beam modes EPID response is proportional to treatment time and field size, within the considered field size range.ConclusionsThe gamma evaluation indicates good correlation between predicted and acquired EPID image, although some differences in a high gradient area were found. We found the EPID-based pre-treatment IMRT verification method to be a good quality assurance (QA) procedure. Quite frequent control of the method and periodic recalibration of the used device are required