Pierre Moussou
Research Subjects
Pierre Moussou has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Ch. Teygeman
Department of Materials and Mechanics of Components, EDF R&D, F-77818 Moret-sur-Loing, France
1 shared publication - G. Brasseur
Department of Analysis in Mechanics and Acoustics, EDF R&D, F-92141 Clamart, France
1 shared publication - Hassan Berro
Laboratoire de Mécanique, des Structures Industrielles, Durables (LaMSID), UMR EDF/CNRS/CEA 8193, 1, Avenue du General de Gaulle, Clamart 92141, France
1 shared publication - Jean-Francois Rit
EDF Lab − Les Renardières, Département matériaux et mécanique des composants, 77818 Orvanne, France
1 shared publication - Jerome Ferrari
Department of Materials and Mechanics of Components, EDF R&D, F-77818 Moret-sur-Loing, France
1 shared publication - Julien Berland
Laboratoire de Mécanique, des Structures Industrielles, Durables (LaMSID), UMR EDF/CNRS/CEA 8193, 1, Avenue du General de Gaulle, Clamart 92141, France
1 shared publication
Latest Publications
- 19 August 2014
- Published by ASME International in Journal of Pressure Vessel Technology
- Vol. 136 (5) , 051306
Forces Exerted on a Cylinder in Near-Axial Flow
This study investigates the flow around a cylinder in a near-axial flow at a Reynolds number of 27,000. Both computational fluid dynamics (CFD) calculations and experiments are performed. Time-mean values of lift force coefficient are investigated against the inclination of the cylinder in the domain of low inclinations (α = 5 deg. Numerical results for force and pressure show fair agreement with experiments for inclination below 5 deg and reveal that at low angles, the lift force is proportional to the angle. In the framework of a quasi-static approach, the instantaneous damping force exerted on a cylinder oscillating in axial flow is equivalent to the normal force exerted on a cylinder placed in an oblique flow.
- 19 August 2014
- Published by ASME International in Journal of Pressure Vessel Technology
- Vol. 136 (5) , 051306
Forces Exerted on a Cylinder in Near-Axial Flow
This study investigates the flow around a cylinder in a near-axial flow at a Reynolds number of 27,000. Both computational fluid dynamics (CFD) calculations and experiments are performed. Time-mean values of lift force coefficient are investigated against the inclination of the cylinder in the domain of low inclinations (α = 5 deg. Numerical results for force and pressure show fair agreement with experiments for inclination below 5 deg and reveal that at low angles, the lift force is proportional to the angle. In the framework of a quasi-static approach, the instantaneous damping force exerted on a cylinder oscillating in axial flow is equivalent to the normal force exerted on a cylinder placed in an oblique flow.
- 21 May 2013
- Published by ASME International in Journal of Pressure Vessel Technology
- Vol. 135 (3) , 030902
On the Coincidence of the Acoustical and Mechanical Natural Frequencies of a Pressure Vessel
A widespread conception among field engineers is that the coincidence of the structure and of the acoustic frequencies of a pressure vessel triggers a dramatic increase in the vibration level, leading to fatigue failure. The physics of fluid-structure interaction are revisited in order to clarify this effect, and a simple model of inertial coupling is proposed on the basis of one structure mode and one acoustic mode. It is shown that even if the uncoupled natural frequencies coincide, the coupled frequencies are split apart by an amount depending on the ratio of the fluid density and of the structure density, and on the spatial correlation of the fluid field. As a consequence, a large increase of the vibration level is more likely to occur in a gas system than in a liquid system. Illustrations based on dispersion equations are provided for cylindrical structures filled with vapor and water.
- 21 May 2013
- Published by ASME International in Journal of Pressure Vessel Technology
- Vol. 135 (3) , 030902
On the Coincidence of the Acoustical and Mechanical Natural Frequencies of a Pressure Vessel
A widespread conception among field engineers is that the coincidence of the structure and of the acoustic frequencies of a pressure vessel triggers a dramatic increase in the vibration level, leading to fatigue failure. The physics of fluid-structure interaction are revisited in order to clarify this effect, and a simple model of inertial coupling is proposed on the basis of one structure mode and one acoustic mode. It is shown that even if the uncoupled natural frequencies coincide, the coupled frequencies are split apart by an amount depending on the ratio of the fluid density and of the structure density, and on the spatial correlation of the fluid field. As a consequence, a large increase of the vibration level is more likely to occur in a gas system than in a liquid system. Illustrations based on dispersion equations are provided for cylindrical structures filled with vapor and water.
- 1 August 2010
- Published by ASME International in Journal of Pressure Vessel Technology
- Vol. 132 (4) , 041308
Instability of Pressure Relief Valves in Water Pipes
Pressure relief valves in water pipes are known to sometimes chatter when the inlet pressure slightly exceeds the set pressure. While these devices are responsible for numerous fatigue issues in process industries, there is a relatively low number of technical publications covering their performance, especially in heavy fluid applications. The present study is intended as a contribution to the understanding of pressure relief valve dynamics, taking into account fluid-structure interactions. A series of tests were performed with a water relief valve in a test rig. Adjusting the set pressure of the valve to about 30 bars, an upstream pressure varying from 20 bars to 35 bars was imposed, so that the valve opened and the water flow varied from a few to about . During the tests, the pipe was equipped upstream and downstream of the valve with static pressure sensors and a flowmeter, the disk lift was measured with a laser displacement sensor, and the spring force was recorded simultaneously. Several fluctuating pressure sensors were also installed in the inlet pipe. Static instability is investigated by comparing the spring force to the hydraulic force. Dynamic instability is observed and it is shown that the resonant behavior of the disk generates an apparent negative pressure drop coefficient at some frequencies. This negative pressure drop coefficient can trigger a dynamic instability in a manner similar to the negative damping effect in leakage-flow vibrations.- 1 August 2010
- Published by ASME International in Journal of Pressure Vessel Technology
- Vol. 132 (4) , 041308
Instability of Pressure Relief Valves in Water Pipes
Pressure relief valves in water pipes are known to sometimes chatter when the inlet pressure slightly exceeds the set pressure. While these devices are responsible for numerous fatigue issues in process industries, there is a relatively low number of technical publications covering their performance, especially in heavy fluid applications. The present study is intended as a contribution to the understanding of pressure relief valve dynamics, taking into account fluid-structure interactions. A series of tests were performed with a water relief valve in a test rig. Adjusting the set pressure of the valve to about 30 bars, an upstream pressure varying from 20 bars to 35 bars was imposed, so that the valve opened and the water flow varied from a few to about . During the tests, the pipe was equipped upstream and downstream of the valve with static pressure sensors and a flowmeter, the disk lift was measured with a laser displacement sensor, and the spring force was recorded simultaneously. Several fluctuating pressure sensors were also installed in the inlet pipe. Static instability is investigated by comparing the spring force to the hydraulic force. Dynamic instability is observed and it is shown that the resonant behavior of the disk generates an apparent negative pressure drop coefficient at some frequencies. This negative pressure drop coefficient can trigger a dynamic instability in a manner similar to the negative damping effect in leakage-flow vibrations.