Masanori Shinohara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Masanori Shinohara has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Shoji Takada
HTTR Reactor Engineering Section Department of HTTR Oarai Research and Development Center Sector of Nuclear Science Research Japan Atomic Energy Agency (JAEA)
5 shared publications - Kazuhiro Sawa
HTTR Reactor Engineering Section Department of HTTR Oarai Research and Development Center Sector of Nuclear Science Research Japan Atomic Energy Agency (JAEA)
4 shared publications - Yosuke Shimazaki
HTTR Reactor Engineering Section Department of HTTR Oarai Research and Development Center Sector of Nuclear Science Research Japan Atomic Energy Agency (JAEA)
4 shared publications - Daisuke Tochio
HTTR Reactor Engineering Section, Department of HTTR, Oarai Research and Development Center, Sector of Nuclear Science Research, Japan Atomic Energy Agency, Higashi-ibaraki-gun, Oarai 311-1393, Ibaraki, Japan
3 shared publications - Atsushi Shimizu
Department of HTTR, Oarai Research and Development Center, Sector of Nuclear Science Research, Japan Atomic Energy Agency, 4002 Narita-Cho, Higashi-ibarakigun, Oarai-machi 311-1393, Ibaraki, Japan
2 shared publications - Hiroaki Sawahata
Japan Atomic Energy Agency, 4002, Narita-cho, Oarai-machi, Higashiibaraki-gun, Ibaraki-ken 311-1393, Japan
2 shared publications
Latest Publications
- 31 July 2017
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 3 (4)
Loss of Core Cooling Test With One Cooling Line Inactive in Vessel Cooling System of High-Temperature Engineering Test Reactor
In the high-temperature engineering test reactor (HTTR), the vessel cooling system (VCS) which is arranged around the reactor pressure vessel (RPV) removes residual heat and decay heat from the reactor core when the forced core cooling is lost. The test of loss of forced cooling (LOFC) when one of two cooling lines in VCS lost its cooling function was carried out to simulate the partial loss of cooling function from the surface of RPV using the HTTR at the reactor thermal power of 9 MW, under the condition that the reactor power control system and the reactor inlet coolant temperature control system were isolated, and three helium gas circulators (HGCs) in the primary cooling system (PCS) were stopped. The test results showed that the reactor power immediately decreased to almost zero, which is caused by negative feedback effect of reactivity, and became stable as soon as HGCs were stopped. On the other hand, the temperature changes of permanent reflector block, RPV, and the biological shielding concrete were quite slow during the test. The temperature decrease of RPV was several degrees during the test. The numerical result showed a good agreement with the test result of temperature rise of biological shielding concrete around 1 °C by the numerical method that uses a calibrated thermal resistance by using the measured temperatures of RPV and the air outside of biological shielding concrete. The temperature increase of water cooling tube panel of VCS was calculated to be about 15 °C which is sufficiently small in the view point of property protection. It was confirmed that the sufficient cooling capacity of VCS can be maintained even in case that one of two water cooling lines of VCS loses its function.
- 31 July 2017
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 3 (4)
Loss of Core Cooling Test With One Cooling Line Inactive in Vessel Cooling System of High-Temperature Engineering Test Reactor
In the high-temperature engineering test reactor (HTTR), the vessel cooling system (VCS) which is arranged around the reactor pressure vessel (RPV) removes residual heat and decay heat from the reactor core when the forced core cooling is lost. The test of loss of forced cooling (LOFC) when one of two cooling lines in VCS lost its cooling function was carried out to simulate the partial loss of cooling function from the surface of RPV using the HTTR at the reactor thermal power of 9 MW, under the condition that the reactor power control system and the reactor inlet coolant temperature control system were isolated, and three helium gas circulators (HGCs) in the primary cooling system (PCS) were stopped. The test results showed that the reactor power immediately decreased to almost zero, which is caused by negative feedback effect of reactivity, and became stable as soon as HGCs were stopped. On the other hand, the temperature changes of permanent reflector block, RPV, and the biological shielding concrete were quite slow during the test. The temperature decrease of RPV was several degrees during the test. The numerical result showed a good agreement with the test result of temperature rise of biological shielding concrete around 1 °C by the numerical method that uses a calibrated thermal resistance by using the measured temperatures of RPV and the air outside of biological shielding concrete. The temperature increase of water cooling tube panel of VCS was calculated to be about 15 °C which is sufficiently small in the view point of property protection. It was confirmed that the sufficient cooling capacity of VCS can be maintained even in case that one of two water cooling lines of VCS loses its function.
- 12 October 2016
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 2 (4) , 044502
Investigation of Countermeasure Against Local Temperature Rise in Vessel Cooling System in Loss of Core Cooling Test Without Nuclear Heating
In the loss of core cooling test using High Temperature engineering Test Reactor (HTTR), the forced cooling of the reactor core is stopped without inserting control rods into the core and, furthermore, without cooling by the vessel cooling system (VCS) to verify safety evaluation codes to investigate the inherent safety of high-temperature gas-cooled reactor (HTGR) be secured by natural phenomena to make it possible to design a severe accident-free reactor. The VCS passively removes the retained residual heat and the decay heat from the core via the reactor pressure vessel (RPV) by natural convection and thermal radiation. In the test, the local temperature was supposed to exceed the limit from the viewpoint of long-term use at the uncovered water-cooling tube without thermal reflectors in the VCS, although the safety of reactor is kept. Through a cold test, which was carried out by non-nuclear heat input from helium gas circulators (HGCs) by stopping water flow in the VCS, the local higher temperature position was specified in the uncovered water-cooling tube of the VCS, although the temperature was sufficiently lower than the maximum allowable working temperature, and the natural circulation of water had an insufficient cooling effect on the temperature of the water-cooling tube below 1°C. Then, a new safe and secured procedure for the loss of core cooling test was established, which will be carried out soon after the restart of HTTR.
- 12 October 2016
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 2 (4) , 044502
Investigation of Countermeasure Against Local Temperature Rise in Vessel Cooling System in Loss of Core Cooling Test Without Nuclear Heating
In the loss of core cooling test using High Temperature engineering Test Reactor (HTTR), the forced cooling of the reactor core is stopped without inserting control rods into the core and, furthermore, without cooling by the vessel cooling system (VCS) to verify safety evaluation codes to investigate the inherent safety of high-temperature gas-cooled reactor (HTGR) be secured by natural phenomena to make it possible to design a severe accident-free reactor. The VCS passively removes the retained residual heat and the decay heat from the core via the reactor pressure vessel (RPV) by natural convection and thermal radiation. In the test, the local temperature was supposed to exceed the limit from the viewpoint of long-term use at the uncovered water-cooling tube without thermal reflectors in the VCS, although the safety of reactor is kept. Through a cold test, which was carried out by non-nuclear heat input from helium gas circulators (HGCs) by stopping water flow in the VCS, the local higher temperature position was specified in the uncovered water-cooling tube of the VCS, although the temperature was sufficiently lower than the maximum allowable working temperature, and the natural circulation of water had an insufficient cooling effect on the temperature of the water-cooling tube below 1°C. Then, a new safe and secured procedure for the loss of core cooling test was established, which will be carried out soon after the restart of HTTR.
- 12 October 2016
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 2 (4) , 041008
Development of the Prediction Technology of Cable Disconnection of In-Core Neutron Detector for the Future High-Temperature Gas-Cooled Reactors
Maintenance technologies for the reactor system have been developed by using the High Temperature engineering Test Reactor (HTTR). One of the important purposes of development is to accumulate the experiences and data to satisfy the availability of operation up to 90% by shortening the duration of the periodical maintenance for future high-temperature gas-cooled reactors (HTGRs) by shifting from time-based maintenance to condition-based maintenance. The technical issue of the maintenance of the in-core neutron detector, wide range monitor (WRM), is to predict the malfunction caused by cable disconnection to plan the replacement schedule. This is because it is difficult to observe directly inside the WRM in detail. The electrical inspection method was proposed to detect and predict the cable disconnection of the WRM by remote monitoring from outside the reactor using the time-domain reflectometry (TDR). The disconnection position, which was specified by the electrical method, was identified by nondestructive and destructive inspection. The accumulated data are expected to be contributed for advanced maintenance of future HTGRs.
- 12 October 2016
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 2 (4) , 041008
Development of the Prediction Technology of Cable Disconnection of In-Core Neutron Detector for the Future High-Temperature Gas-Cooled Reactors
Maintenance technologies for the reactor system have been developed by using the High Temperature engineering Test Reactor (HTTR). One of the important purposes of development is to accumulate the experiences and data to satisfy the availability of operation up to 90% by shortening the duration of the periodical maintenance for future high-temperature gas-cooled reactors (HTGRs) by shifting from time-based maintenance to condition-based maintenance. The technical issue of the maintenance of the in-core neutron detector, wide range monitor (WRM), is to predict the malfunction caused by cable disconnection to plan the replacement schedule. This is because it is difficult to observe directly inside the WRM in detail. The electrical inspection method was proposed to detect and predict the cable disconnection of the WRM by remote monitoring from outside the reactor using the time-domain reflectometry (TDR). The disconnection position, which was specified by the electrical method, was identified by nondestructive and destructive inspection. The accumulated data are expected to be contributed for advanced maintenance of future HTGRs.
- 1 January 2015
- Published by Japan Society of Mechanical Engineers in The Proceedings of the International Conference on Nuclear Engineering (ICONE)
- Vol. 2015.23, _ICONE23-1
ICONE23-1636 Investigation of Characteristics of Natural Circulation of Water in Vessel Cooling System in Loss of Core Cooling Test without Nuclear Heating
In the loss of forced core cooling test using High Temperature engineering Test Reactor (HTTR), the forced cooling of reactor core is stopped without inserting control rods into the core and cooling by Vessel Cooling System (VCS) to demonstrate the inherent safety of HTGR be secured by natural phenomena to make it possible to design a severe accident free reactor. The VCS passively removes the retained residual heat and the decay heat from the core via the reactor pressure vessel by natural convection and thermal radiation. In the test, the local temperature was supposed to exceed the limit from the viewpoint of long-term use at the uncovered water cooling tube by thermal reflectors in the VCS, although the safety of reactor is kept. Through a cold test, which was carried out by non-nuclear heat input from gas circulators with stopping water flow in the VCS, the local higher temperature position was specified although the temperature was sufficiently lower than the maximum allowable working temperature, and natural circulation of water had insufficient cooling effect on the temperature of water cooling tube below 1℃. Then, a new safe and secured procedure for the loss of forced core cooling test was established, which will be carried out soon after the restart of HTTR.
- 1 January 2015
- Published by Japan Society of Mechanical Engineers in The Proceedings of the International Conference on Nuclear Engineering (ICONE)
- Vol. 2015.23, _ICONE23-1
ICONE23-1636 Investigation of Characteristics of Natural Circulation of Water in Vessel Cooling System in Loss of Core Cooling Test without Nuclear Heating
In the loss of forced core cooling test using High Temperature engineering Test Reactor (HTTR), the forced cooling of reactor core is stopped without inserting control rods into the core and cooling by Vessel Cooling System (VCS) to demonstrate the inherent safety of HTGR be secured by natural phenomena to make it possible to design a severe accident free reactor. The VCS passively removes the retained residual heat and the decay heat from the core via the reactor pressure vessel by natural convection and thermal radiation. In the test, the local temperature was supposed to exceed the limit from the viewpoint of long-term use at the uncovered water cooling tube by thermal reflectors in the VCS, although the safety of reactor is kept. Through a cold test, which was carried out by non-nuclear heat input from gas circulators with stopping water flow in the VCS, the local higher temperature position was specified although the temperature was sufficiently lower than the maximum allowable working temperature, and natural circulation of water had insufficient cooling effect on the temperature of water cooling tube below 1℃. Then, a new safe and secured procedure for the loss of forced core cooling test was established, which will be carried out soon after the restart of HTTR.
- 1 January 2015
- Published by Japan Society of Mechanical Engineers in The Proceedings of the International Conference on Nuclear Engineering (ICONE)
- Vol. 2015.23, _ICONE23-1
ICONE23-1670 DEVELOPMENT OF THE PREDICTION TECHNOLOGY OF CABLE DISCONNECTION OF IN-CORE NEUTRON DETECTOR FOR THE FUTURE HIGH-TEMPERATURE GAS COOLED REACTORS
Maintenance technologies for the reactor system have been developed by using the high-temperature engineering test reactor (HTTR). One of the important purposes of development is to accumulate the experiences and data to satisfy the availability of operation up to 90% by shortening the duration of the periodical maintenance for the future HTGRs by shifting from the time-based maintenance to condition-based maintenance. The technical issue of the maintenance of in-core neutron detector, wide range monitor (WRM), is to predict the malfunction caused by cable disconnection to plan the replacement schedule. This is because that it is difficult to observe directly inside of the WRM in detail. The electrical inspection method was proposed to detect and predict the cable disconnection of the WRM by remote monitoring from outside of the reactor by using the time domain reflectometry and so on. The disconnection position, which was specified by the electrical method, was identified by non-destructive and destructive inspection. The accumulated data is expected to be contributed for advanced maintenance of future HTGRs.
- 1 January 2015
- Published by Japan Society of Mechanical Engineers in The Proceedings of the International Conference on Nuclear Engineering (ICONE)
- Vol. 2015.23, _ICONE23-1
ICONE23-1670 DEVELOPMENT OF THE PREDICTION TECHNOLOGY OF CABLE DISCONNECTION OF IN-CORE NEUTRON DETECTOR FOR THE FUTURE HIGH-TEMPERATURE GAS COOLED REACTORS
Maintenance technologies for the reactor system have been developed by using the high-temperature engineering test reactor (HTTR). One of the important purposes of development is to accumulate the experiences and data to satisfy the availability of operation up to 90% by shortening the duration of the periodical maintenance for the future HTGRs by shifting from the time-based maintenance to condition-based maintenance. The technical issue of the maintenance of in-core neutron detector, wide range monitor (WRM), is to predict the malfunction caused by cable disconnection to plan the replacement schedule. This is because that it is difficult to observe directly inside of the WRM in detail. The electrical inspection method was proposed to detect and predict the cable disconnection of the WRM by remote monitoring from outside of the reactor by using the time domain reflectometry and so on. The disconnection position, which was specified by the electrical method, was identified by non-destructive and destructive inspection. The accumulated data is expected to be contributed for advanced maintenance of future HTGRs.