Grazia Gambarini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Grazia Gambarini has a total of 143 co-authors. Here are the top co-authors by number of shared publications:
- Mauro Carrara
Medical Physics Unit, Fondazione IRCCS Istituto Nazionale Tumori, Milan, Italy
23 shared publications M. Borroni
11 shared publicationsA. Negri
INFN - Section of Milan, Italy
6 shared publications- Ladislav Viererbl
Centrum výzkumu Řež s.r.o
6 shared publications V. Klupak
Department of Neutron Physics, Research Centre Řež, Czech Republic
6 shared publicationsC. Tenconi
5 shared publications
Latest Publications
- 25 June 2020
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 53 (36) , 365003
Temperature behavior of radiochromic poly(vinyl-alcohol)-glutaraldehyde Fricke gel dosimeters in practice
The use of synthetic gel matrices prepared with poly(vinyl-alcohol) (PVA) cross-linked by glutaraldehyde (GTA) contributed to enhance the interest toward radiochromic Fricke gel (FG) dosimeters. As it occurs in several chemical dosimeters, the response of PVA-GTA Fricke gels could be affected by temperature. Aim of this work is to study the dependence of the dosimetric properties of PVA-GTA Fricke gel dosimeters both on the irradiation temperature and on temperature changes possibly occurring between the irradiation and readout phases. Such effects were investigated by means of magnetic resonance imaging and optical absorbance measurements. The results did not reveal any significant dependence of the sensitivity of the dosimeters on the irradiation temperature in the investigated interval 20–35 °C. By contrast, auto-oxidation phenomena confirmed to be a critical aspect for FG dosimeters, also in case of use of PVA matrix. The extent such phenomena, that might impair the accuracy of dose estimations, proved to critically depend on the temperature at which FG dosimeters are subjected before and after irradiation, as well as on the duration of possible thermal-stress.
- 25 June 2020
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 53 (36) , 365003
Temperature behavior of radiochromic poly(vinyl-alcohol)-glutaraldehyde Fricke gel dosimeters in practice
The use of synthetic gel matrices prepared with poly(vinyl-alcohol) (PVA) cross-linked by glutaraldehyde (GTA) contributed to enhance the interest toward radiochromic Fricke gel (FG) dosimeters. As it occurs in several chemical dosimeters, the response of PVA-GTA Fricke gels could be affected by temperature. Aim of this work is to study the dependence of the dosimetric properties of PVA-GTA Fricke gel dosimeters both on the irradiation temperature and on temperature changes possibly occurring between the irradiation and readout phases. Such effects were investigated by means of magnetic resonance imaging and optical absorbance measurements. The results did not reveal any significant dependence of the sensitivity of the dosimeters on the irradiation temperature in the investigated interval 20–35 °C. By contrast, auto-oxidation phenomena confirmed to be a critical aspect for FG dosimeters, also in case of use of PVA matrix. The extent such phenomena, that might impair the accuracy of dose estimations, proved to critically depend on the temperature at which FG dosimeters are subjected before and after irradiation, as well as on the duration of possible thermal-stress.
- 1 February 2019
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 155, 138-145
Development of a procedure for quenching-effect correction in images of absorbed dose from protons or carbon ions acquired with Gafchromic EBT3 films
- 1 February 2019
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 155, 138-145
Development of a procedure for quenching-effect correction in images of absorbed dose from protons or carbon ions acquired with Gafchromic EBT3 films
- Open Access
- 1 January 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1154 (1) , 012008
BNCT dosimetry: peculiarities and methods
Dosimetry in tissue exposed to the epithermal neutron beams utilized for BNCT is complex, due to the multiplicity of the possible neutron reactions and consequently of the secondary radiation that contains photons, charged particles and recoil nuclei. Owing to the different radiobiological effectiveness of the various components of the absorbed dose, it is necessary to attain the evaluation of each of them. In addition, the spatial distributions of these dose components changes considerably with size and shape of the irradiated volume. Therefore, BNCT dosimetry requires suitably developed calculations and experimental methods. In this work, Monte Carlo simulations in phantoms of different sizes and shapes have been developed. Experimental methods for separating the dose components, mainly based on gel dosimeters and thermoluminescence detectors, have been applied. Moreover, the change in the absorbed dose resulting from the addition of 157 Gd was investigated. Both measurements and calculations have been done with the BNCT epithermal beam of the LVR-15 reactor.
- 1 January 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1154 (1) , 012008
Open AccessBNCT dosimetry: peculiarities and methods
Dosimetry in tissue exposed to the epithermal neutron beams utilized for BNCT is complex, due to the multiplicity of the possible neutron reactions and consequently of the secondary radiation that contains photons, charged particles and recoil nuclei. Owing to the different radiobiological effectiveness of the various components of the absorbed dose, it is necessary to attain the evaluation of each of them. In addition, the spatial distributions of these dose components changes considerably with size and shape of the irradiated volume. Therefore, BNCT dosimetry requires suitably developed calculations and experimental methods. In this work, Monte Carlo simulations in phantoms of different sizes and shapes have been developed. Experimental methods for separating the dose components, mainly based on gel dosimeters and thermoluminescence detectors, have been applied. Moreover, the change in the absorbed dose resulting from the addition of 157 Gd was investigated. Both measurements and calculations have been done with the BNCT epithermal beam of the LVR-15 reactor.
- 21 August 2018
- Published by Elsevier in Radiation Measurements
- Vol. 119, 12-15
Study of fluence and dose spatial distributions in phantoms with various shapes exposed to epithermal neutrons for NCT
- 21 August 2018
- Published by Elsevier in Radiation Measurements
- Vol. 119, 12-15
Study of fluence and dose spatial distributions in phantoms with various shapes exposed to epithermal neutrons for NCT
- 1 August 2018
- Published by Elsevier in Physica Medica
- Vol. 52, 173-174
[P258] Optical absorbance properties of PVA-GTA Fricke gel dosimeters irradiated with 6 MV and 15 MV X-rays
- 1 August 2018
- Published by Elsevier in Physica Medica
- Vol. 52, 173-174
[P258] Optical absorbance properties of PVA-GTA Fricke gel dosimeters irradiated with 6 MV and 15 MV X-rays
- 1 August 2018
- Published by Elsevier in Physica Medica
- Vol. 52, 149-150
[P174] Study for the amendment of sensitivity quenching in carbon-ion dose images acquired with Gafchromic films
- 1 August 2018
- Published by Elsevier in Physica Medica
- Vol. 52, 149-150
[P174] Study for the amendment of sensitivity quenching in carbon-ion dose images acquired with Gafchromic films
- 20 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (9) , 2628-2632
Study on Characteristics of Fricke Xylenol Orange Gelatin Dosimeters
The response of Fricke xylenol orange gelatin dosimeter has been studied to investigate the possibility of achieving a calibration method based on a preirradiation procedure. With this aim, different preirradiation parameters have been tested, and the system response to subsequent irradiations has been investigated. Both Fricke gel layers and cuvettes were considered, and no dependence on shape and wall material was observed. An increase of the system response was observed, depending on the total absorbed dose and not on the number of subsequent irradiations performed, as evidenced by the changes of the absorption spectra shapes. Moreover, different calibration curves, and consequently different sensitivities, were obtained with different preirradiation parameters. In order to propose a calibration procedure, further studies are of fundamental importance to deeper comprehending the influence of preirradiation parameters on the system sensitivity and response. In particular, a systematic analysis of the whole absorption spectra has proved to be central.
- 20 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (9) , 2628-2632
Study on Characteristics of Fricke Xylenol Orange Gelatin Dosimeters
The response of Fricke xylenol orange gelatin dosimeter has been studied to investigate the possibility of achieving a calibration method based on a preirradiation procedure. With this aim, different preirradiation parameters have been tested, and the system response to subsequent irradiations has been investigated. Both Fricke gel layers and cuvettes were considered, and no dependence on shape and wall material was observed. An increase of the system response was observed, depending on the total absorbed dose and not on the number of subsequent irradiations performed, as evidenced by the changes of the absorption spectra shapes. Moreover, different calibration curves, and consequently different sensitivities, were obtained with different preirradiation parameters. In order to propose a calibration procedure, further studies are of fundamental importance to deeper comprehending the influence of preirradiation parameters on the system sensitivity and response. In particular, a systematic analysis of the whole absorption spectra has proved to be central.
- Open Access
- 1 September 2016
- Published by Elsevier in Physica Medica
- Vol. 32, 252
Low dose characterization of Fricke gel dosimeters by optical absorbance and MR relaxation methods
- 1 September 2016
- Published by Elsevier in Physica Medica
- Vol. 32, 252
Open AccessLow dose characterization of Fricke gel dosimeters by optical absorbance and MR relaxation methods
- Open Access
- 1 April 2016
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 119, S944
EP-1996: Post IVD verification and recalibration of MOSkins using a certified low dose emitting Sr-90 source
- 1 April 2016
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 119, S944
Open AccessEP-1996: Post IVD verification and recalibration of MOSkins using a certified low dose emitting Sr-90 source
- 1 February 2016
- Published by Elsevier in Physica Medica
- Vol. 32, 9-10
Development and application of a trans-rectal US probe integrated with MOSkin dosimeters: In vivo rectal wall measurements during HDR prostate brachytherapy
- 1 February 2016
- Published by Elsevier in Physica Medica
- Vol. 32, 9-10
Development and application of a trans-rectal US probe integrated with MOSkin dosimeters: In vivo rectal wall measurements during HDR prostate brachytherapy