Study on Characteristics of Fricke Xylenol Orange Gelatin Dosimeters
- 20 July 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (9) , 2628-2632
Abstract
The response of Fricke xylenol orange gelatin dosimeter has been studied to investigate the possibility of achieving a calibration method based on a preirradiation procedure. With this aim, different preirradiation parameters have been tested, and the system response to subsequent irradiations has been investigated. Both Fricke gel layers and cuvettes were considered, and no dependence on shape and wall material was observed. An increase of the system response was observed, depending on the total absorbed dose and not on the number of subsequent irradiations performed, as evidenced by the changes of the absorption spectra shapes. Moreover, different calibration curves, and consequently different sensitivities, were obtained with different preirradiation parameters. In order to propose a calibration procedure, further studies are of fundamental importance to deeper comprehending the influence of preirradiation parameters on the system sensitivity and response. In particular, a systematic analysis of the whole absorption spectra has proved to be central.Keywords
Funding Information
- Instituto Nazionale di Fisica Nucleare
- National Research Program of Relevant Interest, PRIN 2010 (2010SNALEM_002)
This publication has 12 references indexed in Scilit:
- True 3D chemical dosimetry (gels, plastics): Development and clinical roleJournal of Physics: Conference Series, 2015
- Study of Fricke gel dosimeter response for different gel qualityJournal of Physics: Conference Series, 2010
- Temperature dependence on the dose response of the Fricke–gelatin–xylenol orange gel dosimeterRadiation Physics and Chemistry, 2010
- An apparent threshold dose response in ferrous xylenol-orange gel dosimeters when scanned with a yellow light sourcePhysics in Medicine & Biology, 2008
- Study of light transmittance from layers of Fricke-xylenol-orange-gel dosimetersNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2004
- Review of Fricke gel dosimetersJournal of Physics: Conference Series, 2004
- Dose response of ferrous-xylenol orange gels: the effects of gel substrate, gelation time and dose fractionationJournal of Physics: Conference Series, 2004
- High resolution gel‐dosimetry by optical‐CT and MR scanningMedical Physics, 2001
- Imaging of radiation dose by visible color development in ferrous‐agarose‐xylenol orange gelsMedical Physics, 1991
- Measurement of radiation dose distributions by nuclear magnetic resonance (NMR) imagingPhysics in Medicine & Biology, 1984