  • Discarding the first of three nurse-auscultatory or oscillometric blood pressure measurements does not improve the association of office blood pressure with ABPM

    by John W. Graves, Brandon R. Grossardt

    Guidelines for office blood pressure (BP) measurements recommend two or more readings at each visit. It has been suggested that discarding the first reading may improve the diagnostic utility of office readings. We compare two methods of office BP measurement to determine whether discarding the first BP affects their association with ambulatory blood pressure monitoring (ABPM) readings. We studied measurements in 313 mildly hypertensive patients (181 men, median age 51 years) at the end of the washout phase of a hypertension treatment trial. All patients had three auscultatory readings by a trained nurse using a mercury manometer before a 24-h ABPM and three automated readings (Omron 705 CP) to American Heart Association standards after ABPM. Daytime ABPM (09:00-21:00) of systolic BP and diastolic BP were compared with office methods using first only, second and third only, and all three readings. Associations were assessed using Bland-Altman plots and Pearson's correlations. Bland-Altman plots revealed no differences between office methods and daytime ABPM regardless of whether the first reading was included or discarded. Results were similar for both systolic BP and diastolic BP. The Pearson correlations of office method readings with ABPM readings were lowest using the first measurement alone; however, discarding the first measurement did not improve the correlation compared with using all three readings. Discarding the first office BP reading does not change the association of office BP with ABPM or improve the correlation with ABPM values in hypertensive patients.


  • Open Access

    What is adequate hypertension control? Having your dinner and dessert too.

    by John W Graves

    Now that many options for treating hypertension are available and the studies of their use have proliferated, selecting a specific antihypertensive agent for a specific condition often receives an inordinate amount of attention from physicians. Controlling the blood pressure per se should be our primary concern ("dinner"), while choosing agents that may have added benefit in specific situations is secondary ("dessert").

  • Utility of ambulatory blood pressure monitoring in children and adolescents

    by John W. Graves, Mohammed Mahdi Althaf

    Diagnosis of hypertension is critically dependent on accurate blood pressure measurement. “Accurate” refers to carefully following the guidelines for blood pressure measurement laid out for children and adults to minimize observer and subject errors that commonly occur in clinical blood pressure measurement. Accurate blood pressure measurement is more important in children and adolescents as the misdiagnosis of hypertension may have a life-long adverse impact on insurability and employment. Automated blood pressure measurement offers multiple advantages in achieving high-quality blood pressure determinations by reducing observer errors. The most commonly used form of automated blood pressure measurement is 24-h ambulatory blood pressure measurement (ABPM). Information on ABPM in children has grown exponentially over the last decade. Normative data exists for diagnosis of hypertension in children using ABPM including a novel method for determining normal values with the LMS method. There is further information about the utility of different determinants of 24-h blood pressure such as dipping status, morning surge and blood pressure load. ABPM has been able to detect significant differences in blood pressure in many disease states in children including chronic renal failure, polycystic kidney disease, solitary functioning kidney, and after renal transplantation. Increasingly nonambulatory automated blood pressure determinations have been used in management of hypertension in children. Although nonambulatory automated readings lack information about nocturnal blood pressure or blood pressure during daily activity, studies have suggested that home automated blood pressure measurements are a helpful adjunct to the usual office blood pressure reading.


  • The trained observer better predicts daytime ABPM diastolic blood pressure in hypertensive patients than does an automated (Omron) device

    by John W. Graves, Brandon R. Grossardt, Rachel E. Gullerud, Kent R. Bailey, Jeffrey Feldstein

    Objectives Accurate blood pressure measurement is critical to successful clinical trials. Concerns about observer errors have led to the use of automated oscillometric devices without evidence that their performance is similar to that of trained observers. This study compares blood pressures obtained by trained observers and with an oscillometric device (Omron 705CP) to 24-h ambulatory blood pressure monitoring. Methods We performed a post-hoc analysis of 313 untreated hypertensive patients at the end of the washout phase of a Novartis hypertension trial. Patients had three seated trained observer mercury auscultatory blood pressure measurements followed by 24-h ambulatory blood pressure monitoring. The next day, the ambulatory blood pressure monitoring was removed and three seated readings were obtained with an Omron 705CP. Correlations for systolic blood pressure and diastolic blood pressure were obtained between daytime ambulatory blood pressure monitoring (0900 and 2100) and the two office methods. In addition, we investigated the degree of difference of trained observer and Omron measurements from ambulatory blood pressure monitoring. Results For systolic blood pressure, the correlation with ambulatory blood pressure monitoring of the trained observer was significantly better than with that of the Omron 705CP (0.641 vs. 0.555, P=0.01). For diastolic blood pressure values, even greater disparity between the two office method correlations with ambulatory blood pressure monitoring was observed (trained observer=0.593 vs. Omron=0.319, PPPP<0.0001 for systolic blood pressure and diastolic blood pressure). Conclusions For clinical trials using diastolic blood pressure targets, the Omron 705CP cannot replace the auscultatory blood pressure measurements of a trained observer. For systolic blood pressure, the Omron device and the trained observer had similar correlations with ambulatory blood pressure monitoring; however, both methods gave consistently higher systolic blood pressure values. Further study of oscillometric devices should be conducted before universally replacing auscultatory blood pressure determinations by trained observers in clinical trials.


  • Limited (6-h) ambulatory blood pressure monitoring is a valid replacement for the office blood pressure by trained nurse clinician in the diagnosis of hypertension

    by John W. Graves, Carol A. Nash, Diane E. Grill, Kent R. Bailey, Sheldon G. Sheps

    To assess the ability of limited ambulatory blood pressure monitoring as a valid replacement for office blood pressure measurement done to American Heart Association criteria in diagnosing hypertension. In all, 105 adults, who had been referred for limited ambulatory blood pressure monitoring, participated in the study. Limited ambulatory blood pressure monitoring consisted of 6 h of blood pressure measurement while ambulatory at the Mayo Clinic, using a SpaceLabs 90207 (SpaceLabs Medical, Issaquah, Washington, USA) collecting six readings per hour for the period of observation. The study participants gave consent for three additional consecutive office blood pressure measurements, using a validated aneroid device, done to American Heart Association criteria, by a single hypertension nurse specialist. Mean systolic blood pressure by limited ambulatory blood pressure monitoring was 137.9±14.2 mmHg and for the nurse, 137.9±20.1 mmHg. Mean diastolic blood pressure by limited ambulatory blood pressure monitoring was 81.5±9.7 mmHg and for the nurse, 74.3±11.9 mmHg. The intermethod difference for systolic blood pressure was 0.03±12.5 mmHg and diastolic blood pressure, –7.2±8.0 mmHg. Using <140/90 as criteria factor, limited ambulatory blood pressure monitoring and the trained nurse agreed 77% of the time on whether the patient was hypertensive. This agreement increased to 81% if the participant's referral blood pressure was ≥140/90. Limited ambulatory blood pressure monitoring is an excellent replacement for office blood pressure, done to American Heart Association criteria, in diagnosing hypertension. This avoids issues of variability introduced by the observers, such as digit preference and bias, and increases reproducibility of blood pressure measurements. The appropriate normal value for limited ambulatory blood pressure monitoring is <140/90 mmHg compared with <135/85 mmHg used in 24-h ambulatory blood pressure monitoring.


  • A survey of validated automated home blood pressure monitors available for the Internet shopper

    by John W. Graves

    Self-measurement of blood pressure using an automated home blood pressure monitoring (AHBPM) is increasingly used in hypertension management. Internet commerce increases dramatically each year. This study looked to identify the availability of validity of AHBPM and the correct cuff size to go with the AHBPM. Using the search engine ‘Google.com’, the author identified 124 consecutive unique sites offering at least one AHBPM. Validated AHBPM were those devices that had published studies showing that they had passed a recognized validation protocol. Each site was evaluated for all forms of sphygmomanometer, number of AHBPM, manual blood pressure devices, all cuff sizes available, additional cost of large adult cuff, number of validated AHBPM offered, and whether the site mentioned device validation. Of the 124 sites, 109 (81%) offered arm AHBPM and 66 (53%) offered one or more (range, 1–11) validated AHBPM. Only six of the 66 (9%) offering a validated AHBPM mentioned that fact; 58 of the 109 (53%) sites offering arm AHBPM offered more than one size of cuff; and 46 of the 58 (80%) charged extra for a large adult cuff (average $23.75, range, $4.80–98). Validated AHBPMs are readily available on the Internet. Currently, these sites do little to aid the consumer in purchasing a validated AHBPM. Large adult cuffs, commonly needed by hypertensive patients, are not always available for purchase. Charging extra for large adult cuffs is a potential hindrance to consumers purchasing the correct cuff size for accurate blood pressure measurement and should be eliminated.


  • The Accoson Greenlight 300???, the first non-automated mercury-free blood pressure measurement device to pass the International Protocol for blood pressure measuring devices in adults

    by John W. Graves, Mary Tibor, Blaithnead Murtagh, Lois Klein, Sheldon G. Sheps

    Accurate blood pressure measurement is critical to successful care of the hypertensive patient. The mercury manometer is rapidly being removed from clinical practice due to concerns about environmental contamination. The Accoson Greenlight 300™ device is the first non-automated mercury-free device for auscultatory blood pressure measurement to pass the International Protocol for validation of blood pressure measuring devices in adults. Fifty-one patients were enrolled to obtain the 33 patients required to fill the three systolic blood pressure (SBP) ranges (low 90–129 mmHg, medium 130–160 mmHg, high 161–180 mmHg) and diastolic blood pressure (DBP) ranges (low 40–79 mmHg, medium 80–100 mmHg, high 101–130 mmHg). Nine sequential blood pressure measurements by two observers with the mercury manometer and the supervisor with the Greenlight 300™ were taken. The first two observer blood pressures were used to classify the SBP and DBP range. The readings were then analyzed in two phases to determine whether the device passed the International Protocol. The device passed Phase 1 using 15 subjects. In Phase 2.1 (n = 33) for the 99 readings of SBP, 84 of 99 were within 5 mmHg, 95 of 99 were within 10 mmHg, and 98 of 99 were within 15 mmHg. For the 99 readings of DBP, 74 of 99 were within 5 mmHg, 90 of 99 were within 10 mmHg, and 96 of 99 were within 15 mmHg. In Phase 2.2 (n = 33) for SBP, 33 of 33 had 2 of 3 SBP within 5 mmHg and none had all three readings ≥ 5 mmHg. For DBP, 27 of 33 had 2 of 3 of their DBP within 5 mmHg and only three had all three readings ≥ 5 mmHg. The Accoson Greenlight 300™ is the first electronic non-automated blood pressure measurement device to pass the International Protocol.