  • Role of a Liquid Accumulator in a Passive Two-Phase Liquid Cooling System for Electronics: Experimental Analysis

    by Nicolas Lamaison, Raffaele Luca Amalfi, Todd Salamon, Jackson B. Marcinichen, John R. Thome

    Gravity-driven two-phase liquid cooling systems using flow boiling within microscale evaporators are becoming a game-changing solution for electronics cooling. The optimization of the system's filling ratio (FR) can however become a challenging problem for a system operating over a wide range of cooling capacities and temperature ranges. The benefits of a liquid accumulator (LA) to overcome this difficulty are evaluated in the present paper. An experimental thermosyphon cooling system was built to cool multiple electronic components up to a power dissipation of 1800 W. A double-ended cylinder with a volume of 150 cm3 is evaluated as the LA for two different system volumes (associated with two different condensers). Results demonstrated that the LA provided robust thermal performance as a function of FR for the entire range of heat loads tested. In addition, the present LA was more effective for a small volume system, 599 cm3, than for a large volume system, 1169 cm3, in which the relative size of the LA increased from 12.8% to 25% of the total system's volume.


  • Open Access

    Modeling of Two-Phase Evaporative Heat Transfer in Three-Dimensional Multicavity High Performance Microprocessor Chip Stacks

    by Yassir Madhour, Brian P. D'ENtremont, Jackson Braz Marcinichen, Bruno Michel, John Richard Thome

    Three-dimensional (3D) stacking of integrated-circuit (IC) dies increases system density and package functionality by vertically integrating two or more dies with area-array through-silicon-vias (TSVs). This reduces the length of global interconnects and the signal delay time and allows improvements in energy efficiency. However, the accumulation of heat fluxes and thermal interface resistances is a major limitation of vertically integrated packages. Scalable cooling solutions, such as two-phase interlayer cooling, will be required to extend 3D stacks beyond the most modest numbers of dies. This paper introduces a realistic 3D chip stack along with a simulation method for the heat spreading and flow distribution among the channels of the evaporators. The model includes the significant sensitivity of each channel's friction factor to vapor quality, and hence mass flow to heat flux, which characterizes parallel two-phase flows. Simulation cases explore various placements of hot spots within the stack and effects which are unique to two-phase interlayer cooling. The results show that the effect of hot spots on individual dies can be mitigated by strong interlayer heat conduction if the relative position of the hot spots is selected carefully to result in a heat load and flow which are well balanced laterally.


  • Two-Phase On-Chip Cooling Systems for Green Data Centers

    by John R. Thome, Jackson B. Marcinichen, Jonathan A. Olivier