  • Role of a Liquid Accumulator in a Passive Two-Phase Liquid Cooling System for Electronics: Experimental Analysis

    by Nicolas Lamaison, Raffaele Luca Amalfi, Todd Salamon, Jackson B. Marcinichen, John R. Thome

    Gravity-driven two-phase liquid cooling systems using flow boiling within microscale evaporators are becoming a game-changing solution for electronics cooling. The optimization of the system's filling ratio (FR) can however become a challenging problem for a system operating over a wide range of cooling capacities and temperature ranges. The benefits of a liquid accumulator (LA) to overcome this difficulty are evaluated in the present paper. An experimental thermosyphon cooling system was built to cool multiple electronic components up to a power dissipation of 1800 W. A double-ended cylinder with a volume of 150 cm3 is evaluated as the LA for two different system volumes (associated with two different condensers). Results demonstrated that the LA provided robust thermal performance as a function of FR for the entire range of heat loads tested. In addition, the present LA was more effective for a small volume system, 599 cm3, than for a large volume system, 1169 cm3, in which the relative size of the LA increased from 12.8% to 25% of the total system's volume.


  • Two-Phase Flow Control of Electronics Cooling With Pseudo-CPUs in Parallel Flow Circuits: Dynamic Modeling and Experimental Evaluation

    by Nicolas Lamaison, Jackson Braz Marcinichen, John Richard Thome

    On-chip two-phase cooling of parallel pseudo-CPUs integrated into a liquid pumped cooling cycle is modeled and experimentally verified versus a prototype test loop. The system's dynamic operation is studied since the heat dissipated by microprocessors is continuously changing during their operation and critical heat flux (CHF) conditions in the microevaporator must be avoided by flow control of the pump speed during heat load disturbances. The purpose here is to cool down multiple microprocessors in parallel and their auxiliary electronics (memories, dc/dc converters, etc.) to emulate datacenter servers with multiple CPUs. The dynamic simulation code was benchmarked using the test results obtained in an experimental facility consisting of a liquid pumped cooling cycle assembled in a test loop with two parallel microevaporators, which were evaluated under steady-state and transient conditions of balanced and unbalanced heat fluxes on the two pseudochips. The errors in the model's predictions of mean chip temperature and mixed exit vapor quality at steady state remained within ±10%. Transient comparisons showed that the trends and the time constants were satisfactorily respected. A case study considering four microprocessors cooled in parallel flow was then simulated for different levels of heat flux in the microprocessors (40, 30, 20, and 10 W cm−2), which showed the robustness of the predictive-corrective solver used. For a desired mixed vapor exit quality of 30%, at an inlet pressure and subcooling of 1600 kPa and 3 K, the resulting distribution of mass flow rate in the microevaporators was, respectively, 2.6, 2.9, 4.2, and 6.4 kg h−1 (mass fluxes of 47, 53, 76 and 116 kg m−2 s−1) and yielded approximately uniform chip temperatures (maximum variation of 2.6, 2, 1.7, and 0.7 K). The vapor quality and maximum chip temperature remained below the critical limits during both transient and steady-state regimes.