S. Murty Goddu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
S. Murty Goddu has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Daniel A. Low
2 shared publications- Daniel A. Low
Washington University School of Medicine, St. Louis, Missouri 63110, USA
2 shared publications - Eric E. Klein
Department of Radiation Oncology, Washington University, Saint Louis, MO, USA
2 shared publications Imran Zoberi
Washington University School of Medicine, MO, USA
2 shared publications- Issam El Naqa
Department of Machine Learning, Moffitt Cancer Center, Tampa, FL, United States
2 shared publications - Lakshmi Santanam
Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri 63110
2 shared publications
Latest Publications
- 2 October 2012
- Published by Wiley in Medical Physics
- Vol. 39 (10) , 6407-6419
The use of exit detector sinograms to detect anatomical variations for patients extending beyond the TomoTherapy field of view: A feasibility study
This work describes an independent method to use the TomoTherapy Hi-ART megavoltage CT imaging system for daily monitoring of anatomical changes of cancer patients whose anatomy extends beyond the imaging field of view. The imaging detector response to changes in attenuating media was measured using water-equivalent plastic. Weight loss was simulated using an anthropomorphic phantom and determining the system's ability to detect the weight loss. Layers of tissue-equivalent bolus were added to an anthropomorphic pelvis phantom and CT simulations of the phantom were conducted, one in which the phantom and bolus were both within the TomoTherapy imaging field of view, and another in which the couch was raised so that the bolus was outside the field of view. Gynecological treatment plans were developed using the TomoTherapy treatment planning system, and successive fractions of the plan were then delivered to the phantom. Weight loss was simulated by removing a 0.5 cm layer of bolus following each fraction. The exit detector sinograms were obtained from each fraction, and ratios of sinograms were calculated relative to a reference sinogram for which all bolus was in place. Histograms of ratio sinograms were determined and used to correlate with simulated weight loss. Exit detector sinograms and ratio histograms were also retrospectively analyzed for five patients all of whose anatomies extended beyond the imaging field of view and all of whom experienced weight variations exceeding 10% during treatment. Exit detector signal is well correlated to changes in attenuator thickness as demonstrated in both slab and anthropomorphic phantom geometries. Measured and expected signal increases agreed to within less than 2% for simulated weight loss on the anthropomorphic phantom. Exit detector signals for pelvic patients with significant weight loss variations were consistent with phantom measurements. The analysis of the ratio sinograms for the phantom measurements and real patients indicated that exit detector sinograms can be used to detect relative changes in patient anatomy for each fraction as a means of in vivo quality assurance.
- 2 October 2012
- Published by Wiley in Medical Physics
- Vol. 39 (10) , 6407-6419
The use of exit detector sinograms to detect anatomical variations for patients extending beyond the TomoTherapy field of view: A feasibility study
This work describes an independent method to use the TomoTherapy Hi-ART megavoltage CT imaging system for daily monitoring of anatomical changes of cancer patients whose anatomy extends beyond the imaging field of view. The imaging detector response to changes in attenuating media was measured using water-equivalent plastic. Weight loss was simulated using an anthropomorphic phantom and determining the system's ability to detect the weight loss. Layers of tissue-equivalent bolus were added to an anthropomorphic pelvis phantom and CT simulations of the phantom were conducted, one in which the phantom and bolus were both within the TomoTherapy imaging field of view, and another in which the couch was raised so that the bolus was outside the field of view. Gynecological treatment plans were developed using the TomoTherapy treatment planning system, and successive fractions of the plan were then delivered to the phantom. Weight loss was simulated by removing a 0.5 cm layer of bolus following each fraction. The exit detector sinograms were obtained from each fraction, and ratios of sinograms were calculated relative to a reference sinogram for which all bolus was in place. Histograms of ratio sinograms were determined and used to correlate with simulated weight loss. Exit detector sinograms and ratio histograms were also retrospectively analyzed for five patients all of whose anatomies extended beyond the imaging field of view and all of whom experienced weight variations exceeding 10% during treatment. Exit detector signal is well correlated to changes in attenuator thickness as demonstrated in both slab and anthropomorphic phantom geometries. Measured and expected signal increases agreed to within less than 2% for simulated weight loss on the anthropomorphic phantom. Exit detector signals for pelvic patients with significant weight loss variations were consistent with phantom measurements. The analysis of the ratio sinograms for the phantom measurements and real patients indicated that exit detector sinograms can be used to detect relative changes in patient anatomy for each fraction as a means of in vivo quality assurance.
- 31 October 2009
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 93 (1) , 64-70
Dosimetric consequences of uncorrected setup errors in helical Tomotherapy treatments of breast-cancer patients
- 31 October 2009
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 93 (1) , 64-70
Dosimetric consequences of uncorrected setup errors in helical Tomotherapy treatments of breast-cancer patients
- 1 September 2009
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (19) , 5663-5674
Enhanced efficiency in helical tomotherapy quality assurance using a custom-designed water-equivalent phantom
Tomotherapy is an image-guided, intensity-modulated radiation therapy system that delivers highly conformal dose distributions in a helical fashion. This system is also capable of acquiring megavoltage computed-tomography images and registering them to the planning kVCT images for accurate target localization. Quality assurance (QA) of this device is time intensive, but can be expedited by improved QA tools and procedures. A custom-designed phantom was fabricated to improve the efficiency of daily QA of our Tomotherapy machine. The phantom incorporates ionization chamber measurement points, plugs of different densities and slide-out film cartridges. The QA procedure was designed to verify in less than 30 min the vital components of the tomotherapy system: static beam quality and output, image quality, correctness of image registration and energy of the helical dose delivery. Machine output, percent depth dose and off-axis factors are simultaneously evaluated using a static 5 x 40 cm(2) open field. A single phantom scan is used to evaluate image quality and registration accuracy. The phantom can also be used for patient plan-specific QA. The QA results over a period of 6 months are reported in this paper. The QA process was found to be simple, efficient and capable of simultaneously verifying several important parameters.
- 1 September 2009
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (19) , 5663-5674
Enhanced efficiency in helical tomotherapy quality assurance using a custom-designed water-equivalent phantom
Tomotherapy is an image-guided, intensity-modulated radiation therapy system that delivers highly conformal dose distributions in a helical fashion. This system is also capable of acquiring megavoltage computed-tomography images and registering them to the planning kVCT images for accurate target localization. Quality assurance (QA) of this device is time intensive, but can be expedited by improved QA tools and procedures. A custom-designed phantom was fabricated to improve the efficiency of daily QA of our Tomotherapy machine. The phantom incorporates ionization chamber measurement points, plugs of different densities and slide-out film cartridges. The QA procedure was designed to verify in less than 30 min the vital components of the tomotherapy system: static beam quality and output, image quality, correctness of image registration and energy of the helical dose delivery. Machine output, percent depth dose and off-axis factors are simultaneously evaluated using a static 5 x 40 cm(2) open field. A single phantom scan is used to evaluate image quality and registration accuracy. The phantom can also be used for patient plan-specific QA. The QA results over a period of 6 months are reported in this paper. The QA process was found to be simple, efficient and capable of simultaneously verifying several important parameters.
- 1 August 2008
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 71 (5) , 1511-1517
Estimation of Setup Uncertainty Using Planar and MVCT Imaging for Gynecologic Malignancies
- 1 August 2008
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 71 (5) , 1511-1517
Estimation of Setup Uncertainty Using Planar and MVCT Imaging for Gynecologic Malignancies