Robert C. Block
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Robert C. Block has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
- Yaron Danon
Rensselaer Polytechnic Institute
8 shared publications - A. Daskalakis
Naval Nuclear Laboratory, Niskayuna, NY (United States)
5 shared publications - D. P. Barry
Naval Nuclear Laboratory, P.O. Box 1072, Schenectady, New York 12301-1072
5 shared publications G. Leinweber
Naval Nuclear Laboratory P.O. Box 1072, Schenectady, New York 12301-1072, USA
3 shared publications- Michael Rapp
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
3 shared publications A. Youmans
Rensselaer Polytechnic Institute, Gaerttner LINAC Center, 110 8th Street, Troy, New York 12180, USA
2 shared publications
Latest Publications
- 16 July 2025
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 224
A quasi-differential measurement of neutron scattering from tantalum between 0.65 MeV and 20 MeV
- 16 July 2025
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 224
A quasi-differential measurement of neutron scattering from tantalum between 0.65 MeV and 20 MeV
- Open Access
- 26 May 2023
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 284, 01016
Method to Compare Fission-to-Scattering Ratios using Uranium-238
A novel method was developed to separate the 238U fission contribution measured in quasi-differential time-of-flight scattering experiments in order to isolate the elastic and inelastic events. Pulse height distributions from in-beam measurements were used to generate response functions, which were used to reconstruct the 238U prompt fission neutron spectra. This method was validated by reconstructing the measured 252Cf spontaneous fission pulse height distribution. Monte Carlo calculations were used to model the experiment. Good agreement was observed between the measured and calculated 238U fission contribution.
- 26 May 2023
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 284, 01016
Open AccessMethod to Compare Fission-to-Scattering Ratios using Uranium-238
A novel method was developed to separate the 238U fission contribution measured in quasi-differential time-of-flight scattering experiments in order to isolate the elastic and inelastic events. Pulse height distributions from in-beam measurements were used to generate response functions, which were used to reconstruct the 238U prompt fission neutron spectra. This method was validated by reconstructing the measured 252Cf spontaneous fission pulse height distribution. Monte Carlo calculations were used to model the experiment. Good agreement was observed between the measured and calculated 238U fission contribution.
- Open Access
- 26 May 2023
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 284, 01019
Measurement of Photoneutron Yields Using the RPI LINAC and Assessment of Evaluated Photoneutron Data for Tantalum and Beryllium
A new experiment configuration was designed, developed, and implemented to measure photoneutron yields using the Rensselaer Polytechnic Institute (RPI) electron linear accelerator (LINAC) at the RPI Gaerttner LINAC Center. The experiment configuration includes a new target assembly that converts the LINAC electron beam into a high energy bremsstrahlung photon flux incident upon a sample material of interest. The photons excite nuclei in the sample of interest, which can subsequently emit neutrons (photoneutrons). The photoneutrons emitted in the direction of the detector system travel through a series of collimated vacuum pipes before reaching a pair of proton-recoil high-energy neutron detectors. The signals generated by the neutron detectors are processed using a digital data acquisition system and subsequently analyzed to determine the energy-dependent photoneutron yield from the sample of interest. The new experiment configuration was used to perform proof-of-concept experiments to measure the photoneutron yields from samples of tantalum and beryllium. The measured results were then compared against the results from Monte Carlo simulations of the detailed experiment configurations to perform preliminary assessments of evaluated photoneutron data libraries.
- 26 May 2023
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 284, 01019
Open AccessMeasurement of Photoneutron Yields Using the RPI LINAC and Assessment of Evaluated Photoneutron Data for Tantalum and Beryllium
A new experiment configuration was designed, developed, and implemented to measure photoneutron yields using the Rensselaer Polytechnic Institute (RPI) electron linear accelerator (LINAC) at the RPI Gaerttner LINAC Center. The experiment configuration includes a new target assembly that converts the LINAC electron beam into a high energy bremsstrahlung photon flux incident upon a sample material of interest. The photons excite nuclei in the sample of interest, which can subsequently emit neutrons (photoneutrons). The photoneutrons emitted in the direction of the detector system travel through a series of collimated vacuum pipes before reaching a pair of proton-recoil high-energy neutron detectors. The signals generated by the neutron detectors are processed using a digital data acquisition system and subsequently analyzed to determine the energy-dependent photoneutron yield from the sample of interest. The new experiment configuration was used to perform proof-of-concept experiments to measure the photoneutron yields from samples of tantalum and beryllium. The measured results were then compared against the results from Monte Carlo simulations of the detailed experiment configurations to perform preliminary assessments of evaluated photoneutron data libraries.
- Open Access
- 13 July 2017
- Published by American Physical Society (APS) in Physical Review C
- Vol. 96 (1) , 014607
() cross section and average resonance parameter measurements in the unresolved resonance region from 24 to 1180 keV using a filtered-beam techniqueA new array of four Deuterated Benzene () detectors has been installed at the Gaerttner Linear Accelerator Center at Rensselaer Polytechnic Institute for the purpose of measuring neutron capture cross sections in the keV region. Measurements were performed on samples of in the unresolved resonance region (URR) using a filtered-beam technique, by which a 30 cm iron filter was placed in a white-spectrum neutron beam to remove all time-dependent -ray background and all neutrons except those transmitted through resonance-potential interference “windows” in the iron. The resulting filtered beam was effectively a quasimonoenergetic neutron source, which was used for performing measurements on isotopes with narrow level spacings in the URR. The capture cross-section results obtained for two thicknesses of tantalum are in agreement with those documented in the JEFF-3.2 library, as are the average resonance parameters obtained via a fit to the data using the sammy-fitacs code.- 13 July 2017
- Published by American Physical Society (APS) in Physical Review C
- Vol. 96 (1) , 014607
Open Access() cross section and average resonance parameter measurements in the unresolved resonance region from 24 to 1180 keV using a filtered-beam techniqueA new array of four Deuterated Benzene () detectors has been installed at the Gaerttner Linear Accelerator Center at Rensselaer Polytechnic Institute for the purpose of measuring neutron capture cross sections in the keV region. Measurements were performed on samples of in the unresolved resonance region (URR) using a filtered-beam technique, by which a 30 cm iron filter was placed in a white-spectrum neutron beam to remove all time-dependent -ray background and all neutrons except those transmitted through resonance-potential interference “windows” in the iron. The resulting filtered beam was effectively a quasimonoenergetic neutron source, which was used for performing measurements on isotopes with narrow level spacings in the URR. The capture cross-section results obtained for two thicknesses of tantalum are in agreement with those documented in the JEFF-3.2 library, as are the average resonance parameters obtained via a fit to the data using the sammy-fitacs code. - Open Access
- 30 June 2017
- Published by American Physical Society (APS) in Physical Review C
- Vol. 95 (6) , 064615
Measurement of prompt fission neutron spectrum for spontaneous fission of using multiplicity taggingThe prompt fission neutron spectrum from spontaneous fission of is an integral part of several aspects of nuclear data. Not only is the spectrum itself of interest, but neutron detectors often use the spectrum for calibration, and other prompt fission neutron spectra are measured as a ratio to . Therefore, reducing the uncertainties in this spectrum will allow for more accurate nuclear data to be available across a wide range of fields. The prompt fission neutron spectrum for the spontaneous fission of was measured at Rensselaer Polytechnic Institute using the multiple tagging method with a 18.4-ng fission sample. An EJ-301 liquid scintillator fast neutron detector was used to measure the high energy portion of the spectrum, 0.5–7 MeV, and a thin EJ-204 plastic scintillator was used to measure the low energy portion of the spectrum, from 50 keV to 2 MeV. These spectra both show good agreement with the current evaluation of and have low associated uncertainties providing a new high precision measurement that helps reduce the uncertainties in the prompt fission neutron spectrum for the spontaneous fission of .- 30 June 2017
- Published by American Physical Society (APS) in Physical Review C
- Vol. 95 (6) , 064615
Open AccessMeasurement of prompt fission neutron spectrum for spontaneous fission of using multiplicity taggingThe prompt fission neutron spectrum from spontaneous fission of is an integral part of several aspects of nuclear data. Not only is the spectrum itself of interest, but neutron detectors often use the spectrum for calibration, and other prompt fission neutron spectra are measured as a ratio to . Therefore, reducing the uncertainties in this spectrum will allow for more accurate nuclear data to be available across a wide range of fields. The prompt fission neutron spectrum for the spontaneous fission of was measured at Rensselaer Polytechnic Institute using the multiple tagging method with a 18.4-ng fission sample. An EJ-301 liquid scintillator fast neutron detector was used to measure the high energy portion of the spectrum, 0.5–7 MeV, and a thin EJ-204 plastic scintillator was used to measure the low energy portion of the spectrum, from 50 keV to 2 MeV. These spectra both show good agreement with the current evaluation of and have low associated uncertainties providing a new high precision measurement that helps reduce the uncertainties in the prompt fission neutron spectrum for the spontaneous fission of . - 1 January 2017
- Published by Elsevier in Progress in Nuclear Energy
- Vol. 94, 126-132
Neutron transmission and capture measurements and analysis of Dy from 0.01 to 550 eV
- 1 January 2017
- Published by Elsevier in Progress in Nuclear Energy
- Vol. 94, 126-132
Neutron transmission and capture measurements and analysis of Dy from 0.01 to 550 eV
- 6 February 2007
- Published by Office of Scientific and Technical Information (OSTI)
Hafnium Resonance Parameter Analysis Using Neutron Capture and Transmission Experiments
The focus of this work is to determine the resonance parameters for stable hafnium isotopes in the 0.005 - 200 eV region, with special emphasis on the overlapping {sup 176}Hf and {sup 178}Hf resonances near 8 eV. Accurate hafnium cross sections and resonance parameters are needed in order to quantify the effects of hafnium found in zirconium, a metal commonly used in reactors. The accuracy of the cross sections and the corresponding resonance parameters used in current nuclear analysis tools are rapidly becoming the limiting factor in reducing the overall uncertainty on reactor physics calculations. Experiments measuring neutron capture and transmission are routinely performed at the Rensselaer Polytechnic Institute (RPI) LINAC using the time-of flight technique. {sup 6}Li glass scintillation detectors were used for transmission experiments at flight path lengths of 15 and 25 m, respectively. Capture experiments were performed using a sixteen section NaI multiplicity detector at a flight path length of 25 m. These experiments utilized several thicknesses of metallic and isotope-enriched liquid Hf samples. The liquid Hf samples were designed to provide information on the {sup 176}Hf and {sup 178}Hf contributions to the 8 eV doublet without saturation. Data analyses were performed using the R-matrix Bayesian codemore » SAMMY. A combined capture and transmission data analysis yielded resonance parameters for all hafnium isotopes from 0.005 - 200 eV. Additionally, resonance integrals were calculated, along with errors for each hafnium isotope, using the NJOY and INTER codes. The isotopic resonance integrals calculated were significantly different than previous values. The {sup 176}Hf resonance integral, based on this work, is approximately 73% higher than the ENDF/B-VI value. This is due primarily to the changes to resonance parameters in the 8 eV resonance, the neutron width presented in this work is more than twice that of the previous value. The calculated elemental hafnium resonance integral however, changed very little. « less
- 6 February 2007
- Published by Office of Scientific and Technical Information (OSTI)
Hafnium Resonance Parameter Analysis Using Neutron Capture and Transmission Experiments
The focus of this work is to determine the resonance parameters for stable hafnium isotopes in the 0.005 - 200 eV region, with special emphasis on the overlapping {sup 176}Hf and {sup 178}Hf resonances near 8 eV. Accurate hafnium cross sections and resonance parameters are needed in order to quantify the effects of hafnium found in zirconium, a metal commonly used in reactors. The accuracy of the cross sections and the corresponding resonance parameters used in current nuclear analysis tools are rapidly becoming the limiting factor in reducing the overall uncertainty on reactor physics calculations. Experiments measuring neutron capture and transmission are routinely performed at the Rensselaer Polytechnic Institute (RPI) LINAC using the time-of flight technique. {sup 6}Li glass scintillation detectors were used for transmission experiments at flight path lengths of 15 and 25 m, respectively. Capture experiments were performed using a sixteen section NaI multiplicity detector at a flight path length of 25 m. These experiments utilized several thicknesses of metallic and isotope-enriched liquid Hf samples. The liquid Hf samples were designed to provide information on the {sup 176}Hf and {sup 178}Hf contributions to the 8 eV doublet without saturation. Data analyses were performed using the R-matrix Bayesian codemore » SAMMY. A combined capture and transmission data analysis yielded resonance parameters for all hafnium isotopes from 0.005 - 200 eV. Additionally, resonance integrals were calculated, along with errors for each hafnium isotope, using the NJOY and INTER codes. The isotopic resonance integrals calculated were significantly different than previous values. The {sup 176}Hf resonance integral, based on this work, is approximately 73% higher than the ENDF/B-VI value. This is due primarily to the changes to resonance parameters in the 8 eV resonance, the neutron width presented in this work is more than twice that of the previous value. The calculated elemental hafnium resonance integral however, changed very little. « less
- Open Access
- 2 May 2006
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 96 (17) , 179903
Erratum: Nuclear Emissions during Self-Nucleated Acoustic Cavitation [Phys. Rev. Lett.96, 034301 (2006)]
DOI: https://doi.org/10.1103/PhysRevLett.96.179903
- 2 May 2006
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 96 (17) , 179903
Open AccessErratum: Nuclear Emissions during Self-Nucleated Acoustic Cavitation [Phys. Rev. Lett.96, 034301 (2006)]
DOI: https://doi.org/10.1103/PhysRevLett.96.179903
- 30 November 2004
- Published by Office of Scientific and Technical Information (OSTI)
Development of a Novel Tunable X-Ray Source for the RPI-LINAC
This document summarizes the results of a three year effort to develop a parametric x-ray (PXR) source. The emphasis of this research was to demonstrate production of high yield monoenergetic x-rays. Production of PXR is accomplished by placing a crystal in a relativistic electron beam. The process was first demonstrated in 1985 in Russia. Numerous papers were written about the characteristics of PXR from both experimental and theoretical perspectives. The advantage of PXR over other monoenergetic x-ray sources is that it is produced at large angle relative to the electron beam and at high intensity. None of the previous work described in the literature capitalized on this effect to study what is required in order to generate an effective monoenergetic x-ray source that can be used for practical applications. The work summarized here describes the process done in order to optimize the PXR production process by selecting an appropriate crystal and the optimal conditions. The research focused on production of 18 keV x-rays which are suitable for mammography however the results are not limited to this application or energy range. We are the first group to demonstrate x-ray imaging using PXR. Such sources can improve current medical imaging modalities. Moremore » research is required in order to design a prototype of a compact source.« less
- 30 November 2004
- Published by Office of Scientific and Technical Information (OSTI)
Development of a Novel Tunable X-Ray Source for the RPI-LINAC
This document summarizes the results of a three year effort to develop a parametric x-ray (PXR) source. The emphasis of this research was to demonstrate production of high yield monoenergetic x-rays. Production of PXR is accomplished by placing a crystal in a relativistic electron beam. The process was first demonstrated in 1985 in Russia. Numerous papers were written about the characteristics of PXR from both experimental and theoretical perspectives. The advantage of PXR over other monoenergetic x-ray sources is that it is produced at large angle relative to the electron beam and at high intensity. None of the previous work described in the literature capitalized on this effect to study what is required in order to generate an effective monoenergetic x-ray source that can be used for practical applications. The work summarized here describes the process done in order to optimize the PXR production process by selecting an appropriate crystal and the optimal conditions. The research focused on production of 18 keV x-rays which are suitable for mammography however the results are not limited to this application or energy range. We are the first group to demonstrate x-ray imaging using PXR. Such sources can improve current medical imaging modalities. Moremore » research is required in order to design a prototype of a compact source.« less
- 21 May 2002
- Published by Wiley in ChemInform
- Vol. 33 (21)
ChemInform Abstract: Evidence for Nuclear Emissions During Acoustic Cavitation.
ChemInform is a weekly Abstracting Service, delivering concise information at a glance that was extracted from about 100 leading journals. To access a ChemInform Abstract of an article which was published elsewhere, please select a “Full Text” option. The original article is trackable via the “References” option.
- 21 May 2002
- Published by Wiley in ChemInform
- Vol. 33 (21)
ChemInform Abstract: Evidence for Nuclear Emissions During Acoustic Cavitation.
ChemInform is a weekly Abstracting Service, delivering concise information at a glance that was extracted from about 100 leading journals. To access a ChemInform Abstract of an article which was published elsewhere, please select a “Full Text” option. The original article is trackable via the “References” option.