MRMichael Rapp

Michael Rapp

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Michael Rapp has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A quasi-differential measurement of neutron scattering from tantalum between 0.65 MeV and 20 MeV

    by Gregory J. Siemers, Yaron Danon, Sukhjinder Singh, Katelyn C. Keparutis, Peter J. Brain, Benjamin H. Wang, Adam M. Daskalakis, Devin P. Barry, Michael J. Rapp, Robert C. Block


  • Open Access

    Quasi-Differential Neutron Scattering Measurements of 181Ta and Teflon from 1.5 to 20 MeV [Slides]

    by Gregory Siemers, S. Singh, Y. Danon, A. Daskalakis, K. Cook, B. Wang, P. Wang, M. Rapp

    This presentation covers motivation for the Experiments Performed. Secondly, it touches on upgrades to the Experimental Apparatus for Measurements. Thirdly, it presents quasi-Differential Experimental Methodology a) Pulse Shape Discrimination b) Validation Measurement of Carbon. The presentation concludes with Preliminary Results and Future Studies.


  • Open Access

    Neutron Capture and Transmission Measurements of 54Fe at the RPI LINAC

    by Sukhjinder Singh, Yaron Danon, Adam Ney, Katelyn C. Cook, Dominik Fritz, Benjamin Wang, Peter Brain, A. Daskalakis, Michael Rapp

    54Fe radiative capture cross section and transmission measurements were conducted at the Rensselaer Polytechnic Institute (RPI) Gaerttner Linear Accelerator (LINAC) Center using an enriched 54Fe sample in the keV energy region. 54Fe is a constituent of natural iron, which is present in a large variety of nuclear grade materials. Therefore, it is important to have an accurate understanding of the cross sections of 54Fe, which can be measured experimentally. In the time-of-flight measurements conducted at the LINAC, an array of four C6D6 detectors surrounded the sample and radiative capture data were collected using a digital data acquisition system. Additionally, a Li-glass detector was used to collect transmission data using an analog data acquisition system. The radiative capture yield of the 54Fe measurements were normalized to saturated resonances observed in Au and Ta to obtain an absolute capture yield. The preliminary capture yield and preliminary transmission obtained can be compared to evaluations and existing experimental data. Some disagreements were observed in prominent d-wave capture resonances observed in 54Fe in the low-keV neutron energy region. Both sets of experimental data along with pre-existing datasets will greatly enhance RPI’s ability to perform resonance evaluation for 54Fe up to roughly 1 MeV.


  • Open Access

    Method to Compare Fission-to-Scattering Ratios using Uranium-238

    by A. Daskalakis, Amanda M. Lewis, Michael Rapp, D. P. Barry, Ezekiel Blain, R.C. Block, Yaron Danon

    A novel method was developed to separate the 238U fission contribution measured in quasi-differential time-of-flight scattering experiments in order to isolate the elastic and inelastic events. Pulse height distributions from in-beam measurements were used to generate response functions, which were used to reconstruct the 238U prompt fission neutron spectra. This method was validated by reconstructing the measured 252Cf spontaneous fission pulse height distribution. Monte Carlo calculations were used to model the experiment. Good agreement was observed between the measured and calculated 238U fission contribution.


  • Open Access

    Measurement of Photoneutron Yields Using the RPI LINAC and Assessment of Evaluated Photoneutron Data for Tantalum and Beryllium

    by B. Epping, Michael Rapp, D. P. Barry, A. Daskalakis, Yaron Danon, Ezekiel Blain, Peter Brand, Michael Bretti, Matthew H. Gray, Larry Krusieski, et al.

    A new experiment configuration was designed, developed, and implemented to measure photoneutron yields using the Rensselaer Polytechnic Institute (RPI) electron linear accelerator (LINAC) at the RPI Gaerttner LINAC Center. The experiment configuration includes a new target assembly that converts the LINAC electron beam into a high energy bremsstrahlung photon flux incident upon a sample material of interest. The photons excite nuclei in the sample of interest, which can subsequently emit neutrons (photoneutrons). The photoneutrons emitted in the direction of the detector system travel through a series of collimated vacuum pipes before reaching a pair of proton-recoil high-energy neutron detectors. The signals generated by the neutron detectors are processed using a digital data acquisition system and subsequently analyzed to determine the energy-dependent photoneutron yield from the sample of interest. The new experiment configuration was used to perform proof-of-concept experiments to measure the photoneutron yields from samples of tantalum and beryllium. The measured results were then compared against the results from Monte Carlo simulations of the detailed experiment configurations to perform preliminary assessments of evaluated photoneutron data libraries.