Michael Rapp
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Michael Rapp has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- A. Daskalakis
Naval Nuclear Laboratory, Niskayuna, NY (United States)
5 shared publications - Yaron Danon
Rensselaer Polytechnic Institute
5 shared publications - Robert C. Block
Rensselaer Polytechnic Institute, Gaerttner LINAC Center, Troy, New York 12180
3 shared publications - D. P. Barry
Naval Nuclear Laboratory, P.O. Box 1072, Schenectady, New York 12301-1072
2 shared publications Ezekiel Blain
Rensselaer Polytechnic Institute, Gaerttner LINAC Center, 110 8th Street, Troy, New York, 12180, USA
2 shared publications- Adam Ney
Rensselaer Polytechnic Institute, Troy, New York, 12180
1 shared publication
Latest Publications
- 16 July 2025
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 224
A quasi-differential measurement of neutron scattering from tantalum between 0.65 MeV and 20 MeV
- 16 July 2025
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 224
A quasi-differential measurement of neutron scattering from tantalum between 0.65 MeV and 20 MeV
- Open Access
- 10 October 2023
- Published by Office of Scientific and Technical Information (OSTI)
Quasi-Differential Neutron Scattering Measurements of 181Ta and Teflon from 1.5 to 20 MeV [Slides]
This presentation covers motivation for the Experiments Performed. Secondly, it touches on upgrades to the Experimental Apparatus for Measurements. Thirdly, it presents quasi-Differential Experimental Methodology a) Pulse Shape Discrimination b) Validation Measurement of Carbon. The presentation concludes with Preliminary Results and Future Studies.
- 10 October 2023
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessQuasi-Differential Neutron Scattering Measurements of 181Ta and Teflon from 1.5 to 20 MeV [Slides]
This presentation covers motivation for the Experiments Performed. Secondly, it touches on upgrades to the Experimental Apparatus for Measurements. Thirdly, it presents quasi-Differential Experimental Methodology a) Pulse Shape Discrimination b) Validation Measurement of Carbon. The presentation concludes with Preliminary Results and Future Studies.
- Open Access
- 26 May 2023
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 284, 01039
Neutron Capture and Transmission Measurements of 54Fe at the RPI LINAC
54Fe radiative capture cross section and transmission measurements were conducted at the Rensselaer Polytechnic Institute (RPI) Gaerttner Linear Accelerator (LINAC) Center using an enriched 54Fe sample in the keV energy region. 54Fe is a constituent of natural iron, which is present in a large variety of nuclear grade materials. Therefore, it is important to have an accurate understanding of the cross sections of 54Fe, which can be measured experimentally. In the time-of-flight measurements conducted at the LINAC, an array of four C6D6 detectors surrounded the sample and radiative capture data were collected using a digital data acquisition system. Additionally, a Li-glass detector was used to collect transmission data using an analog data acquisition system. The radiative capture yield of the 54Fe measurements were normalized to saturated resonances observed in Au and Ta to obtain an absolute capture yield. The preliminary capture yield and preliminary transmission obtained can be compared to evaluations and existing experimental data. Some disagreements were observed in prominent d-wave capture resonances observed in 54Fe in the low-keV neutron energy region. Both sets of experimental data along with pre-existing datasets will greatly enhance RPI’s ability to perform resonance evaluation for 54Fe up to roughly 1 MeV.
- 26 May 2023
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 284, 01039
Open AccessNeutron Capture and Transmission Measurements of 54Fe at the RPI LINAC
54Fe radiative capture cross section and transmission measurements were conducted at the Rensselaer Polytechnic Institute (RPI) Gaerttner Linear Accelerator (LINAC) Center using an enriched 54Fe sample in the keV energy region. 54Fe is a constituent of natural iron, which is present in a large variety of nuclear grade materials. Therefore, it is important to have an accurate understanding of the cross sections of 54Fe, which can be measured experimentally. In the time-of-flight measurements conducted at the LINAC, an array of four C6D6 detectors surrounded the sample and radiative capture data were collected using a digital data acquisition system. Additionally, a Li-glass detector was used to collect transmission data using an analog data acquisition system. The radiative capture yield of the 54Fe measurements were normalized to saturated resonances observed in Au and Ta to obtain an absolute capture yield. The preliminary capture yield and preliminary transmission obtained can be compared to evaluations and existing experimental data. Some disagreements were observed in prominent d-wave capture resonances observed in 54Fe in the low-keV neutron energy region. Both sets of experimental data along with pre-existing datasets will greatly enhance RPI’s ability to perform resonance evaluation for 54Fe up to roughly 1 MeV.
- Open Access
- 26 May 2023
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 284, 01016
Method to Compare Fission-to-Scattering Ratios using Uranium-238
A novel method was developed to separate the 238U fission contribution measured in quasi-differential time-of-flight scattering experiments in order to isolate the elastic and inelastic events. Pulse height distributions from in-beam measurements were used to generate response functions, which were used to reconstruct the 238U prompt fission neutron spectra. This method was validated by reconstructing the measured 252Cf spontaneous fission pulse height distribution. Monte Carlo calculations were used to model the experiment. Good agreement was observed between the measured and calculated 238U fission contribution.
- 26 May 2023
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 284, 01016
Open AccessMethod to Compare Fission-to-Scattering Ratios using Uranium-238
A novel method was developed to separate the 238U fission contribution measured in quasi-differential time-of-flight scattering experiments in order to isolate the elastic and inelastic events. Pulse height distributions from in-beam measurements were used to generate response functions, which were used to reconstruct the 238U prompt fission neutron spectra. This method was validated by reconstructing the measured 252Cf spontaneous fission pulse height distribution. Monte Carlo calculations were used to model the experiment. Good agreement was observed between the measured and calculated 238U fission contribution.
- Open Access
- 26 May 2023
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 284, 01019
Measurement of Photoneutron Yields Using the RPI LINAC and Assessment of Evaluated Photoneutron Data for Tantalum and Beryllium
A new experiment configuration was designed, developed, and implemented to measure photoneutron yields using the Rensselaer Polytechnic Institute (RPI) electron linear accelerator (LINAC) at the RPI Gaerttner LINAC Center. The experiment configuration includes a new target assembly that converts the LINAC electron beam into a high energy bremsstrahlung photon flux incident upon a sample material of interest. The photons excite nuclei in the sample of interest, which can subsequently emit neutrons (photoneutrons). The photoneutrons emitted in the direction of the detector system travel through a series of collimated vacuum pipes before reaching a pair of proton-recoil high-energy neutron detectors. The signals generated by the neutron detectors are processed using a digital data acquisition system and subsequently analyzed to determine the energy-dependent photoneutron yield from the sample of interest. The new experiment configuration was used to perform proof-of-concept experiments to measure the photoneutron yields from samples of tantalum and beryllium. The measured results were then compared against the results from Monte Carlo simulations of the detailed experiment configurations to perform preliminary assessments of evaluated photoneutron data libraries.
- 26 May 2023
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 284, 01019
Open AccessMeasurement of Photoneutron Yields Using the RPI LINAC and Assessment of Evaluated Photoneutron Data for Tantalum and Beryllium
A new experiment configuration was designed, developed, and implemented to measure photoneutron yields using the Rensselaer Polytechnic Institute (RPI) electron linear accelerator (LINAC) at the RPI Gaerttner LINAC Center. The experiment configuration includes a new target assembly that converts the LINAC electron beam into a high energy bremsstrahlung photon flux incident upon a sample material of interest. The photons excite nuclei in the sample of interest, which can subsequently emit neutrons (photoneutrons). The photoneutrons emitted in the direction of the detector system travel through a series of collimated vacuum pipes before reaching a pair of proton-recoil high-energy neutron detectors. The signals generated by the neutron detectors are processed using a digital data acquisition system and subsequently analyzed to determine the energy-dependent photoneutron yield from the sample of interest. The new experiment configuration was used to perform proof-of-concept experiments to measure the photoneutron yields from samples of tantalum and beryllium. The measured results were then compared against the results from Monte Carlo simulations of the detailed experiment configurations to perform preliminary assessments of evaluated photoneutron data libraries.