A. Daskalakis
A. Daskalakis has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Yaron Danon
Rensselaer Polytechnic Institute
8 shared publications - Michael Rapp
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
5 shared publications - Robert C. Block
Rensselaer Polytechnic Institute, Gaerttner LINAC Center, Troy, New York 12180
5 shared publications - D. P. Barry
Naval Nuclear Laboratory, P.O. Box 1072, Schenectady, New York 12301-1072
3 shared publications Ezekiel Blain
Rensselaer Polytechnic Institute, Gaerttner LINAC Center, 110 8th Street, Troy, New York, 12180, USA
2 shared publicationsPeter Brain
Rensselaer Polytechnic Institute, Troy, NY (United States)
2 shared publications
Latest Publications
- 16 July 2025
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 224
A quasi-differential measurement of neutron scattering from tantalum between 0.65 MeV and 20 MeV
- 16 July 2025
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 224
A quasi-differential measurement of neutron scattering from tantalum between 0.65 MeV and 20 MeV
- Open Access
- 12 October 2023
- Published by Office of Scientific and Technical Information (OSTI)
Deployment of Gaussian Surrogate Model for Ad-Hoc Adjustments to Elastic Scattering Angular Distributions [Slides]
This presentation is on the deployment of gaussian surrogate model for ad-hoc adjustments to elastic scattering angular distributions. Discussed throughout the presentation is motivation for this lecture. Specifically, the gaussian surrogate models, validation of method with Pb-208, and the application on Be-9 are highlighted. The presentation concludes with a summary.
- 12 October 2023
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessDeployment of Gaussian Surrogate Model for Ad-Hoc Adjustments to Elastic Scattering Angular Distributions [Slides]
This presentation is on the deployment of gaussian surrogate model for ad-hoc adjustments to elastic scattering angular distributions. Discussed throughout the presentation is motivation for this lecture. Specifically, the gaussian surrogate models, validation of method with Pb-208, and the application on Be-9 are highlighted. The presentation concludes with a summary.
- Open Access
- 10 October 2023
- Published by Office of Scientific and Technical Information (OSTI)
Quasi-Differential Neutron Scattering Measurements of 181Ta and Teflon from 1.5 to 20 MeV [Slides]
This presentation covers motivation for the Experiments Performed. Secondly, it touches on upgrades to the Experimental Apparatus for Measurements. Thirdly, it presents quasi-Differential Experimental Methodology a) Pulse Shape Discrimination b) Validation Measurement of Carbon. The presentation concludes with Preliminary Results and Future Studies.
- 10 October 2023
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessQuasi-Differential Neutron Scattering Measurements of 181Ta and Teflon from 1.5 to 20 MeV [Slides]
This presentation covers motivation for the Experiments Performed. Secondly, it touches on upgrades to the Experimental Apparatus for Measurements. Thirdly, it presents quasi-Differential Experimental Methodology a) Pulse Shape Discrimination b) Validation Measurement of Carbon. The presentation concludes with Preliminary Results and Future Studies.
- Open Access
- 26 May 2023
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 284, 01039
Neutron Capture and Transmission Measurements of 54Fe at the RPI LINAC
54Fe radiative capture cross section and transmission measurements were conducted at the Rensselaer Polytechnic Institute (RPI) Gaerttner Linear Accelerator (LINAC) Center using an enriched 54Fe sample in the keV energy region. 54Fe is a constituent of natural iron, which is present in a large variety of nuclear grade materials. Therefore, it is important to have an accurate understanding of the cross sections of 54Fe, which can be measured experimentally. In the time-of-flight measurements conducted at the LINAC, an array of four C6D6 detectors surrounded the sample and radiative capture data were collected using a digital data acquisition system. Additionally, a Li-glass detector was used to collect transmission data using an analog data acquisition system. The radiative capture yield of the 54Fe measurements were normalized to saturated resonances observed in Au and Ta to obtain an absolute capture yield. The preliminary capture yield and preliminary transmission obtained can be compared to evaluations and existing experimental data. Some disagreements were observed in prominent d-wave capture resonances observed in 54Fe in the low-keV neutron energy region. Both sets of experimental data along with pre-existing datasets will greatly enhance RPI’s ability to perform resonance evaluation for 54Fe up to roughly 1 MeV.
- 26 May 2023
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 284, 01039
Open AccessNeutron Capture and Transmission Measurements of 54Fe at the RPI LINAC
54Fe radiative capture cross section and transmission measurements were conducted at the Rensselaer Polytechnic Institute (RPI) Gaerttner Linear Accelerator (LINAC) Center using an enriched 54Fe sample in the keV energy region. 54Fe is a constituent of natural iron, which is present in a large variety of nuclear grade materials. Therefore, it is important to have an accurate understanding of the cross sections of 54Fe, which can be measured experimentally. In the time-of-flight measurements conducted at the LINAC, an array of four C6D6 detectors surrounded the sample and radiative capture data were collected using a digital data acquisition system. Additionally, a Li-glass detector was used to collect transmission data using an analog data acquisition system. The radiative capture yield of the 54Fe measurements were normalized to saturated resonances observed in Au and Ta to obtain an absolute capture yield. The preliminary capture yield and preliminary transmission obtained can be compared to evaluations and existing experimental data. Some disagreements were observed in prominent d-wave capture resonances observed in 54Fe in the low-keV neutron energy region. Both sets of experimental data along with pre-existing datasets will greatly enhance RPI’s ability to perform resonance evaluation for 54Fe up to roughly 1 MeV.
- Open Access
- 26 May 2023
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 284, 01016
Method to Compare Fission-to-Scattering Ratios using Uranium-238
A novel method was developed to separate the 238U fission contribution measured in quasi-differential time-of-flight scattering experiments in order to isolate the elastic and inelastic events. Pulse height distributions from in-beam measurements were used to generate response functions, which were used to reconstruct the 238U prompt fission neutron spectra. This method was validated by reconstructing the measured 252Cf spontaneous fission pulse height distribution. Monte Carlo calculations were used to model the experiment. Good agreement was observed between the measured and calculated 238U fission contribution.
- 26 May 2023
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 284, 01016
Open AccessMethod to Compare Fission-to-Scattering Ratios using Uranium-238
A novel method was developed to separate the 238U fission contribution measured in quasi-differential time-of-flight scattering experiments in order to isolate the elastic and inelastic events. Pulse height distributions from in-beam measurements were used to generate response functions, which were used to reconstruct the 238U prompt fission neutron spectra. This method was validated by reconstructing the measured 252Cf spontaneous fission pulse height distribution. Monte Carlo calculations were used to model the experiment. Good agreement was observed between the measured and calculated 238U fission contribution.
- Open Access
- 26 May 2023
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 284, 01019
Measurement of Photoneutron Yields Using the RPI LINAC and Assessment of Evaluated Photoneutron Data for Tantalum and Beryllium
A new experiment configuration was designed, developed, and implemented to measure photoneutron yields using the Rensselaer Polytechnic Institute (RPI) electron linear accelerator (LINAC) at the RPI Gaerttner LINAC Center. The experiment configuration includes a new target assembly that converts the LINAC electron beam into a high energy bremsstrahlung photon flux incident upon a sample material of interest. The photons excite nuclei in the sample of interest, which can subsequently emit neutrons (photoneutrons). The photoneutrons emitted in the direction of the detector system travel through a series of collimated vacuum pipes before reaching a pair of proton-recoil high-energy neutron detectors. The signals generated by the neutron detectors are processed using a digital data acquisition system and subsequently analyzed to determine the energy-dependent photoneutron yield from the sample of interest. The new experiment configuration was used to perform proof-of-concept experiments to measure the photoneutron yields from samples of tantalum and beryllium. The measured results were then compared against the results from Monte Carlo simulations of the detailed experiment configurations to perform preliminary assessments of evaluated photoneutron data libraries.
- 26 May 2023
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 284, 01019
Open AccessMeasurement of Photoneutron Yields Using the RPI LINAC and Assessment of Evaluated Photoneutron Data for Tantalum and Beryllium
A new experiment configuration was designed, developed, and implemented to measure photoneutron yields using the Rensselaer Polytechnic Institute (RPI) electron linear accelerator (LINAC) at the RPI Gaerttner LINAC Center. The experiment configuration includes a new target assembly that converts the LINAC electron beam into a high energy bremsstrahlung photon flux incident upon a sample material of interest. The photons excite nuclei in the sample of interest, which can subsequently emit neutrons (photoneutrons). The photoneutrons emitted in the direction of the detector system travel through a series of collimated vacuum pipes before reaching a pair of proton-recoil high-energy neutron detectors. The signals generated by the neutron detectors are processed using a digital data acquisition system and subsequently analyzed to determine the energy-dependent photoneutron yield from the sample of interest. The new experiment configuration was used to perform proof-of-concept experiments to measure the photoneutron yields from samples of tantalum and beryllium. The measured results were then compared against the results from Monte Carlo simulations of the detailed experiment configurations to perform preliminary assessments of evaluated photoneutron data libraries.
- Open Access
- 13 July 2017
- Published by American Physical Society (APS) in Physical Review C
- Vol. 96 (1) , 014607
() cross section and average resonance parameter measurements in the unresolved resonance region from 24 to 1180 keV using a filtered-beam techniqueA new array of four Deuterated Benzene () detectors has been installed at the Gaerttner Linear Accelerator Center at Rensselaer Polytechnic Institute for the purpose of measuring neutron capture cross sections in the keV region. Measurements were performed on samples of in the unresolved resonance region (URR) using a filtered-beam technique, by which a 30 cm iron filter was placed in a white-spectrum neutron beam to remove all time-dependent -ray background and all neutrons except those transmitted through resonance-potential interference “windows” in the iron. The resulting filtered beam was effectively a quasimonoenergetic neutron source, which was used for performing measurements on isotopes with narrow level spacings in the URR. The capture cross-section results obtained for two thicknesses of tantalum are in agreement with those documented in the JEFF-3.2 library, as are the average resonance parameters obtained via a fit to the data using the sammy-fitacs code.- 13 July 2017
- Published by American Physical Society (APS) in Physical Review C
- Vol. 96 (1) , 014607
Open Access() cross section and average resonance parameter measurements in the unresolved resonance region from 24 to 1180 keV using a filtered-beam techniqueA new array of four Deuterated Benzene () detectors has been installed at the Gaerttner Linear Accelerator Center at Rensselaer Polytechnic Institute for the purpose of measuring neutron capture cross sections in the keV region. Measurements were performed on samples of in the unresolved resonance region (URR) using a filtered-beam technique, by which a 30 cm iron filter was placed in a white-spectrum neutron beam to remove all time-dependent -ray background and all neutrons except those transmitted through resonance-potential interference “windows” in the iron. The resulting filtered beam was effectively a quasimonoenergetic neutron source, which was used for performing measurements on isotopes with narrow level spacings in the URR. The capture cross-section results obtained for two thicknesses of tantalum are in agreement with those documented in the JEFF-3.2 library, as are the average resonance parameters obtained via a fit to the data using the sammy-fitacs code. - Open Access
- 30 June 2017
- Published by American Physical Society (APS) in Physical Review C
- Vol. 95 (6) , 064615
Measurement of prompt fission neutron spectrum for spontaneous fission of using multiplicity taggingThe prompt fission neutron spectrum from spontaneous fission of is an integral part of several aspects of nuclear data. Not only is the spectrum itself of interest, but neutron detectors often use the spectrum for calibration, and other prompt fission neutron spectra are measured as a ratio to . Therefore, reducing the uncertainties in this spectrum will allow for more accurate nuclear data to be available across a wide range of fields. The prompt fission neutron spectrum for the spontaneous fission of was measured at Rensselaer Polytechnic Institute using the multiple tagging method with a 18.4-ng fission sample. An EJ-301 liquid scintillator fast neutron detector was used to measure the high energy portion of the spectrum, 0.5–7 MeV, and a thin EJ-204 plastic scintillator was used to measure the low energy portion of the spectrum, from 50 keV to 2 MeV. These spectra both show good agreement with the current evaluation of and have low associated uncertainties providing a new high precision measurement that helps reduce the uncertainties in the prompt fission neutron spectrum for the spontaneous fission of .- 30 June 2017
- Published by American Physical Society (APS) in Physical Review C
- Vol. 95 (6) , 064615
Open AccessMeasurement of prompt fission neutron spectrum for spontaneous fission of using multiplicity taggingThe prompt fission neutron spectrum from spontaneous fission of is an integral part of several aspects of nuclear data. Not only is the spectrum itself of interest, but neutron detectors often use the spectrum for calibration, and other prompt fission neutron spectra are measured as a ratio to . Therefore, reducing the uncertainties in this spectrum will allow for more accurate nuclear data to be available across a wide range of fields. The prompt fission neutron spectrum for the spontaneous fission of was measured at Rensselaer Polytechnic Institute using the multiple tagging method with a 18.4-ng fission sample. An EJ-301 liquid scintillator fast neutron detector was used to measure the high energy portion of the spectrum, 0.5–7 MeV, and a thin EJ-204 plastic scintillator was used to measure the low energy portion of the spectrum, from 50 keV to 2 MeV. These spectra both show good agreement with the current evaluation of and have low associated uncertainties providing a new high precision measurement that helps reduce the uncertainties in the prompt fission neutron spectrum for the spontaneous fission of .