  • Medical staff monitoring in interventional cardiology: over apron dosemeter placement based on measurements and simulations

    by Paolo Ferrari, Giovanna Venturi, Lorenzo Campani, Francesca Mariotti, Frank Becker, Jan Jansen, Zoran Jovanović, Dragana Krstić, Pedro Teles

    Interventional cardiology is characterized by high radiation exposure for both the patient and the operator. Adequate shielding and monitoring of the operator are fundamental to comply with radiation protection principles. In a previous work, the effect on the dose of the dosemeter position on the chest was studied. In this paper, the investigation has been completed, employing an anthropomorphic thorax phantom, equipped with arms. Although there are differences between the Monte Carlo simulations and the measurements, similar trends are observed, showing that the reduction in dose, due to the arms, is between 20 and 60%, compared with the situation without arms. For that reason, considering a dosemeter placed on the chest, the upper position, which is the least affected by the arms, should be preferred while the extreme lateral position, near the armpit, should be avoided.


  • ENEA extremity dosemeter based on LiF(Mg,Cu,P) to evaluate Hp(3, )

    by F. Mariotti, E. Fantuzzi, B. Morelli, G. Gualdrini, M. C. Botta, G. Uleri, J. M. Bordy, M. Denoziere

    Recent epidemiological studies suggest a rather low-dose threshold (Hp(d), in §(136), reads that ‘… a depth d=3 mm has been proposed for the rare case of monitoring the dose to the lens of the eye. In practice, however, Hp(3) has rarely been monitored and Hp(0.07) can be used for the same monitoring purpose… ’. As recommended on the EU ‘Technical recommendations for monitoring individuals occupationally exposed to external radiation’, a test on the ENEA TL extremity dosemeter is herein reported. The results within the actual EU founded Optimization of RAdiation protection for MEDical staff (ORAMED) Project, whose WP2 is aimed at the quantity Hp(3) and eye lens dosimetry in practice, are taken into account. The paper summarises the main aspects of the study carried out at ENEA-Radiation Protection Institute (Bologna, Italy) to provide practical solutions (in the use and the design) to evaluate the response of the ENEA TL extremity dosemeter in terms of Hp(3).