Muhittin Toman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Muhittin Toman has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Suna Toksavul
Department of Prosthetic Dentistry, Faculty of Dentistry, Ege University, Bornova-Izmir, Turkey
9 shared publications - Ibrahim Nergiz
Associate Professor, Department of Restorative and Preventive Dentistry, School of Dental and Oral Medicine, University of Hamburg, Hamburg, Germany
3 shared publications - Petra Schmage
Department of Restorative and Preventive Dentistry, School of Dental and Oral Medicine, University of Hamburg, Hamburg, Germany
3 shared publications Aslı Akın
Department of Prosthetic Dentistry, Faculty of Dentistry, Ege University, İzmir, Turkey
2 shared publicationsEbru Cal
2 shared publicationsMehmet Sarikanat
2 shared publications
Latest Publications
- 1 January 2016
- Vol. 47 (6) , 461-471
3D quantification of clinical marginal and internal gap of porcelain laminate veneers with minimal and without tooth preparation and 2-year clinical evaluation
In this in-vivo study, mean and median values of marginal gap and internal adaptation for PLV with minimal tooth preparation and PLVs without tooth preparation were within a clinically acceptable range. A 100% success rate was recorded for all PLV during the 2-year period.
- 1 January 2016
- Vol. 47 (6) , 461-471
3D quantification of clinical marginal and internal gap of porcelain laminate veneers with minimal and without tooth preparation and 2-year clinical evaluation
In this in-vivo study, mean and median values of marginal gap and internal adaptation for PLV with minimal tooth preparation and PLVs without tooth preparation were within a clinically acceptable range. A 100% success rate was recorded for all PLV during the 2-year period.
- 1 October 2014
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 112 (4) , 909-913
Clinical marginal and internal adaptation of CAD/CAM milling, laser sintering, and cast metal ceramic crowns
- 1 October 2014
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 112 (4) , 909-913
Clinical marginal and internal adaptation of CAD/CAM milling, laser sintering, and cast metal ceramic crowns
- 14 September 2014
- Published by Wiley in Journal of Prosthodontics
- Vol. 24 (5) , 345-350
Clinical Marginal and Internal Adaptation of Maxillary Anterior Single All‐Ceramic Crowns and 2‐year Randomized Controlled Clinical Trial
Purpose: The aims of this randomized‐controlled clinical trial were to compare marginal and internal adaptation of all‐ceramic crowns fabricated with CAD/CAM and heat‐pressed (HP) techniques before luting and to evaluate the clinical outcomes at baseline and at 6, 12, and 24 months after luting.Materials and Methods: Fifteen CAD/CAM (CC) and 15 HP all‐ceramic crowns were placed in 15 patients. A silicone replica was obtained to measure marginal and internal adaptation of each all‐ceramic crown before luting, and they were sectioned buccolingually and mesiodistally. Marginal and internal adaptations were measured using computerized light microscope at 40× magnification. Clinical evaluations took place at baseline (2 days after luting) and at 6, 12, and 24 months after luting. Replica scores were analyzed with Mann‐Whitney U and Student's t‐test (α = 0.05). Survival rate of crowns was determined using Kaplan‐Meier statistical analysis.Results: The median marginal gap for the CC group was 132.2 μm and was 130.2 μm for the HP group. The mean internal adaptation for the CC group was 220.3 ± 51.3 μm and 210.5 ± 31 μm for the HP group. There were no statistically significant differences with respect to marginal opening (Mann‐Whitney U test; p = 0.95) and internal adaptation (Student's t‐test; p = 0.535) between the 2 groups. Based on modified Ryge criteria, 100% of the crowns were rated satisfactory during the 2‐year period.Conclusion: In this in vivo study, CAD/CAM and HP all‐ceramic crowns exhibited similar marginal and internal adaptations. A 100% success rate was recorded for the 15 CAD/CAM and for the 15 HP all‐ceramic crowns during the 2‐year period.
- 14 September 2014
- Published by Wiley in Journal of Prosthodontics
- Vol. 24 (5) , 345-350
Clinical Marginal and Internal Adaptation of Maxillary Anterior Single All‐Ceramic Crowns and 2‐year Randomized Controlled Clinical Trial
Purpose: The aims of this randomized‐controlled clinical trial were to compare marginal and internal adaptation of all‐ceramic crowns fabricated with CAD/CAM and heat‐pressed (HP) techniques before luting and to evaluate the clinical outcomes at baseline and at 6, 12, and 24 months after luting.Materials and Methods: Fifteen CAD/CAM (CC) and 15 HP all‐ceramic crowns were placed in 15 patients. A silicone replica was obtained to measure marginal and internal adaptation of each all‐ceramic crown before luting, and they were sectioned buccolingually and mesiodistally. Marginal and internal adaptations were measured using computerized light microscope at 40× magnification. Clinical evaluations took place at baseline (2 days after luting) and at 6, 12, and 24 months after luting. Replica scores were analyzed with Mann‐Whitney U and Student's t‐test (α = 0.05). Survival rate of crowns was determined using Kaplan‐Meier statistical analysis.Results: The median marginal gap for the CC group was 132.2 μm and was 130.2 μm for the HP group. The mean internal adaptation for the CC group was 220.3 ± 51.3 μm and 210.5 ± 31 μm for the HP group. There were no statistically significant differences with respect to marginal opening (Mann‐Whitney U test; p = 0.95) and internal adaptation (Student's t‐test; p = 0.535) between the 2 groups. Based on modified Ryge criteria, 100% of the crowns were rated satisfactory during the 2‐year period.Conclusion: In this in vivo study, CAD/CAM and HP all‐ceramic crowns exhibited similar marginal and internal adaptations. A 100% success rate was recorded for the 15 CAD/CAM and for the 15 HP all‐ceramic crowns during the 2‐year period.
- 1 January 2014
- Published by LookUs Bilisim A.S. in Journal of Ege University School of Dentistry
- Vol. 35 (3) , 33-40
Effect of surface conditioning on bond strength between zirconia ceramic and composite resin luting agent
- 1 January 2014
- Published by LookUs Bilisim A.S. in Journal of Ege University School of Dentistry
- Vol. 35 (3) , 33-40
Effect of surface conditioning on bond strength between zirconia ceramic and composite resin luting agent
- 1 March 2012
- Vol. 25 (2) , 135-7
Masticatory performance and mandibular movement patterns of patients with natural dentitions, complete dentures, and implant-supported overdentures.
The aim of this study was to compare quantitatively the masticatory performance of patients with overdentures supported by two implants, conventional complete dentures, and natural dentitions. Each patient was asked to chew a gelatin cube. The collected remains of the test food (gelatine cube) were fractioned by a sieving procedure and weighed. Maximum mouth opening and masticatory area were measured using kinesiography. There were statistically significant differences among groups with respect to masticatory performance using a 3.15-mm-diameter sieve (P < .001) and 0.5-mm-diameter sieve (P < .001), masticatory area (P = .019), and maximum mouth opening (P < .001). Increasing retention of a mandibular complete denture with two implants improved masticatory performance.
- 1 March 2012
- Vol. 25 (2) , 135-7
Masticatory performance and mandibular movement patterns of patients with natural dentitions, complete dentures, and implant-supported overdentures.
The aim of this study was to compare quantitatively the masticatory performance of patients with overdentures supported by two implants, conventional complete dentures, and natural dentitions. Each patient was asked to chew a gelatin cube. The collected remains of the test food (gelatine cube) were fractioned by a sieving procedure and weighed. Maximum mouth opening and masticatory area were measured using kinesiography. There were statistically significant differences among groups with respect to masticatory performance using a 3.15-mm-diameter sieve (P < .001) and 0.5-mm-diameter sieve (P < .001), masticatory area (P = .019), and maximum mouth opening (P < .001). Increasing retention of a mandibular complete denture with two implants improved masticatory performance.
- 1 March 2010
- Vol. 18 (1) , 2-7
Effect of noble metal alloy post and core material on the fracture resistance of endodontically treated teeth.
The aim of this study was to investigate the effect of one particular brand of post and core system (ER Post) consisted of different post and core materials on the fracture resistance of endodontically treated teeth. Fifty caries-free maxillary central incisors were randomly assigned to five groups (n=10). All teeth were sectioned at the cemento-enamel junction except for the teeth in the control group. Four experimental groups consisted of cast gold post-and-core group (GG), Heraplat post/cast gold core group (HG), titanium post/composite core (TC), and titanium post/cast gold core (TG). The control group (ETT) consisted of endodontically treated teeth without posts. All posts were cemented in the roots with zinc phosphate cement. Following thermal cycling (5000 cycles between 5 degrees C and 55 degrees C with a dwell time of 30 seconds) a static load was applied to 2 mm below the incisal edge on the palatal surface of each specimen until they were fractured. Fracture data obtained and statistically analyzed with one-way ANOVA and a Tukey's test (p<0.05). Means of the fracture resistance during static loading were: 423.76 N (GG), 529.46 N (HG), 389.08 N (TC), 408.7 N (TG), 404.4 N (ETT, control). Heraplat post with cast gold core exhibited the highest fracture load than the other groups (p<0.05). Specimens in groups HG and ETT (control) showed the most repairable failure. Heraplat post with cast gold core had the highest fracture resistance of endodontically treated teeth.
- 1 March 2010
- Vol. 18 (1) , 2-7
Effect of noble metal alloy post and core material on the fracture resistance of endodontically treated teeth.
The aim of this study was to investigate the effect of one particular brand of post and core system (ER Post) consisted of different post and core materials on the fracture resistance of endodontically treated teeth. Fifty caries-free maxillary central incisors were randomly assigned to five groups (n=10). All teeth were sectioned at the cemento-enamel junction except for the teeth in the control group. Four experimental groups consisted of cast gold post-and-core group (GG), Heraplat post/cast gold core group (HG), titanium post/composite core (TC), and titanium post/cast gold core (TG). The control group (ETT) consisted of endodontically treated teeth without posts. All posts were cemented in the roots with zinc phosphate cement. Following thermal cycling (5000 cycles between 5 degrees C and 55 degrees C with a dwell time of 30 seconds) a static load was applied to 2 mm below the incisal edge on the palatal surface of each specimen until they were fractured. Fracture data obtained and statistically analyzed with one-way ANOVA and a Tukey's test (p<0.05). Means of the fracture resistance during static loading were: 423.76 N (GG), 529.46 N (HG), 389.08 N (TC), 408.7 N (TG), 404.4 N (ETT, control). Heraplat post with cast gold core exhibited the highest fracture load than the other groups (p<0.05). Specimens in groups HG and ETT (control) showed the most repairable failure. Heraplat post with cast gold core had the highest fracture resistance of endodontically treated teeth.
- 1 March 2010
- Vol. 18 (1) , 23-30
Fracture resistance of endodontically treated teeth: effect of tooth coloured post material and surface conditioning.
This in vitro study evaluated the effects of the different endodontic posts and surface conditioning on the fracture resistance and fracture modes of endodontically treated teeth. The experimental groups consisted of zirconia ceramic post with a glasss-ceramic core [A], zirconia ceramic post with a composite core [B], glass fiber composite post (FRC) with a composite core [C], and titanium post with a composite core [D]. All posts in these groups were cemented with self-adhesive resin cement (Rely X Unicem Aplicap) combination with tribochemical silica coating (TSC). Groups E, F, G and H comprised the same post-and-core materials as the first 4 groups but cemented with the same resin cement without TSC. Specimens were subjected to thermal cycling between 5 degrees C and 55 degrees C for a total of 5000 cycles with 30s per cycle. Static load was applied to the palatal surface of each specimen until they were fractured. Statistical analysis was conducted using analysis of variance (ANOVA) followed by post-hoc comparisons (Tukey). The fracture resistance was significantly affected by the post material (P < 0.001) and surface conditioning (P < 0.001; two-way ANOVA). The application of TSC to post surface decreased the fracture resistance of zirconia ceramic post with composite core (p=0.002; Tukey) and glass FRC post with composite core (p=0.029; Tukey). No catastrophic failure was observed for groups B, C, D, E, F and G. Under the testing conditions used, the titanium post/composite core that had been silicoated exhibited the highest fracture resistance.
- 1 March 2010
- Vol. 18 (1) , 23-30
Fracture resistance of endodontically treated teeth: effect of tooth coloured post material and surface conditioning.
This in vitro study evaluated the effects of the different endodontic posts and surface conditioning on the fracture resistance and fracture modes of endodontically treated teeth. The experimental groups consisted of zirconia ceramic post with a glasss-ceramic core [A], zirconia ceramic post with a composite core [B], glass fiber composite post (FRC) with a composite core [C], and titanium post with a composite core [D]. All posts in these groups were cemented with self-adhesive resin cement (Rely X Unicem Aplicap) combination with tribochemical silica coating (TSC). Groups E, F, G and H comprised the same post-and-core materials as the first 4 groups but cemented with the same resin cement without TSC. Specimens were subjected to thermal cycling between 5 degrees C and 55 degrees C for a total of 5000 cycles with 30s per cycle. Static load was applied to the palatal surface of each specimen until they were fractured. Statistical analysis was conducted using analysis of variance (ANOVA) followed by post-hoc comparisons (Tukey). The fracture resistance was significantly affected by the post material (P < 0.001) and surface conditioning (P < 0.001; two-way ANOVA). The application of TSC to post surface decreased the fracture resistance of zirconia ceramic post with composite core (p=0.002; Tukey) and glass FRC post with composite core (p=0.029; Tukey). No catastrophic failure was observed for groups B, C, D, E, F and G. Under the testing conditions used, the titanium post/composite core that had been silicoated exhibited the highest fracture resistance.
- 6 August 2009
- Published by Wiley in International Endodontic Journal
- Vol. 42 (9) , 802-810
The evaluation of displacement resistance of glass FRC posts to root dentine using a thin slice push‐out test
Aim To investigate and compare the displacement resistance of glass fibre reinforced composite (FRC) posts to root dentine after luting with different adhesive systems.Methodology A total of 32 noncarious extracted human mandibular premolars were prepared for post‐cementation using the FRC Postec system (Ivoclar Vivadent, Schaan, Liechtenstein) and divided into four groups (n = 8). The posts in each group were luted with one or other of the following materials. Group 1: Variolink II/Excite DSC (etch‐and‐rinse, dual‐curing), group 2: Clearfil Esthetic Cement/ED Primer II (self‐etch, dual‐curing), group 3: Multilink/Multilink Primer (self‐etch, chemical‐curing) and group 4: Multilink Sprint (self‐adhesive, dual‐curing). Specimens were sectioned to obtain slices with the post in the centre and with the root dentine overlaid by the autopolymerizing acrylic resin on each side. The displacement resistance was measured using a Universal Testing Machine at a crosshead speed of 0.5 mm min−1. The displacement resistance of the specimens were calculated and expressed in MPa. Data were analysed with one‐way anova and post hoc Tukey’s test (P < 0.05).Results Mean (SD) values of displacement resistance data in MPa are as follows: group 1, 12.08 (2.13); group 2, 12.39 (2); group 3, 11.3 (1.23); group 4, 14.29 (1.84). There were statistically significant differences amongst the groups (P = 0.021). A statistically significant difference was observed for the displacement resistance values between groups 3 and 4 (P = 0.015), that is between Multilink/Multilink Primer and Multilink Sprint.Conclusions Glass FRC posts luted with self‐adhesive luting system exhibited higher displacement resistance than when luted with chemical‐curing self‐etch luting system.
- 6 August 2009
- Published by Wiley in International Endodontic Journal
- Vol. 42 (9) , 802-810
The evaluation of displacement resistance of glass FRC posts to root dentine using a thin slice push‐out test
Aim To investigate and compare the displacement resistance of glass fibre reinforced composite (FRC) posts to root dentine after luting with different adhesive systems.Methodology A total of 32 noncarious extracted human mandibular premolars were prepared for post‐cementation using the FRC Postec system (Ivoclar Vivadent, Schaan, Liechtenstein) and divided into four groups (n = 8). The posts in each group were luted with one or other of the following materials. Group 1: Variolink II/Excite DSC (etch‐and‐rinse, dual‐curing), group 2: Clearfil Esthetic Cement/ED Primer II (self‐etch, dual‐curing), group 3: Multilink/Multilink Primer (self‐etch, chemical‐curing) and group 4: Multilink Sprint (self‐adhesive, dual‐curing). Specimens were sectioned to obtain slices with the post in the centre and with the root dentine overlaid by the autopolymerizing acrylic resin on each side. The displacement resistance was measured using a Universal Testing Machine at a crosshead speed of 0.5 mm min−1. The displacement resistance of the specimens were calculated and expressed in MPa. Data were analysed with one‐way anova and post hoc Tukey’s test (P < 0.05).Results Mean (SD) values of displacement resistance data in MPa are as follows: group 1, 12.08 (2.13); group 2, 12.39 (2); group 3, 11.3 (1.23); group 4, 14.29 (1.84). There were statistically significant differences amongst the groups (P = 0.021). A statistically significant difference was observed for the displacement resistance values between groups 3 and 4 (P = 0.015), that is between Multilink/Multilink Primer and Multilink Sprint.Conclusions Glass FRC posts luted with self‐adhesive luting system exhibited higher displacement resistance than when luted with chemical‐curing self‐etch luting system.
- 1 August 2009
- Vol. 11 (4) , 299-303
Bond strength of different dentin bonding systems to fluorotic enamel.
The effect of three different bonding strategies on the shear bond strength of a resin composite to fluorotic enamel surfaces was investigated. Thirty-six noncarious extracted human molars with fluorosis and 36 without fluorosis were scraped clean from any remaining tissue, and then were divided into three subgroups according to the tested dentin bonding systems. The resin composite was bonded to the teeth using three different adhesive systems: Peak LC Bond with an etch-and-rinse technique (Ultradent Products), Peak LC Bond with a self-etching technique using Peak SE Primer (Ultradent Products), and Xeno V (Dentsply Caulk) using a one-bottle self-etching technique. Following the photopolymerization of the resin composites, thermocycling was performed 5000 times. Shear bond strengths were tested using the Shimadzu Universal Testing Machine until failure. The analysis of the fractured enamel surfaces was performed using an optical microscope (Nikon ECLIPSE ME 600) at 10X and 1000X magnification, and the images were analyzed with an image analyzer (LUCIA 4.21). The data obtained were analyzed with two-way ANOVA and the Bonferroni test at a significance level of p < 0.05. Mean shear bond strengths in MPa of the groups were: Peak LC Bond, self-etching, on fluorotic enamel 13.23 +/- 2.58 and on nonfluorotic enamel 17.81 +/- 2.90; Peak LC Bond, etch-and-rinse, on fluorotic enamel 16.77 +/- 2.32 and on nonfluorotic enamel 21.13 +/- 2.74; one-bottle self-etching Xeno V on fluorotic enamel 10.79 +/- 2.14 and on nonfluorotic enamel 14.58 +/- 2.99. Fluorosis adversely affected the bonding performance of all the bonding systems to enamel. The use of the etch-and-rinse dentin bonding technique produced higher bond strengths of the resin composite tested to fluorotic and nonfluorotic enamel compared to both self-etching techniques.
- 1 August 2009
- Vol. 11 (4) , 299-303
Bond strength of different dentin bonding systems to fluorotic enamel.
The effect of three different bonding strategies on the shear bond strength of a resin composite to fluorotic enamel surfaces was investigated. Thirty-six noncarious extracted human molars with fluorosis and 36 without fluorosis were scraped clean from any remaining tissue, and then were divided into three subgroups according to the tested dentin bonding systems. The resin composite was bonded to the teeth using three different adhesive systems: Peak LC Bond with an etch-and-rinse technique (Ultradent Products), Peak LC Bond with a self-etching technique using Peak SE Primer (Ultradent Products), and Xeno V (Dentsply Caulk) using a one-bottle self-etching technique. Following the photopolymerization of the resin composites, thermocycling was performed 5000 times. Shear bond strengths were tested using the Shimadzu Universal Testing Machine until failure. The analysis of the fractured enamel surfaces was performed using an optical microscope (Nikon ECLIPSE ME 600) at 10X and 1000X magnification, and the images were analyzed with an image analyzer (LUCIA 4.21). The data obtained were analyzed with two-way ANOVA and the Bonferroni test at a significance level of p < 0.05. Mean shear bond strengths in MPa of the groups were: Peak LC Bond, self-etching, on fluorotic enamel 13.23 +/- 2.58 and on nonfluorotic enamel 17.81 +/- 2.90; Peak LC Bond, etch-and-rinse, on fluorotic enamel 16.77 +/- 2.32 and on nonfluorotic enamel 21.13 +/- 2.74; one-bottle self-etching Xeno V on fluorotic enamel 10.79 +/- 2.14 and on nonfluorotic enamel 14.58 +/- 2.99. Fluorosis adversely affected the bonding performance of all the bonding systems to enamel. The use of the etch-and-rinse dentin bonding technique produced higher bond strengths of the resin composite tested to fluorotic and nonfluorotic enamel compared to both self-etching techniques.
- 1 October 2008
- Vol. 10 (5) , 373-8
Bond strength of all-ceramics to tooth structure: using new luting systems.
To examine the effect of different adhesive luting systems on the shear bond strength of all-ceramic restorations to dentin surfaces. Forty-eight all-ceramic disks (2 x 3 mm; IPS e.max Press) were fabricated. Forty-eight noncarious extracted human molars were divided into 4 groups. in groups 1 to 4, IPS e.max Press disks were luted with Variolink 2/Excite DSC (etch-and-rinse), Clearfil Esthetic Cement/Clearfil Protect Bond (antibacterial and self-etching), Multilink/Multilink Primer (self-etching), or Multilink Sprint (self-adhesive). All specimens were subjected to 5000 thermocycles (5 degrees C to 55 degrees C, 30-s dwell time). Shear bond strengths were tested using a universal testing machine until failure. The analysis of the fractured dentin surfaces was performed using an optical microscope at 10X and 1000X magnification; the images were analyzed with an image analyzer. Data were analyzed with one-way ANOVA and Tukey's test at a significance level of p < 0.05. Mean shear bond strength data of the groups in MPa were: Variolink 2/Excite DSC: 25.89 +/- 3.71; Clearfil Esthetic Cement/Clearfil Protect Bond: 17.21 +/- 2.71; Multilink/Multilink Primer: 11.6 +/- 3.51; Multilink Sprint: 10.4 +/- 3.15. According to the one-way ANOVA, there were significant differences in shear bond strength (p < 0.001). According to Tukey's test, statistically significant differences were observed in shear bond strength between groups 1 and 2 (p < 0.001), groups 1 and 3 (p < 0.001), groups 1 and 4 (p < 0.001), groups 2 and 3 (p = 0.003), and groups 2 and 4 (p < 0.001). The etch-and-rinse dentin bonding system produced higher bond strengths of all-ceramics to dentin surfaces than did the self-etching bonding systems and self-adhesive luting system.
- 1 October 2008
- Vol. 10 (5) , 373-8
Bond strength of all-ceramics to tooth structure: using new luting systems.
To examine the effect of different adhesive luting systems on the shear bond strength of all-ceramic restorations to dentin surfaces. Forty-eight all-ceramic disks (2 x 3 mm; IPS e.max Press) were fabricated. Forty-eight noncarious extracted human molars were divided into 4 groups. in groups 1 to 4, IPS e.max Press disks were luted with Variolink 2/Excite DSC (etch-and-rinse), Clearfil Esthetic Cement/Clearfil Protect Bond (antibacterial and self-etching), Multilink/Multilink Primer (self-etching), or Multilink Sprint (self-adhesive). All specimens were subjected to 5000 thermocycles (5 degrees C to 55 degrees C, 30-s dwell time). Shear bond strengths were tested using a universal testing machine until failure. The analysis of the fractured dentin surfaces was performed using an optical microscope at 10X and 1000X magnification; the images were analyzed with an image analyzer. Data were analyzed with one-way ANOVA and Tukey's test at a significance level of p < 0.05. Mean shear bond strength data of the groups in MPa were: Variolink 2/Excite DSC: 25.89 +/- 3.71; Clearfil Esthetic Cement/Clearfil Protect Bond: 17.21 +/- 2.71; Multilink/Multilink Primer: 11.6 +/- 3.51; Multilink Sprint: 10.4 +/- 3.15. According to the one-way ANOVA, there were significant differences in shear bond strength (p < 0.001). According to Tukey's test, statistically significant differences were observed in shear bond strength between groups 1 and 2 (p < 0.001), groups 1 and 3 (p < 0.001), groups 1 and 4 (p < 0.001), groups 2 and 3 (p = 0.003), and groups 2 and 4 (p < 0.001). The etch-and-rinse dentin bonding system produced higher bond strengths of all-ceramics to dentin surfaces than did the self-etching bonding systems and self-adhesive luting system.