STSuna Toksavul

Suna Toksavul

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Suna Toksavul has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • 3D quantification of clinical marginal and internal gap of porcelain laminate veneers with minimal and without tooth preparation and 2-year clinical evaluation

    by Irem Karagözoğlu, Suna Toksavul, Muhittin Toman

    In this in-vivo study, mean and median values of marginal gap and internal adaptation for PLV with minimal tooth preparation and PLVs without tooth preparation were within a clinically acceptable range. A 100% success rate was recorded for all PLV during the 2-year period.


  • Effect of surface conditioning on bond strength between zirconia ceramic and composite resin luting agent

    by Muhittin Toman, Suna Toksavul, Bülent Gökçe, Birgül Özpınar, Atilla Kesercioğlu, Ece Tamaç, Aslı Akın, Levent Özdemir

    • 1 March 2012
      • Vol. 25  (2) , 135-7

    Masticatory performance and mandibular movement patterns of patients with natural dentitions, complete dentures, and implant-supported overdentures.

    by Muhittin Toman, Suna Toksavul, Ahmet Saracoglu, Cenk Cura, Anil Hatipoglu

    The aim of this study was to compare quantitatively the masticatory performance of patients with overdentures supported by two implants, conventional complete dentures, and natural dentitions. Each patient was asked to chew a gelatin cube. The collected remains of the test food (gelatine cube) were fractioned by a sieving procedure and weighed. Maximum mouth opening and masticatory area were measured using kinesiography. There were statistically significant differences among groups with respect to masticatory performance using a 3.15-mm-diameter sieve (P < .001) and 0.5-mm-diameter sieve (P < .001), masticatory area (P = .019), and maximum mouth opening (P < .001). Increasing retention of a mandibular complete denture with two implants improved masticatory performance.


    • 1 March 2010
      • Vol. 18  (1) , 2-7

    Effect of noble metal alloy post and core material on the fracture resistance of endodontically treated teeth.

    by Suna Toksavul, Muhittin Toman, Mehmet Sarikanat, Ibrahim Nergiz, Petra Schmage

    The aim of this study was to investigate the effect of one particular brand of post and core system (ER Post) consisted of different post and core materials on the fracture resistance of endodontically treated teeth. Fifty caries-free maxillary central incisors were randomly assigned to five groups (n=10). All teeth were sectioned at the cemento-enamel junction except for the teeth in the control group. Four experimental groups consisted of cast gold post-and-core group (GG), Heraplat post/cast gold core group (HG), titanium post/composite core (TC), and titanium post/cast gold core (TG). The control group (ETT) consisted of endodontically treated teeth without posts. All posts were cemented in the roots with zinc phosphate cement. Following thermal cycling (5000 cycles between 5 degrees C and 55 degrees C with a dwell time of 30 seconds) a static load was applied to 2 mm below the incisal edge on the palatal surface of each specimen until they were fractured. Fracture data obtained and statistically analyzed with one-way ANOVA and a Tukey's test (p<0.05). Means of the fracture resistance during static loading were: 423.76 N (GG), 529.46 N (HG), 389.08 N (TC), 408.7 N (TG), 404.4 N (ETT, control). Heraplat post with cast gold core exhibited the highest fracture load than the other groups (p<0.05). Specimens in groups HG and ETT (control) showed the most repairable failure. Heraplat post with cast gold core had the highest fracture resistance of endodontically treated teeth.

    • 1 March 2010
      • Vol. 18  (1) , 23-30

    Fracture resistance of endodontically treated teeth: effect of tooth coloured post material and surface conditioning.

    by Muhittin Toman, Suna Toksavul, Mehmet Sarikanat, Ibrahim Nergiz, Petra Schmage

    This in vitro study evaluated the effects of the different endodontic posts and surface conditioning on the fracture resistance and fracture modes of endodontically treated teeth. The experimental groups consisted of zirconia ceramic post with a glasss-ceramic core [A], zirconia ceramic post with a composite core [B], glass fiber composite post (FRC) with a composite core [C], and titanium post with a composite core [D]. All posts in these groups were cemented with self-adhesive resin cement (Rely X Unicem Aplicap) combination with tribochemical silica coating (TSC). Groups E, F, G and H comprised the same post-and-core materials as the first 4 groups but cemented with the same resin cement without TSC. Specimens were subjected to thermal cycling between 5 degrees C and 55 degrees C for a total of 5000 cycles with 30s per cycle. Static load was applied to the palatal surface of each specimen until they were fractured. Statistical analysis was conducted using analysis of variance (ANOVA) followed by post-hoc comparisons (Tukey). The fracture resistance was significantly affected by the post material (P < 0.001) and surface conditioning (P < 0.001; two-way ANOVA). The application of TSC to post surface decreased the fracture resistance of zirconia ceramic post with composite core (p=0.002; Tukey) and glass FRC post with composite core (p=0.029; Tukey). No catastrophic failure was observed for groups B, C, D, E, F and G. Under the testing conditions used, the titanium post/composite core that had been silicoated exhibited the highest fracture resistance.

    • 1 October 2008
      • Vol. 10  (5) , 373-8

    Bond strength of all-ceramics to tooth structure: using new luting systems.

    by Muhittin Toman, Suna Toksavul, Ash Akin

    To examine the effect of different adhesive luting systems on the shear bond strength of all-ceramic restorations to dentin surfaces. Forty-eight all-ceramic disks (2 x 3 mm; IPS e.max Press) were fabricated. Forty-eight noncarious extracted human molars were divided into 4 groups. in groups 1 to 4, IPS e.max Press disks were luted with Variolink 2/Excite DSC (etch-and-rinse), Clearfil Esthetic Cement/Clearfil Protect Bond (antibacterial and self-etching), Multilink/Multilink Primer (self-etching), or Multilink Sprint (self-adhesive). All specimens were subjected to 5000 thermocycles (5 degrees C to 55 degrees C, 30-s dwell time). Shear bond strengths were tested using a universal testing machine until failure. The analysis of the fractured dentin surfaces was performed using an optical microscope at 10X and 1000X magnification; the images were analyzed with an image analyzer. Data were analyzed with one-way ANOVA and Tukey's test at a significance level of p < 0.05. Mean shear bond strength data of the groups in MPa were: Variolink 2/Excite DSC: 25.89 +/- 3.71; Clearfil Esthetic Cement/Clearfil Protect Bond: 17.21 +/- 2.71; Multilink/Multilink Primer: 11.6 +/- 3.51; Multilink Sprint: 10.4 +/- 3.15. According to the one-way ANOVA, there were significant differences in shear bond strength (p < 0.001). According to Tukey's test, statistically significant differences were observed in shear bond strength between groups 1 and 2 (p < 0.001), groups 1 and 3 (p < 0.001), groups 1 and 4 (p < 0.001), groups 2 and 3 (p = 0.003), and groups 2 and 4 (p < 0.001). The etch-and-rinse dentin bonding system produced higher bond strengths of all-ceramics to dentin surfaces than did the self-etching bonding systems and self-adhesive luting system.


    • 26 April 2007
      • Vol. 20  (2) , 168-72

    A short-term clinical evaluation of IPS Empress 2 crowns.

    by Suna Toksavul, Muhittin Toman

    The aim of this study was to evaluate the clinical performance of all-ceramic crowns made with the IPS Empress 2 system after an observation period of 12 to 60 months. Seventy-nine IPS Empress 2 crowns were placed in 21 patients. The all-ceramic crowns were evaluated clinically, radiographically, and using clinical photographs. The evaluations took place at baseline (2 days after cementation) and at 6-month intervals for 12 to 60 months. Survival rate of the crowns was determined using Kaplan-Meier statistical analysis. Based on the US Public Health Service criteria, 95.24% of the crowns were rated satisfactory after a mean follow-up period of 58 months. Fracture was registered in only 1 crown. One endodontically treated tooth failed as a result of fracture at the cervical margin area. In this in vivo study, IPS Empress 2 crowns exhibited a satisfactory clinical performance during an observation period ranging from 12 to 60 months.


    • 1 February 2007
      • Vol. 9  (1) , 39-47

    Influence of luting agent on the microleakage of all-ceramic crowns.

    by Muhittin Toman, Suna Toksavul, Celal Artunç, Murat Türkün, Petra Schmage, Ibrahim Nergiz

    In this in-vitro study, microleakage of all-ceramic crowns was evaluated at enamel and dentin margins. Forty maxillary central incisors were randomly divided into 4 groups (n = 10). While buccal and palatal margins were placed on enamel, mesial and distal margins were placed below the cementoenamel junction. In groups 1 to 3, IPS Empress 2 crowns were luted with Variolink 2/Syntac Classic (group 1), Bifix DC/Solobond Plus (group 2) and Calibra/Prime & Bond NT combinations (group 3), respectively. In the control group (group 4), porcelain-fused-to-metal crowns were luted with a zinc-phosphate cement. All specimens were subjected to 5000 thermocycles (at 5 degrees C to 55 degrees C; 30-s dwell time). After immersion in India ink for 48 h at 37 degrees C, the specimens were sectioned both buccolingually and mesiodistally. Each section was evaluated for microleakage under a stereomicroscope at 24X magnification. According to the Krukal-Wallis test, in all groups, there were significant differences in microleakage at the enamel margins (p = 0.001). Nevertheless, the margins finished in dentin showed no significant differences (p = 0.163). According to the Mann-Whitney U-test, statistically significant differences were observed in microleakage between groups 1 and 3 (p = 0.049), groups 1 and 4 (p = 0.001), groups 2 and 4 (p = 0.002), and between groups 3 and 4 (p = 0.045) at the enamel margin. In group 1, significantly greater microleakage was observed at the dentin margin compared to the enamel margin (p = 0.007). The adhesive luting technique demonstrated an excellent ability to minimize microleakage of all-ceramic crowns at the enamel margins. Water-based dentin bonding systems showed less microleakage than the water-free acetone-based dentin bonding system at the enamel margin.


    • 1 February 2007
      • Vol. 38  (2) , e92-8

    Clinical evaluation of different gingival retraction cords.

    by Ovul Kumbuloglu, Atilla User, Suna Toksavul, Hayal Boyacioglu

    Impression techniques in restorative dentistry require displacement of gingival tissues to expose subgingival finish lines on tooth preparations. Retraction cords are commonly used for this purpose. Some cord systems include various medicaments, which may remain in the sulcus after retraction procedures. The purpose of this study was to determine whether any of the commonly used gingival retraction medicaments could influence the surface characteristics of the impression material and to evaluate the clinical performance of retraction cords. Sixteen cord systems in various shapes, sizes, and medications were used in this study. The clinical performances of cords were evaluated with a blind experimental study design, according to predetermined criteria. Results were analyzed by using chi-square test and ordinal logistic regression analysis (P <.05). Statistically significant differences were found in all criteria among groups (P <.05). None of the materials investigated appeared to have any influence on the surface characterization of the polyvinyl siloxane impression material used. Better impression qualities were observed in groups with easy insertion, proper dilatation, less recurrent bleeding, and no remnants or fraying. Logistic regression analysis revealed that both retraction cord medicaments (odds ratio = 0.63, P = .00 <.05) and cord thicknesses (odds ratio = 2.09, P = .00 <.05) were important risk factors on the gingival margin quality. The applied gingival retraction cord systems had no influence on the surface characterization of the polyvinyl siloxane material tested. Gingival margin quality of the impression and clinical application procedures were affected by the retraction systems. Untreated, medium-braided, and epinephrine-impregnated cord systems were clinically successful. However, the potential systemic effects of epinephrine must be considered.


  • Effect of luting agents and reconstruction techniques on the fracture resistance of pre‐fabricated post systems

    by S. Toksavul, M. Toman, B. Uyulgan, P. Schmage, İ. Nergi̇z

    summary  Fracture resistance and fracture modes of endodontically treated maxillary central incisors restored with different post‐and‐core systems covered with all‐ceramic copings were evaluated. Ten samples were prepared for each group. Groups 1, 2 and 3 consisted of tooth‐coloured post‐and‐core, zirconia post (Cosmopost) with a composite core (Tetric Ceram), zirconia post (Cosmopost) with a custom made ceramic core (Cosmo Ingot), glass fibre‐reinforced post (FRC Postec) with a composite core (Tetric Ceram), respectively. Group 4 consisted of a titanium post (ERpost) with a composite core (Tetric Ceram). The control group (group 5) consisted of root‐filled incisors without posts. Tooth‐coloured posts were cemented in the roots using Variolink‐2, while titanium posts were cemented in the roots using Harvard cement. The all‐ceramic copings were cemented using Variolink‐2. Static load was applied to 2 mm below the incisal edge on the palatinal surface of each sample until they were fractured. Fracture data were obtained and statistically analysed with One‐way anova and a Tukey's test. The results of the means and standard deviations of the fracture resistance during static loading were: 497·5 ± 61·94 (1), 474·61 ± 96·84 (2), 494·61 ± 104·67 (3), 581·34 ± 105·36 (4), 420·42 ± 127·48 (5). There were statistically significant differences between groups 4 and 5. Glass fibre‐reinforced posts and composite cores (group 3) showed the most catastrophic failure. Consequently, zirconia ceramic posts can be used in clinical practice.