Petra Schmage
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Petra Schmage has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Ibrahim Nergiz
Associate Professor, Department of Restorative and Preventive Dentistry, School of Dental and Oral Medicine, University of Hamburg, Hamburg, Germany
7 shared publications - Muhittin Toman
Department of Prosthetic Dentistry, Faculty of Dentistry, Ege University, İzmir, Turkey
3 shared publications - Peter Pfeiffer
Department of Prosthetic Dentistry, School of Oral Medicine, University of Cologne, Cologne, Germany
3 shared publications - Suna Toksavul
Department of Prosthetic Dentistry, Faculty of Dentistry, Ege University, Bornova-Izmir, Turkey
3 shared publications Mehmet Sarikanat
2 shared publicationsThomas M Scorziello
2 shared publications
Latest Publications
- 1 April 2012
- Vol. 14 (2) , 175-182
Resistance Against Pull-out Force of Prefabricated Coated FRC Posts
To investigate the effect of a prefabricated tribochemical coating of FRC (fiber-reinforced composite) posts with and without aging on the pull-out forces compared to posts without conditioning. Post space preparations were performed on 108 extracted anterior teeth. Thirty-six uncoated FRC posts (DentinPost) and 72 prefabricated tribochemically coated FRC posts (DentinPost Coated) were used at a length of 12 mm. Thirty-six of the coated posts were thermally aged. FRC posts (n = 9) were placed using DentinBuild or MultiCore Flow foundation composite resins or Panavia F2.0 or RelyX Unicem resin cements. Following water storage (37°, 24 h) and thermocycling (5000 cycles, 5° to 55°C, 30 s), pull-out force testing was performed. Fracture modes were assessed using a light microscope. Data were analyzed statistically (1-way and 3-way ANOVA, Bonferroni-Dunn correction, α = 0.05). Significantly higher pull-out forces of posts luted with Panavia F2.0 were observed for the coated and coated/aged FRC posts compared to the unconditioned posts (control group, p < 0.001). The pull-out forces of tribochemically coated FRC posts luted with MultiCore Flow were significantly lower than of coated posts luted with Panavia F2.0 (p < 0.001). Coated/aged FRC posts exhibited similar pull-out forces for the tested luting composite resins (p > 0.05). Except for DentinBuild (coated posts), more mixed or cohesive fractures were assessed for coated and coated/aged FRC posts than for unconditioned FRC posts. Prefabricated tribochemical coating of FRC posts provided a stable interface between coating and post and remained stable over time.
- 1 April 2012
- Vol. 14 (2) , 175-182
Resistance Against Pull-out Force of Prefabricated Coated FRC Posts
To investigate the effect of a prefabricated tribochemical coating of FRC (fiber-reinforced composite) posts with and without aging on the pull-out forces compared to posts without conditioning. Post space preparations were performed on 108 extracted anterior teeth. Thirty-six uncoated FRC posts (DentinPost) and 72 prefabricated tribochemically coated FRC posts (DentinPost Coated) were used at a length of 12 mm. Thirty-six of the coated posts were thermally aged. FRC posts (n = 9) were placed using DentinBuild or MultiCore Flow foundation composite resins or Panavia F2.0 or RelyX Unicem resin cements. Following water storage (37°, 24 h) and thermocycling (5000 cycles, 5° to 55°C, 30 s), pull-out force testing was performed. Fracture modes were assessed using a light microscope. Data were analyzed statistically (1-way and 3-way ANOVA, Bonferroni-Dunn correction, α = 0.05). Significantly higher pull-out forces of posts luted with Panavia F2.0 were observed for the coated and coated/aged FRC posts compared to the unconditioned posts (control group, p < 0.001). The pull-out forces of tribochemically coated FRC posts luted with MultiCore Flow were significantly lower than of coated posts luted with Panavia F2.0 (p < 0.001). Coated/aged FRC posts exhibited similar pull-out forces for the tested luting composite resins (p > 0.05). Except for DentinBuild (coated posts), more mixed or cohesive fractures were assessed for coated and coated/aged FRC posts than for unconditioned FRC posts. Prefabricated tribochemical coating of FRC posts provided a stable interface between coating and post and remained stable over time.
- 24 March 2012
- Vol. 27 (2) , 308-17
Effects of 10 cleaning instruments on four different implant surfaces.
The aim of this study was to evaluate the effects of a variety of implant cleaning instruments on different implant surfaces, specifically surface roughness and cleaning efficacy. Biofilm layers of Streptococcus mutans were cultivated on titanium disks with four different surface structures (polished, grit-blasted, acid-etched, and acid-etched/grit-blasted). Five disks each were cleaned using nine mechanical implant cleaning instruments or an erbium:yttrium-aluminum-garnet laser. Surface roughness (average, Ra; maximum, Rz) and waviness (Lr) were evaluated by two-dimensional laser profilometry. Surface structure damage and cleaning scores were assessed by scanning electron microscopy. Statistical analyses of the results were performed with one- and two-way analyses of variance and Bonferroni-Dunn multiple-comparison post hoc analysis (α = .05). Ra and Rz values for the acid-etched surfaces and Ra, Rz, and Lr values for the polished and the grit-blasted surfaces showed no significant differences between the different cleaning methods or cleaning instruments compared to the control (not cultured, not cleaned) groups. Significantly lower Ra and Rz values on grit-blasted/acid-etched implant surfaces were found following use of the Sonic-Flex clean with prophylaxis brush and the plastic curette compared to Satelec ProphyMax with Periosoft curette. Ra and Rz values of the different implant structure surfaces before cleaning were significantly different between all implant surfaces except for the polished compared to the acid-etched surfaces. Cleaning effect and alterations of the implant surfaces were strongly dependent on the implant cleaning method used.
- 24 March 2012
- Vol. 27 (2) , 308-17
Effects of 10 cleaning instruments on four different implant surfaces.
The aim of this study was to evaluate the effects of a variety of implant cleaning instruments on different implant surfaces, specifically surface roughness and cleaning efficacy. Biofilm layers of Streptococcus mutans were cultivated on titanium disks with four different surface structures (polished, grit-blasted, acid-etched, and acid-etched/grit-blasted). Five disks each were cleaned using nine mechanical implant cleaning instruments or an erbium:yttrium-aluminum-garnet laser. Surface roughness (average, Ra; maximum, Rz) and waviness (Lr) were evaluated by two-dimensional laser profilometry. Surface structure damage and cleaning scores were assessed by scanning electron microscopy. Statistical analyses of the results were performed with one- and two-way analyses of variance and Bonferroni-Dunn multiple-comparison post hoc analysis (α = .05). Ra and Rz values for the acid-etched surfaces and Ra, Rz, and Lr values for the polished and the grit-blasted surfaces showed no significant differences between the different cleaning methods or cleaning instruments compared to the control (not cultured, not cleaned) groups. Significantly lower Ra and Rz values on grit-blasted/acid-etched implant surfaces were found following use of the Sonic-Flex clean with prophylaxis brush and the plastic curette compared to Satelec ProphyMax with Periosoft curette. Ra and Rz values of the different implant structure surfaces before cleaning were significantly different between all implant surfaces except for the polished compared to the acid-etched surfaces. Cleaning effect and alterations of the implant surfaces were strongly dependent on the implant cleaning method used.
- 1 March 2010
- Vol. 18 (1) , 2-7
Effect of noble metal alloy post and core material on the fracture resistance of endodontically treated teeth.
The aim of this study was to investigate the effect of one particular brand of post and core system (ER Post) consisted of different post and core materials on the fracture resistance of endodontically treated teeth. Fifty caries-free maxillary central incisors were randomly assigned to five groups (n=10). All teeth were sectioned at the cemento-enamel junction except for the teeth in the control group. Four experimental groups consisted of cast gold post-and-core group (GG), Heraplat post/cast gold core group (HG), titanium post/composite core (TC), and titanium post/cast gold core (TG). The control group (ETT) consisted of endodontically treated teeth without posts. All posts were cemented in the roots with zinc phosphate cement. Following thermal cycling (5000 cycles between 5 degrees C and 55 degrees C with a dwell time of 30 seconds) a static load was applied to 2 mm below the incisal edge on the palatal surface of each specimen until they were fractured. Fracture data obtained and statistically analyzed with one-way ANOVA and a Tukey's test (p<0.05). Means of the fracture resistance during static loading were: 423.76 N (GG), 529.46 N (HG), 389.08 N (TC), 408.7 N (TG), 404.4 N (ETT, control). Heraplat post with cast gold core exhibited the highest fracture load than the other groups (p<0.05). Specimens in groups HG and ETT (control) showed the most repairable failure. Heraplat post with cast gold core had the highest fracture resistance of endodontically treated teeth.
- 1 March 2010
- Vol. 18 (1) , 2-7
Effect of noble metal alloy post and core material on the fracture resistance of endodontically treated teeth.
The aim of this study was to investigate the effect of one particular brand of post and core system (ER Post) consisted of different post and core materials on the fracture resistance of endodontically treated teeth. Fifty caries-free maxillary central incisors were randomly assigned to five groups (n=10). All teeth were sectioned at the cemento-enamel junction except for the teeth in the control group. Four experimental groups consisted of cast gold post-and-core group (GG), Heraplat post/cast gold core group (HG), titanium post/composite core (TC), and titanium post/cast gold core (TG). The control group (ETT) consisted of endodontically treated teeth without posts. All posts were cemented in the roots with zinc phosphate cement. Following thermal cycling (5000 cycles between 5 degrees C and 55 degrees C with a dwell time of 30 seconds) a static load was applied to 2 mm below the incisal edge on the palatal surface of each specimen until they were fractured. Fracture data obtained and statistically analyzed with one-way ANOVA and a Tukey's test (p<0.05). Means of the fracture resistance during static loading were: 423.76 N (GG), 529.46 N (HG), 389.08 N (TC), 408.7 N (TG), 404.4 N (ETT, control). Heraplat post with cast gold core exhibited the highest fracture load than the other groups (p<0.05). Specimens in groups HG and ETT (control) showed the most repairable failure. Heraplat post with cast gold core had the highest fracture resistance of endodontically treated teeth.
- 1 March 2010
- Vol. 18 (1) , 23-30
Fracture resistance of endodontically treated teeth: effect of tooth coloured post material and surface conditioning.
This in vitro study evaluated the effects of the different endodontic posts and surface conditioning on the fracture resistance and fracture modes of endodontically treated teeth. The experimental groups consisted of zirconia ceramic post with a glasss-ceramic core [A], zirconia ceramic post with a composite core [B], glass fiber composite post (FRC) with a composite core [C], and titanium post with a composite core [D]. All posts in these groups were cemented with self-adhesive resin cement (Rely X Unicem Aplicap) combination with tribochemical silica coating (TSC). Groups E, F, G and H comprised the same post-and-core materials as the first 4 groups but cemented with the same resin cement without TSC. Specimens were subjected to thermal cycling between 5 degrees C and 55 degrees C for a total of 5000 cycles with 30s per cycle. Static load was applied to the palatal surface of each specimen until they were fractured. Statistical analysis was conducted using analysis of variance (ANOVA) followed by post-hoc comparisons (Tukey). The fracture resistance was significantly affected by the post material (P < 0.001) and surface conditioning (P < 0.001; two-way ANOVA). The application of TSC to post surface decreased the fracture resistance of zirconia ceramic post with composite core (p=0.002; Tukey) and glass FRC post with composite core (p=0.029; Tukey). No catastrophic failure was observed for groups B, C, D, E, F and G. Under the testing conditions used, the titanium post/composite core that had been silicoated exhibited the highest fracture resistance.
- 1 March 2010
- Vol. 18 (1) , 23-30
Fracture resistance of endodontically treated teeth: effect of tooth coloured post material and surface conditioning.
This in vitro study evaluated the effects of the different endodontic posts and surface conditioning on the fracture resistance and fracture modes of endodontically treated teeth. The experimental groups consisted of zirconia ceramic post with a glasss-ceramic core [A], zirconia ceramic post with a composite core [B], glass fiber composite post (FRC) with a composite core [C], and titanium post with a composite core [D]. All posts in these groups were cemented with self-adhesive resin cement (Rely X Unicem Aplicap) combination with tribochemical silica coating (TSC). Groups E, F, G and H comprised the same post-and-core materials as the first 4 groups but cemented with the same resin cement without TSC. Specimens were subjected to thermal cycling between 5 degrees C and 55 degrees C for a total of 5000 cycles with 30s per cycle. Static load was applied to the palatal surface of each specimen until they were fractured. Statistical analysis was conducted using analysis of variance (ANOVA) followed by post-hoc comparisons (Tukey). The fracture resistance was significantly affected by the post material (P < 0.001) and surface conditioning (P < 0.001; two-way ANOVA). The application of TSC to post surface decreased the fracture resistance of zirconia ceramic post with composite core (p=0.002; Tukey) and glass FRC post with composite core (p=0.029; Tukey). No catastrophic failure was observed for groups B, C, D, E, F and G. Under the testing conditions used, the titanium post/composite core that had been silicoated exhibited the highest fracture resistance.
- 6 June 2009
- Vol. 24 (2) , 289-98
Stability of loaded and unloaded implants with different surfaces.
To compare the torsional strengths and the effects of functional loading on five different implant surface structures. This in vivo longitudinal study of 9 months' duration examined osseointegration in 180 stepped cylindric implants placed into the mandibles of 18 healthy sheepdogs. Implants with five different surface structures were placed (n = 36 in each group): (1) smooth surface; (2) deep profile structure (DPS); (3) titanium plasma sprayed (TPS); (4) hydroxyapatite coated; and (5) sol-gel hydroxyapatite coated (SGHA). All implants were investigated under standardized conditions. At uncovering (3 months), half the implants were loaded with prefabricated crowns for 6 months, and the other half remained unloaded. Removal torque values were evaluated at 3, 6, and 9 months after implant placement. The data were analyzed using analysis of variance and Scheffé correction (alpha < .05). All smooth-surface and SGHA implants failed in succession during the fourth and ninth months of the study. After 3 months the removal torque resistance of DPS, TPS, and hydroxyapatite-coated implants was significantly higher (P < .001) than that seen in the other two groups. Initially, the removal torque resistance of unloaded hydroxyapatite-coated implants was superior, and the decrease during the observation period was not significant. The increase in removal torque resistance under functional loading was not significant for the DPS implants. A significant increase was found in removal torque resistance for the loaded TPS implants (P < .05). The unloaded DPS and TPS implants showed no change in removal torque levels after the closed healing period of 3 months. Successful osseointegration was achieved with DPS, TPS, and hydroxyapatite-coated implants, and smooth-surface and SGHA implants failed. Removal torque resistance was enhanced with controlled functional loading.
- 6 June 2009
- Vol. 24 (2) , 289-98
Stability of loaded and unloaded implants with different surfaces.
To compare the torsional strengths and the effects of functional loading on five different implant surface structures. This in vivo longitudinal study of 9 months' duration examined osseointegration in 180 stepped cylindric implants placed into the mandibles of 18 healthy sheepdogs. Implants with five different surface structures were placed (n = 36 in each group): (1) smooth surface; (2) deep profile structure (DPS); (3) titanium plasma sprayed (TPS); (4) hydroxyapatite coated; and (5) sol-gel hydroxyapatite coated (SGHA). All implants were investigated under standardized conditions. At uncovering (3 months), half the implants were loaded with prefabricated crowns for 6 months, and the other half remained unloaded. Removal torque values were evaluated at 3, 6, and 9 months after implant placement. The data were analyzed using analysis of variance and Scheffé correction (alpha < .05). All smooth-surface and SGHA implants failed in succession during the fourth and ninth months of the study. After 3 months the removal torque resistance of DPS, TPS, and hydroxyapatite-coated implants was significantly higher (P < .001) than that seen in the other two groups. Initially, the removal torque resistance of unloaded hydroxyapatite-coated implants was superior, and the decrease during the observation period was not significant. The increase in removal torque resistance under functional loading was not significant for the DPS implants. A significant increase was found in removal torque resistance for the loaded TPS implants (P < .05). The unloaded DPS and TPS implants showed no change in removal torque levels after the closed healing period of 3 months. Successful osseointegration was achieved with DPS, TPS, and hydroxyapatite-coated implants, and smooth-surface and SGHA implants failed. Removal torque resistance was enhanced with controlled functional loading.
- 1 February 2007
- Vol. 9 (1) , 39-47
Influence of luting agent on the microleakage of all-ceramic crowns.
In this in-vitro study, microleakage of all-ceramic crowns was evaluated at enamel and dentin margins. Forty maxillary central incisors were randomly divided into 4 groups (n = 10). While buccal and palatal margins were placed on enamel, mesial and distal margins were placed below the cementoenamel junction. In groups 1 to 3, IPS Empress 2 crowns were luted with Variolink 2/Syntac Classic (group 1), Bifix DC/Solobond Plus (group 2) and Calibra/Prime & Bond NT combinations (group 3), respectively. In the control group (group 4), porcelain-fused-to-metal crowns were luted with a zinc-phosphate cement. All specimens were subjected to 5000 thermocycles (at 5 degrees C to 55 degrees C; 30-s dwell time). After immersion in India ink for 48 h at 37 degrees C, the specimens were sectioned both buccolingually and mesiodistally. Each section was evaluated for microleakage under a stereomicroscope at 24X magnification. According to the Krukal-Wallis test, in all groups, there were significant differences in microleakage at the enamel margins (p = 0.001). Nevertheless, the margins finished in dentin showed no significant differences (p = 0.163). According to the Mann-Whitney U-test, statistically significant differences were observed in microleakage between groups 1 and 3 (p = 0.049), groups 1 and 4 (p = 0.001), groups 2 and 4 (p = 0.002), and between groups 3 and 4 (p = 0.045) at the enamel margin. In group 1, significantly greater microleakage was observed at the dentin margin compared to the enamel margin (p = 0.007). The adhesive luting technique demonstrated an excellent ability to minimize microleakage of all-ceramic crowns at the enamel margins. Water-based dentin bonding systems showed less microleakage than the water-free acetone-based dentin bonding system at the enamel margin.
- 1 February 2007
- Vol. 9 (1) , 39-47
Influence of luting agent on the microleakage of all-ceramic crowns.
In this in-vitro study, microleakage of all-ceramic crowns was evaluated at enamel and dentin margins. Forty maxillary central incisors were randomly divided into 4 groups (n = 10). While buccal and palatal margins were placed on enamel, mesial and distal margins were placed below the cementoenamel junction. In groups 1 to 3, IPS Empress 2 crowns were luted with Variolink 2/Syntac Classic (group 1), Bifix DC/Solobond Plus (group 2) and Calibra/Prime & Bond NT combinations (group 3), respectively. In the control group (group 4), porcelain-fused-to-metal crowns were luted with a zinc-phosphate cement. All specimens were subjected to 5000 thermocycles (at 5 degrees C to 55 degrees C; 30-s dwell time). After immersion in India ink for 48 h at 37 degrees C, the specimens were sectioned both buccolingually and mesiodistally. Each section was evaluated for microleakage under a stereomicroscope at 24X magnification. According to the Krukal-Wallis test, in all groups, there were significant differences in microleakage at the enamel margins (p = 0.001). Nevertheless, the margins finished in dentin showed no significant differences (p = 0.163). According to the Mann-Whitney U-test, statistically significant differences were observed in microleakage between groups 1 and 3 (p = 0.049), groups 1 and 4 (p = 0.001), groups 2 and 4 (p = 0.002), and between groups 3 and 4 (p = 0.045) at the enamel margin. In group 1, significantly greater microleakage was observed at the dentin margin compared to the enamel margin (p = 0.007). The adhesive luting technique demonstrated an excellent ability to minimize microleakage of all-ceramic crowns at the enamel margins. Water-based dentin bonding systems showed less microleakage than the water-free acetone-based dentin bonding system at the enamel margin.
- 29 July 2004
- Vol. 29 (4) , 404-9
Bending resistance of prefabricated titanium posts following molten cast core attachment.
Posts and cores are used to restore endodontically treated teeth that have substantial loss of the coronal tooth structure. This in vitro study was designed to determine the mechanical properties of prefabricated titanium posts following attachment of their metal cores by molten casting (caston). Prefabricated tapered titanium posts (ER post-restoring system, Komet, Lemgo, Germany) in three diameter sizes (ISO 50, 90, 110) (n=9) were cast over with the metal cores of three different alloys (Au-Ag-Pt, Au-Pt-Pd, Co-Cr-Mo). Also, posts of each size were precision fit into the central core channels of the different cast metal cores to serve as control specimens. The 0.2% yield strengths (R0.2) of all specimens were tested on a universal testing machine. Statistical analyses of the results were carried out with an analysis of variance (ANOVA, one-way, two-way) and Bonferroni-Dunn's multiple comparisons post-hoc analysis for test groups (alpha=0.05). There was a significant decrease in yield strength (p0.05). Prefabricated titanium posts with metal cores cast over them showed inferior mechanical properties compared to precision-fit posts. These results indicate greater strength of the titanium posts when their cast cores were attached mechanically rather than by the molten casting method.
- 29 July 2004
- Vol. 29 (4) , 404-9
Bending resistance of prefabricated titanium posts following molten cast core attachment.
Posts and cores are used to restore endodontically treated teeth that have substantial loss of the coronal tooth structure. This in vitro study was designed to determine the mechanical properties of prefabricated titanium posts following attachment of their metal cores by molten casting (caston). Prefabricated tapered titanium posts (ER post-restoring system, Komet, Lemgo, Germany) in three diameter sizes (ISO 50, 90, 110) (n=9) were cast over with the metal cores of three different alloys (Au-Ag-Pt, Au-Pt-Pd, Co-Cr-Mo). Also, posts of each size were precision fit into the central core channels of the different cast metal cores to serve as control specimens. The 0.2% yield strengths (R0.2) of all specimens were tested on a universal testing machine. Statistical analyses of the results were carried out with an analysis of variance (ANOVA, one-way, two-way) and Bonferroni-Dunn's multiple comparisons post-hoc analysis for test groups (alpha=0.05). There was a significant decrease in yield strength (p0.05). Prefabricated titanium posts with metal cores cast over them showed inferior mechanical properties compared to precision-fit posts. These results indicate greater strength of the titanium posts when their cast cores were attached mechanically rather than by the molten casting method.
- 1 May 2003
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 123 (5) , 540-546
Influence of various surface-conditioning methods on the bond strength of metal brackets to ceramic surfaces
- 1 May 2003
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 123 (5) , 540-546
Influence of various surface-conditioning methods on the bond strength of metal brackets to ceramic surfaces