Dmitry R. Bandura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dmitry R. Bandura has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Vladimir I. Baranov
Institute of Biomaterials and Biomedical Engineering, University of Toronto, Room 407, 164 College Street, Toronto, Ontario, Canada M5S 3G9
3 shared publicationsLinda Liao
MDS Proteomics, 251 Attwell Drive, Toronto, ON, Canada
1 shared publication- Olga I. Ornatsky
Department of Chemistry, University of Toronto, 80 St. George St., Toronto ON, Canada M5S 3H6; DVS Sviences Inc., 70 Peninsula Cr., Richmond Hill, ON L4S1Z5, Canada
1 shared publication Olga Ornatsky
Institute of Biomaterials and Biomedical Engineering, University of Toronto, Room 407, 164 College Street, Toronto, Ontario, Canada M5S 3G9
1 shared publicationScott D. Tanner
Research Department, MDS SCIEX, 71 Four Valley Drive, L4K 4V8, Concord, Ontario, Canada
1 shared publication- Scott D. Tanner
PerkinElmer SCIEX, 71 Four Valley Drive, Concord, Ontario L4K 4V8, Canada
1 shared publication
Latest Publications
- 31 March 2007
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 62 (3) , 188-195
Multiplex bio-assay with inductively coupled plasma mass spectrometry: Towards a massively multivariate single-cell technology
- 31 March 2007
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 62 (3) , 188-195
Multiplex bio-assay with inductively coupled plasma mass spectrometry: Towards a massively multivariate single-cell technology
- 16 December 2003
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 19 (1) , 96-100
Characterization of phosphorus content of biological samples by ICP-DRC-MS: potential tool for cancer research
Phosphorus and sulfur are detected as phosphorus oxide and sulfur oxide ions (PO+ and SO+), produced by oxidation reactions with O2 performed in the reaction cell of the inductively coupled plasma dynamic reaction cell mass spectrometer (ICP-DRC-MS), at sub-ng mL−1 detection limits. This allows pM mL−1 detection of phospho-proteins, with S used as an internal standard (see ref. 9). The method was applied to digests (in HCl) of in-vitro tyrosine kinase assays, both as an evaluation of kinase autophosphorylation and phosphorylation of substrate. Detecting the phosphorus/sulfur ratio (via measured PO+/SO+) in cell cultures is shown to provide a distinguishable difference between malignant cell lines and primary cultures. The PO+/SO+ ratio for human colorectal adenocarcinoma (CRC) tissue samples compared with matched normal (N) tissue samples from the same patients is shown to be higher, at (PO+/SO+)CRC/(PO+/SO+)N = 1.75 ± 0.18 (n = 4). Samples used in this analysis were of needle biopsy amounts (0.2–0.5 mg), with a greater than 70% tumor burden in CRC. The phospho-protein phosvitin is detected directly from dried one-dimensional polyacrylamide gels using laser ablation ICP-MS by detecting phosphorus at sub-nM amounts. The phosphorus detection limit for direct ablation, assessed from ablating gel doped with P and blank gel, is 0.6 µg g−1 in gel. Direct detection of sulfur from the gels is obscured by the high sulfur background for the blank gels, which is attributed to the sulfur-containing catalysts used in polymerization and to sodium dodecyl sulfate (SDS) used for protein denaturing.
- 16 December 2003
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 19 (1) , 96-100
Characterization of phosphorus content of biological samples by ICP-DRC-MS: potential tool for cancer research
Phosphorus and sulfur are detected as phosphorus oxide and sulfur oxide ions (PO+ and SO+), produced by oxidation reactions with O2 performed in the reaction cell of the inductively coupled plasma dynamic reaction cell mass spectrometer (ICP-DRC-MS), at sub-ng mL−1 detection limits. This allows pM mL−1 detection of phospho-proteins, with S used as an internal standard (see ref. 9). The method was applied to digests (in HCl) of in-vitro tyrosine kinase assays, both as an evaluation of kinase autophosphorylation and phosphorylation of substrate. Detecting the phosphorus/sulfur ratio (via measured PO+/SO+) in cell cultures is shown to provide a distinguishable difference between malignant cell lines and primary cultures. The PO+/SO+ ratio for human colorectal adenocarcinoma (CRC) tissue samples compared with matched normal (N) tissue samples from the same patients is shown to be higher, at (PO+/SO+)CRC/(PO+/SO+)N = 1.75 ± 0.18 (n = 4). Samples used in this analysis were of needle biopsy amounts (0.2–0.5 mg), with a greater than 70% tumor burden in CRC. The phospho-protein phosvitin is detected directly from dried one-dimensional polyacrylamide gels using laser ablation ICP-MS by detecting phosphorus at sub-nM amounts. The phosphorus detection limit for direct ablation, assessed from ablating gel doped with P and blank gel, is 0.6 µg g−1 in gel. Direct detection of sulfur from the gels is obscured by the high sulfur background for the blank gels, which is attributed to the sulfur-containing catalysts used in polymerization and to sodium dodecyl sulfate (SDS) used for protein denaturing.
- 1 October 2002
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 13 (10) , 1176-1185
Inductively coupled plasma mass spectrometer with axial field in a quadrupole reaction cell
A novel reaction cell for ICP-MS with an electric field provided inside the quadrupole along its axis is described. The field is implemented via a DC bias applied to additional auxiliary electrodes inserted between the rods of the quadrupole. The field reduces the settling time of the pressurized quadrupole when its mass bandpass is dynamically tuned. It also improves the transmission of analyte ions. It is shown that for the pressurized cell with the field activated, the recovery time for a change in quadrupole operating parameters is reduced to 610 times, respectively. The use of a retarding axial field for in-situ energy discrimination against cluster and polyatomic ions is shown. When the cell is pressurized with O2 for suppression of 129Xe+, the formation of 127IH2+ by reactions with gas impurities limits the detection of 129I to isotopic abundance of approximately 10(-6). In-cell energy discrimination against 127IH2+ utilizing a retarding axial field is shown to reduce the abundance of the background at m/z = 129 to ca. 3 x 10(-8) of the 127I+ signal. In-cell energy discrimination against 127IH2+ is shown to cause less I+ loss than a post-cell potential energy barrier for the same degree of 127IH2+ suppression.
- 1 October 2002
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 13 (10) , 1176-1185
Inductively coupled plasma mass spectrometer with axial field in a quadrupole reaction cell
A novel reaction cell for ICP-MS with an electric field provided inside the quadrupole along its axis is described. The field is implemented via a DC bias applied to additional auxiliary electrodes inserted between the rods of the quadrupole. The field reduces the settling time of the pressurized quadrupole when its mass bandpass is dynamically tuned. It also improves the transmission of analyte ions. It is shown that for the pressurized cell with the field activated, the recovery time for a change in quadrupole operating parameters is reduced to 610 times, respectively. The use of a retarding axial field for in-situ energy discrimination against cluster and polyatomic ions is shown. When the cell is pressurized with O2 for suppression of 129Xe+, the formation of 127IH2+ by reactions with gas impurities limits the detection of 129I to isotopic abundance of approximately 10(-6). In-cell energy discrimination against 127IH2+ utilizing a retarding axial field is shown to reduce the abundance of the background at m/z = 129 to ca. 3 x 10(-8) of the 127I+ signal. In-cell energy discrimination against 127IH2+ is shown to cause less I+ loss than a post-cell potential energy barrier for the same degree of 127IH2+ suppression.
- 18 June 2002
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 17 (9) , 1148-1152
The potential for elemental analysis in biotechnology
The ICP-MS brings particular attributes to the method that distinguishes it from organic mass spectrometry: relative insensitivity to concomitant organic or metallic species, equivalent sensitivity to all similarly-tagged complexes, inherent ability to provide absolute quantitation and linearity of response. All these positive features fit the requirements of modern-day biotechnology. In this work, the potential of ICP-MS is discussed in the context of several urgent problems of biotechnology including: the determination of the state of phosphorylation of proteins, quality control of biologically active materials and control of efficiency of cell line transfections.
- 18 June 2002
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 17 (9) , 1148-1152
The potential for elemental analysis in biotechnology
The ICP-MS brings particular attributes to the method that distinguishes it from organic mass spectrometry: relative insensitivity to concomitant organic or metallic species, equivalent sensitivity to all similarly-tagged complexes, inherent ability to provide absolute quantitation and linearity of response. All these positive features fit the requirements of modern-day biotechnology. In this work, the potential of ICP-MS is discussed in the context of several urgent problems of biotechnology including: the determination of the state of phosphorylation of proteins, quality control of biologically active materials and control of efficiency of cell line transfections.