Harald Keller has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Quantification of local image noise variation in PET images for standardization of noise-dependent analysis metrics

    by R Kueng, B Driscoll, P Manser, M K Fix, M Stampanoni, H Keller

    Purpose. Analysis metrics such as tumor-to-background (T/B) ratios that rely indirectly on local noise properties of a PET image are known to be highly variable depending on image acquisition and image reconstruction parameters. Less well understood are the effects on local image noise arising from correction algorithms that compensate for photon attenuation and detector sensitivity (attenuation and sensitivity corrections). This work investigates these geometry-dependent local noise characteristics in positron emission tomography (PET) images and their implications for the analysis metrics. Methods. Two different phantoms containing homogeneous radioactivity concentrations were scanned for various initial activities and scan times and then reconstructed with a range of reconstruction parameters. Local noise in the form of a local standard deviation was computed and its spatial variation quantified across the PET imaging volume. Results. The local noise variation across the PET image arising from attenuation and sensitivity corrections can be understood with relatively simple analytical models. For fixed reconstruction parameters, the local standard deviation varied up to 60% in the axial direction and up to 30% in trans-axial (radial) direction. Varying the initial activity concentration and the scan time confirmed that the local noise obeys almost perfect Poisson statistics. As a consequence, depending on the spatial location of the volumes of interest, the T/B metrics can vary more than 30%. In addition, the local standard deviation showed substantial variation up to an order of magnitude (factor 10) for different reconstruction parameters. Conclusion. Quantifying the spatial variation of the geometry-dependent local noise across the imaging volume of a particular PET scanner allows us to develop quantitative correction algorithms for standardizing image analysis using noise-dependent metrics.


  • Technical Note: Enhancing the surface dose using a weak longitudinal magnetic field

    by Marco Carlone, Tony Tadic, Harald Keller, Mohammad Rezaee, David Jaffray


  • A novel dose-volume metric for optimizing therapeutic ratio through fractionation: Retrospective analysis of lung cancer treatments

    by Harald Keller, Andrew Hope, Gabriel Meier, Matt Davison

    To explore the potential of a novel dose-volume based metric to assist in the selection of optimal fractionation schedules for lung cancer patients. Selecting the dose per fraction that maximizes the therapeutic ratio via a linear-quadratic effect on normal tissue complication probability and tumor cell survival is an optimization problem. The mathematical solution reveals that the optimal fractionation schedule is determined by a generalized dose ratio between the normal tissue and the tumor, here termed the bifurcation number B, that can be derived from the dose-volume histogram of the normal tissue. The bifurcation number characterizes the volume effect of a normal tissue and its dependency on the fractionation schedule. The clinical relevance of the bifurcation number was evaluated in 46 patients previously treated for nonsmall cell lung cancer (NSCLC) according to various fractionation protocols. Bifurcation numbers were computed for both lung and esophagus as the normal tissues. The value of the bifurcation number determines whether the volume effect reverses the traditional radiobiological advantage of small dose per fraction for the normal tissue. If B is smaller than the ratio of alpha/beta ratios between normal tissue and tumor, then a single fraction is optimal; otherwise the optimal treatment is an infinite number of doses (hence the name "bifurcation" number). These fractionation schedules correspond clinically to hypo- and standard/hyperfractionation, respectively. Compared with traditional dose-volume metrics, the bifurcation number is a unitless ratio and independent of dose fractionation. The B-numbers derived from the clinical treatment plans are also strongly consistent with historically prescribed clinical fractionation protocols for NSCLC treatments. The B-numbers for esophagus and lung for all patients receiving a high dose per fraction protocol (>7.5 Gy/fraction) were all smaller than the B-numbers for the patients receiving standard 2 Gy/fraction, with the numbers for the 3 Gy/fraction group in between. The bifurcation numbers are strongly consistent with prescribed clinical fractionation protocols for NSCLC treatments. Due to their scale-free property the B-numbers may assist in the selection of an appropriate fractionation once the dose distribution has been optimized.


  • Radiotherapy Dose Fractionation under Parameter Uncertainty

    by Matt Davison, Daero Kim, Harald Keller, Ilias Kotsireas, Roderick Melnik, Brian West

    In radiotherapy,radiation is directed to damage a tumor while avoiding surrounding healthy tissue. Tradeoffs ensue because dose cannot be exactly shaped to the tumor. It is particularly important to ensure that sensitive biological structures near the tumor are not damaged more than a certain amount. Biological tissue is known to have a nonlinear response to incident radiation. The linear quadratic dose response model, which requires the specification of two clinically and experimentally observed response coefficients, is commonly used to model this effect. This model yields an optimization problem giving two different types of optimal dose sequences (fractionation schedules). Which fractionation schedule is preferred depends on the response coefficients. These coefficients are uncertainly known and may differ from patient to patient. Because of this not only the expected outcomes but also the uncertainty around these outcomes are important, and it might not be prudent to select the strategy with the best expected outcome.


  • Efficient on‐line setup correction strategies using plan‐intent functions

    by Harry Keller, David A. Jaffray, Tara Rosewall, Elizabeth White

    With the introduction of image-guided radiation therapy (IGRT) delivery systems on-line set-up correction strategies have gained in popularity. Usually, the correction workload of these strategies is high compared to off-line strategies as daily setup corrections have to be performed based on a predefined action level. In this work, it is proposed that on-line strategies must not only be judged in terms of workload but also in terms of efficacy. While workload can be easily predicted for such strategies, the efficacy must ultimately reflect the efficiency with which the original treatment plan intent is met. The purpose of this work is to investigate the tradeoff between workload and efficacy of three different on-line set-up correction strategies: The common fixed action level strategy and two novel on-line setup correction strategies, i.e., a dose-volume histogram (DVH) constraint and an equivalent uniform dose (EUD) score strategy that aim directly for better compliance with original treatment plan intent. All strategies were reformulated in terms of a score function that reflected treatment plan intent. A retrospective study was conducted on 5 prostate patients (7-field conformal, 79.8 Gy, 42 fractions). PTV margins were 10 mm except in the posterior direction (7 mm). The original treatment plan intent for these patients was defined using a set of DVH constraints. The results show that the on-line setup correction strategy based on a fixed action level of 3 mm resulted in a considerable correction workload. For larger action levels, a dose benefit (in terms of EUD) in the rectum and bladder was observed for all patients which is clinically "fortuitous" but difficult to take advantage of. In contrast, the application of the two novel strategies generally resulted in a controlled decrease of the dose to the rectum and the bladder with a smaller workload. It is concluded that using information about target anatomy and the planned dose distribution allows the design of specific correction strategies that are better tailored to the individual patient and that comply effectively with initial treatment plan intent.