  • Institutional experience with a rotational total skin electron irradiation (RTSEI) technique—A three decade review (1981–2012)

    by Michael D.C. Evans, Christine Hudon, Ervin B. Podgorsak, Carolyn R. Freeman

    Total skin electron irradiation (TSEI) for patients with cutaneous lymphomas is technically challenging, and numerous approaches have been developed to overcome the many field matching problems associated with such a large and complex treatment volume. Since 1981 we have delivered TSEI using a rotational total skin electron irradiation (RTSEI) technique in conjunction with patch, treat and boost fields in order to provide complete skin and dose coverage. Initially we used a 6 MeV electron beam at an extended source-skin distance (SSD) on a modified linear accelerator. More recently we began using a high dose rate electron mode on a commercially available linear accelerator. The RTSEI technique allows the delivery of a seamless surface dose to the majority of the patient's skin surface in a single treatment. In this review paper we present our three-decade experience with the technical development, dosimetry, treatment delivery and clinical outcomes of our RTSEI technique.


  • Clinic based transfer of the calibration coefficient using a linear accelerator

    by W. Abdel‐Rahman, M. D. C. Evans, L. Serré, J. P. McCaffrey, E. B. Podgorsak, J. P. Seuntjens

    Ionization chambers used for reference dosimetry require a local secondary standard ionization chamber with a 60Co absorbed dose to water calibration coefficient N(D,W)(60Co) traceable to a national primary standards dosimetry laboratory or an accredited secondary dosimetry calibration laboratory. Clinic based (in-house) transfer of this coefficient to tertiary reference ionization chambers has traditionally been accomplished with chamber cross calibration in water using a 60Co beam; however, access to 60Co teletherapy machines has become increasingly limited for clinic based physicists. In this work, the accuracy of alternative methods of transferring the N(D,W)(60Co) calibration coefficient using 6 and 18 MV photon beams from a linear accelerator in lieu of 60Co has been investigated for five different setups and four commonly used chamber types.


  • Open Access

    Total body irradiation with a reconditioned cobalt teletherapy unit

    by Michael D.C. Evans, Renée-Xavière Larouche, Marina Olivares, Pierre Léger, Joe Larkin, Carolyn R. Freeman, Ervin B. Podgorsak


  • A monitor unit “odometer” for measuring linac workload

    by M. D. C. Evans, J. J. Larkin, P. Léger, E. B. Podgorsak

    The annual linac workload is often required by regulatory agencies to assess compliance with license conditions. Summation of the monitor units produced by the machine is generally used for this purpose. Various methods of estimating this value have inherent inaccuracies. We have built an integrating Monitor Unit "odometer" that is able to automatically accumulate all MUs delivered by the linac and segregate the total by mode (photon or electron) and energy. The device has been used to record clinical linac MU workloads for 10 months, and was installed in a new dual-energy linac during the acceptance and commissioning process.


  • Detecting electron beam energy shifts with a commercially available energy monitor

    by Michael D. C. Evans, Belal A. Moftah, Marina Olivares, Ervin B. Podgorsak

    Routine electron beam quality assurance requires an accurate, yet practical, method of energy characterization. Subtle shifts in beam energy may be produced by the linac bending magnet assembly, and the sensitivity of a commercially available electron beam energy‐monitoring device for monitoring these small energy drifts has been evaluated. The device shows an 11% change in signal for a 2 mm change in the energy parameter for low energy electron beams (in the vicinity of 6 MeV) and a 2.5% change in signal for a 2 mm change in the energy parameter for high energy electron beams (in the vicinity of 22 MeV). Thus the device is capable of detecting small energy shifts resulting from bending magnet drift for all clinically relevant electron beams.


  • Verification of the correspondence between CT-simulated and treatment beams

    by B. G. Fallone, M. D. C. Evans, B. G. Clark, E. B. Podgorsak

    A single phantom technique has been developed to verify the full CT simulation and treatment-beam delivery procedures. The phantom consists of a target delineated by thin copper strips, affixed to therapy verification film, and inserted securely between two slices of water-equivalent material. The target is defined with the aid of the copper strips, and the position of the isocenter and beam parameters such as field size, and gantry and collimator angle are determined by CT simulation. With these parameters, the phantom is subsequently irradiated by the linear accelerator in the treatment position. Correspondence between the planned and the irradiated region is determined by the position of the copper strips on the film. The technique is a simple and practical method for verifying the entire CT simulation and treatment-beam delivery processes, and provides a permanent record of the correspondence between the planning digitally reconstructed radiographs (DRR) and the actual beam delivered.


  • Long source–skin distance rectal irradiation technique: a review of results

    by G Shenouda, P H Gordon, E B Podgorsak, M D C Evans, C R Freeman

    Endocavitary rectal irradiation is a well established curative treatment for patients with selected early cases of adenocarcinoma of the rectum. At McGill we use a long source-skin distance (SSD) rectal irradiation technique as an alternative to the standard short SSD rectal irradiation technique originally described by Papillon. Eight patients, seven women and one man, were treated between April 1986 and November 1988. Median age was 72.5 years (range 46-86 years). Seven patients were treated with curative intent, and one for palliation. The mean follow-up period for all patients was 43 months, with a median of 54 months (range 3-65 months). Actuarial survival and disease-free survival were 86% and 72% at 65 months for the seven patients treated with curative intent. Treatments were well tolerated by all patients and only one patient developed localized proctitis that required steroid enemas, which resulted in complete resolution of symptoms. Our results are comparable with those in other reports in the literature. The complications were similar in type and frequency to other published series.