Dean C. Ripple
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dean C. Ripple has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Wyatt N. Vreeland
National Institute of Standards and Technology, Gaithersburg, MD 20899, USA
2 shared publications Zhishang Hu
Center for Computational and Systems Biology, Institute of Biophysics, Chinese Academy of Sciences, Beijing, China
2 shared publications- Adam W. York
Protein and Cell Analysis, Thermo Fisher Scientific, Eugene, OR 97402, USA
1 shared publication - Adolfas K. Gaigalas
Biosystems and Biomaterials Division, National Institute of Standards and Technology (NIST), Gaithersburg, MD 20899, USA
1 shared publication - Anne A. Galyean
Gillings School of Global Public Health, Department of Environmental Sciences and Engineering, University of North Carolina, Chapel Hill, NC 27599, USA
1 shared publication - B. Carol Johnson
National Institute of Standards and Technology
1 shared publication
Latest Publications
- Open Access
- 8 September 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (18) , 3118
Number Concentration Measurements of Polystyrene Submicrometer Particles
The number of techniques to measure number concentrations and size distributions of submicrometer particles has recently increased. Submicrometer particle standards are needed to improve the accuracy and reproducibility of these techniques. The number concentrations of fluorescently labeled polystyrene submicrometer sphere suspensions with nominal 100 nm, 200 nm and 500 nm diameters were measured using seven different techniques. Diameter values were also measured where possible. The diameter values were found to agree within 20%, but the number concentration values differed by as much as a factor of two. Accuracy and reproducibility related with the different techniques are discussed with the goal of using number concentration standards for instrument calibration. Three of the techniques were used to determine SI-traceable number concentration values, and the three independent values were averaged to give consensus values. This consensus approach is proposed as a protocol for certifying SI-traceable number concentration standards.
- 8 September 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (18) , 3118
Open AccessNumber Concentration Measurements of Polystyrene Submicrometer Particles
The number of techniques to measure number concentrations and size distributions of submicrometer particles has recently increased. Submicrometer particle standards are needed to improve the accuracy and reproducibility of these techniques. The number concentrations of fluorescently labeled polystyrene submicrometer sphere suspensions with nominal 100 nm, 200 nm and 500 nm diameters were measured using seven different techniques. Diameter values were also measured where possible. The diameter values were found to agree within 20%, but the number concentration values differed by as much as a factor of two. Accuracy and reproducibility related with the different techniques are discussed with the goal of using number concentration standards for instrument calibration. Three of the techniques were used to determine SI-traceable number concentration values, and the three independent values were averaged to give consensus values. This consensus approach is proposed as a protocol for certifying SI-traceable number concentration standards.
- 17 June 2019
- Published by Parenteral Drug Association, Inc. in PDA Journal of Pharmaceutical Science and Technology
- Vol. 73 (5) , 418-432
Development of Protein-Like Reference Material for Semiquantitatively Monitoring Visible Proteinaceous Particles in Biopharmaceuticals
Visible particles may potentially pose safety and efficacy concerns if inadvertently administered to patients; therefore, it is crucial to monitor and characterize these particles. These particles may be composed of proteinaceous and non-proteinaceous material. While particles made of non-proteinaceous material are unacceptable in drug products, proteinaceous particles may be acceptable on a case-by-case basis if characterized and shown not to pose quality, efficacy, and safety concerns. The focus of this manuscript is on the proteinaceous particles that may potentially form in some biopharmaceuticals. Monitoring and tracking proteinaceous particles in these biotherapeutics can be challenging but a universal protein-like particle standard might be able to help. The aim of this work is to evaluate abraded ethylene tetrafluoroethylene (ETFE) as a visible protein-like particle standard and demonstrate a semi-quantitative method to show how this surrogate can be used to effectively monitor proteinaceous particles during formulation and analytical development. Studies indicated that the ETFE particles in solution better mimic the appearance and behavior of protein particles than commonly used polystyrene microsphere standards and therefore could be a viable standard for visible proteinaceous particles. Such standards and the semi-quantitative method illustrated could be used effectively during development to non-destructively identify potential stability problems.
- 17 June 2019
- Published by Parenteral Drug Association, Inc. in PDA Journal of Pharmaceutical Science and Technology
- Vol. 73 (5) , 418-432
Development of Protein-Like Reference Material for Semiquantitatively Monitoring Visible Proteinaceous Particles in Biopharmaceuticals
Visible particles may potentially pose safety and efficacy concerns if inadvertently administered to patients; therefore, it is crucial to monitor and characterize these particles. These particles may be composed of proteinaceous and non-proteinaceous material. While particles made of non-proteinaceous material are unacceptable in drug products, proteinaceous particles may be acceptable on a case-by-case basis if characterized and shown not to pose quality, efficacy, and safety concerns. The focus of this manuscript is on the proteinaceous particles that may potentially form in some biopharmaceuticals. Monitoring and tracking proteinaceous particles in these biotherapeutics can be challenging but a universal protein-like particle standard might be able to help. The aim of this work is to evaluate abraded ethylene tetrafluoroethylene (ETFE) as a visible protein-like particle standard and demonstrate a semi-quantitative method to show how this surrogate can be used to effectively monitor proteinaceous particles during formulation and analytical development. Studies indicated that the ETFE particles in solution better mimic the appearance and behavior of protein particles than commonly used polystyrene microsphere standards and therefore could be a viable standard for visible proteinaceous particles. Such standards and the semi-quantitative method illustrated could be used effectively during development to non-destructively identify potential stability problems.
- 11 January 2018
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 123, 1-21
Primary Determination of Particle Number Concentration with Light Obscuration and Dynamic Imaging Particle Counters
Accurate number concentrations of particles in liquid media are needed to assess the quality of water, pharmaceuticals, and other liquids, yet there are limited reference materials or calibration services available with clear traceability to the International System of Units. We describe two methods, based on very simple modifications of commercial particle counter instruments, that can provide traceable number concentration measurements. One method used a light obscuration counter. Fitting a model to the data enabled correction for timing and coincidence errors, and gravimetric calibration of the syringe pump gave a traceable determination of measured volume. Other potential biases were diagnosed by analysis of the particle size distribution. The other method used a dynamic imaging particle counter (a flow imaging microscope). The instrument was intentionally configured so that each particle passing through the flow cell was imaged multiple times. Following the particle image acquisition runs, runs with a rinse solution released and counted microspheres adsorbed to tubing or flow-cell walls. Software assembled the redundant particle images into tracks, and the total number of tracks was assigned as the number of particles counted. Both light obscuration and dynamic imaging methods, when applied to polystyrene microspheres of approximately 4 μm diameter, achieved expanded uncertainties (k = 2) of approximately 2 % of number concentration and agreed to within a difference of 1.1 %.
- 11 January 2018
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 123, 1-21
Primary Determination of Particle Number Concentration with Light Obscuration and Dynamic Imaging Particle Counters
Accurate number concentrations of particles in liquid media are needed to assess the quality of water, pharmaceuticals, and other liquids, yet there are limited reference materials or calibration services available with clear traceability to the International System of Units. We describe two methods, based on very simple modifications of commercial particle counter instruments, that can provide traceable number concentration measurements. One method used a light obscuration counter. Fitting a model to the data enabled correction for timing and coincidence errors, and gravimetric calibration of the syringe pump gave a traceable determination of measured volume. Other potential biases were diagnosed by analysis of the particle size distribution. The other method used a dynamic imaging particle counter (a flow imaging microscope). The instrument was intentionally configured so that each particle passing through the flow cell was imaged multiple times. Following the particle image acquisition runs, runs with a rinse solution released and counted microspheres adsorbed to tubing or flow-cell walls. Software assembled the redundant particle images into tracks, and the total number of tracks was assigned as the number of particles counted. Both light obscuration and dynamic imaging methods, when applied to polystyrene microspheres of approximately 4 μm diameter, achieved expanded uncertainties (k = 2) of approximately 2 % of number concentration and agreed to within a difference of 1.1 %.
- 10 November 2015
- Published by Springer Nature in Pharmaceutical Research
- Vol. 33 (3) , 653-672
Correcting the Relative Bias of Light Obscuration and Flow Imaging Particle Counters
Purpose Industry and regulatory bodies desire more accurate methods for counting and characterizing particles. Measurements of proteinaceous-particle concentrations by light obscuration and flow imaging can differ by factors of ten or more. Methods We propose methods to correct the diameters reported by light obscuration and flow imaging instruments. For light obscuration, diameters were rescaled based on characterization of the refractive index of typical particles and a light scattering model for the extinction efficiency factor. The light obscuration models are applicable for either homogeneous materials (e.g., silicone oil) or for chemically homogeneous, but spatially non-uniform aggregates (e.g., protein aggregates). For flow imaging, the method relied on calibration of the instrument with silica beads suspended in water-glycerol mixtures. Results These methods were applied to a silicone-oil droplet suspension and four particle suspensions containing particles produced from heat stressed and agitated human serum albumin, agitated polyclonal immunoglobulin, and abraded ethylene tetrafluoroethylene polymer. All suspensions were measured by two flow imaging and one light obscuration apparatus. Prior to correction, results from the three instruments disagreed by a factor ranging from 3.1 to 48 in particle concentration over the size range from 2 to 20 μm. Bias corrections reduced the disagreement from an average factor of 14 down to an average factor of 1.5. Conclusions The methods presented show promise in reducing the relative bias between light obscuration and flow imaging.
- 10 November 2015
- Published by Springer Nature in Pharmaceutical Research
- Vol. 33 (3) , 653-672
Correcting the Relative Bias of Light Obscuration and Flow Imaging Particle Counters
Purpose Industry and regulatory bodies desire more accurate methods for counting and characterizing particles. Measurements of proteinaceous-particle concentrations by light obscuration and flow imaging can differ by factors of ten or more. Methods We propose methods to correct the diameters reported by light obscuration and flow imaging instruments. For light obscuration, diameters were rescaled based on characterization of the refractive index of typical particles and a light scattering model for the extinction efficiency factor. The light obscuration models are applicable for either homogeneous materials (e.g., silicone oil) or for chemically homogeneous, but spatially non-uniform aggregates (e.g., protein aggregates). For flow imaging, the method relied on calibration of the instrument with silica beads suspended in water-glycerol mixtures. Results These methods were applied to a silicone-oil droplet suspension and four particle suspensions containing particles produced from heat stressed and agitated human serum albumin, agitated polyclonal immunoglobulin, and abraded ethylene tetrafluoroethylene polymer. All suspensions were measured by two flow imaging and one light obscuration apparatus. Prior to correction, results from the three instruments disagreed by a factor ranging from 3.1 to 48 in particle concentration over the size range from 2 to 20 μm. Bias corrections reduced the disagreement from an average factor of 14 down to an average factor of 1.5. Conclusions The methods presented show promise in reducing the relative bias between light obscuration and flow imaging.
- 1 July 2015
- Published by Elsevier in Analytica Chimica Acta
- Vol. 886, 207-213
Using light scattering to evaluate the separation of polydisperse nanoparticles
- 1 July 2015
- Published by Elsevier in Analytica Chimica Acta
- Vol. 886, 207-213
Using light scattering to evaluate the separation of polydisperse nanoparticles
- 1 December 2014
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 119, 644-82
The Use of Index-Matched Beads in Optical Particle Counters
In this paper, we demonstrate the use of 2-pyridinemethanol (2P) aqueous solutions as a refractive index matching liquid. The high refractive index and low viscosity of 2P-water mixtures enables refractive index matching of beads that cannot be index matched with glycerol-water or sucrose-water solutions, such as silica beads that have the refractive index of bulk fused silica or of polymethylmethacrylate beads. Suspensions of beads in a nearly index-matching liquid are a useful tool to understand the response of particle counting instruments to particles of low optical contrast, such as aggregated protein particles. Data from flow imaging and light obscuration instruments are presented for bead diameters ranging from 6 µm to 69 µm, in a matrix liquid spanning the point of matched refractive index.
- 1 December 2014
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 119, 644-82
The Use of Index-Matched Beads in Optical Particle Counters
In this paper, we demonstrate the use of 2-pyridinemethanol (2P) aqueous solutions as a refractive index matching liquid. The high refractive index and low viscosity of 2P-water mixtures enables refractive index matching of beads that cannot be index matched with glycerol-water or sucrose-water solutions, such as silica beads that have the refractive index of bulk fused silica or of polymethylmethacrylate beads. Suspensions of beads in a nearly index-matching liquid are a useful tool to understand the response of particle counting instruments to particles of low optical contrast, such as aggregated protein particles. Data from flow imaging and light obscuration instruments are presented for bead diameters ranging from 6 µm to 69 µm, in a matrix liquid spanning the point of matched refractive index.
- 1 October 2012
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 101 (10) , 3568-3579
Protein particles: What we know and what we do not know
- 1 October 2012
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 101 (10) , 3568-3579
Protein particles: What we know and what we do not know
- 12 October 2010
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 33 (8-9) , 1477-1487
A Humidity Generator for Temperatures up to 200 °C and Pressures up to 1.6 MPa
- 12 October 2010
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 33 (8-9) , 1477-1487
A Humidity Generator for Temperatures up to 200 °C and Pressures up to 1.6 MPa
- 8 September 2007
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 28 (6) , 1789-1799
Acoustic Thermometry Results from 271 to 552 K
- 8 September 2007
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 28 (6) , 1789-1799
Acoustic Thermometry Results from 271 to 552 K
- 1 March 2006
- Published by NCSL International in NCSLI Measure
- Vol. 1 (1) , 28-34
Uncertainty Budgets for Comparison Calibrations of Thermocouples
By means of concrete examples, we discuss the determination of an uncertainty budget for calibration of thermocouples by comparison techniques. In the first example, the calibration of a type T thermocouple (copper versus copper-nickel alloy) in a stirred liquid bath with a platinum resistance thermometer as a reference is considered. The second example is the calibration of a type K (a nickel-chromium versus nickel-aluminum alloy) thermocouple at temperatures up to 1200 °C in a tube furnace, using a platinum-rhodium alloy thermocouple as a reference. Methods for determining the magnitudes of these uncertainties are given for each uncertainty component.
- 1 March 2006
- Published by NCSL International in NCSLI Measure
- Vol. 1 (1) , 28-34
Uncertainty Budgets for Comparison Calibrations of Thermocouples
By means of concrete examples, we discuss the determination of an uncertainty budget for calibration of thermocouples by comparison techniques. In the first example, the calibration of a type T thermocouple (copper versus copper-nickel alloy) in a stirred liquid bath with a platinum resistance thermometer as a reference is considered. The second example is the calibration of a type K (a nickel-chromium versus nickel-aluminum alloy) thermocouple at temperatures up to 1200 °C in a tube furnace, using a platinum-rhodium alloy thermocouple as a reference. Methods for determining the magnitudes of these uncertainties are given for each uncertainty component.