Adam W. York
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Adam W. York has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Adolfas K. Gaigalas
Biosystems and Biomaterials Division, National Institute of Standards and Technology (NIST), Gaithersburg, MD 20899, USA
1 shared publication - Dean C. Ripple
National Institute of Standards and Technology
1 shared publication - Elzafir B. Elsheikh
Biosystems and Biomaterials Division, National Institute of Standards and Technology (NIST), Gaithersburg, MD 20899, USA
1 shared publication - Eric J. Welch
Protein and Cell Analysis, Thermo Fisher Scientific, Eugene, OR 97402, USA
1 shared publication - Kurt D. Benkstein
Biomolecular Measurement Division, National Institute of Standards and Technology (NIST), Gaithersburg, MD 20899, USA
1 shared publication - Lili Wang
Biosystems and Biomaterials Division, Material Measurement Laboratory, National Institute of Standards and Technology (NIST), United States
1 shared publication
Latest Publications
- Open Access
- 8 September 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (18) , 3118
Number Concentration Measurements of Polystyrene Submicrometer Particles
The number of techniques to measure number concentrations and size distributions of submicrometer particles has recently increased. Submicrometer particle standards are needed to improve the accuracy and reproducibility of these techniques. The number concentrations of fluorescently labeled polystyrene submicrometer sphere suspensions with nominal 100 nm, 200 nm and 500 nm diameters were measured using seven different techniques. Diameter values were also measured where possible. The diameter values were found to agree within 20%, but the number concentration values differed by as much as a factor of two. Accuracy and reproducibility related with the different techniques are discussed with the goal of using number concentration standards for instrument calibration. Three of the techniques were used to determine SI-traceable number concentration values, and the three independent values were averaged to give consensus values. This consensus approach is proposed as a protocol for certifying SI-traceable number concentration standards.
- 8 September 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (18) , 3118
Open AccessNumber Concentration Measurements of Polystyrene Submicrometer Particles
The number of techniques to measure number concentrations and size distributions of submicrometer particles has recently increased. Submicrometer particle standards are needed to improve the accuracy and reproducibility of these techniques. The number concentrations of fluorescently labeled polystyrene submicrometer sphere suspensions with nominal 100 nm, 200 nm and 500 nm diameters were measured using seven different techniques. Diameter values were also measured where possible. The diameter values were found to agree within 20%, but the number concentration values differed by as much as a factor of two. Accuracy and reproducibility related with the different techniques are discussed with the goal of using number concentration standards for instrument calibration. Three of the techniques were used to determine SI-traceable number concentration values, and the three independent values were averaged to give consensus values. This consensus approach is proposed as a protocol for certifying SI-traceable number concentration standards.