Karl-Heinz Hiller
Research Subjects
Research Interests
Karl-Heinz Hiller has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Axel Haase
Technische Universität München, Munich, Germany
3 shared publications - Christiane Waller
Medizinische Universitätsklinik, Würzburg, Germany
2 shared publications Eberhard Rommel
2 shared publications- Frank Wiesmann
Medizinische Universitätsklinik Würzburg, Germany
2 shared publications - Jörg U.G. Streif
Physikalisches Institut, Lehrstuhl für Experimentelle Physik V (Biophysik), Universität Würzburg, Am Hubland, Würzburg, Germany
2 shared publications - Matthias Nahrendorf
Center for Systems Biology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
2 shared publications
Latest Publications
- 18 September 2011
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 25 (3) , 215-222
Contrast agent derived determination of the total circulating blood volume using magnetic resonance
Knowledge of the total circulating blood volume (TCBV) is essential for the treatment of a variety of medical conditions and blood disorders. To date, blood volume analysis is rarely carried out due to the disadvantages of available methods. Our aim was to develop a widely available, simple, fast, yet accurate method for the determination of the total circulating blood volume. Magnetic resonance (MR) is a well-established, non-invasive technique. In this article, we present a method that uses MR contrast agents for the determination of the blood volume. The dependence of MR relaxation times on the concentration of MR contrast agents allows the calculation of the volume the contrast agent has been diluted in. In phantom and in vivo experiments we could demonstrate that TCBV can be determined with high accuracy and precision. This work introduces a novel method for the determination of the total circulating blood volume using magnetic resonance contrast agents as tracers.
- 18 September 2011
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 25 (3) , 215-222
Contrast agent derived determination of the total circulating blood volume using magnetic resonance
Knowledge of the total circulating blood volume (TCBV) is essential for the treatment of a variety of medical conditions and blood disorders. To date, blood volume analysis is rarely carried out due to the disadvantages of available methods. Our aim was to develop a widely available, simple, fast, yet accurate method for the determination of the total circulating blood volume. Magnetic resonance (MR) is a well-established, non-invasive technique. In this article, we present a method that uses MR contrast agents for the determination of the blood volume. The dependence of MR relaxation times on the concentration of MR contrast agents allows the calculation of the volume the contrast agent has been diluted in. In phantom and in vivo experiments we could demonstrate that TCBV can be determined with high accuracy and precision. This work introduces a novel method for the determination of the total circulating blood volume using magnetic resonance contrast agents as tracers.
- 1 August 2011
- Published by Springer Nature
- Vol. 771, 407-420
Plaque Imaging in Murine Models of Cardiovascular Disease
Comprehensive imaging of the cardiovascular system of murine models of atherosclerosis requires high spatial and temporal resolution as well as a high soft tissue contrast. High-field (≥7 T) experimental magnetic resonance imaging can provide noninvasive, high-resolution images of the murine cardiovascular system. High-field scanners, however, require special equipment and imaging protocols. The aim of this chapter is to provide instructions on how to obtain morphological and functional data on the murine cardiovascular system in animal models of atherosclerotic disease on a very high-field scanner (17.6 T). Equipment requirements are presented, and a comprehensive description of the methods needed to complete a magnetic resonance imaging exam, including the animal preparation, imaging, and image analysis are discussed. In addition, common problems during high-field MRI experiments and methods to validate MRI results are reviewed. The steps can be adopted to other MRI scanners and modification of the imaging parameters might allow for a more individual assessment of cardiovascular diseases in a number of transgenic mouse models.
- 1 August 2011
- Published by Springer Nature
- Vol. 771, 407-420
Plaque Imaging in Murine Models of Cardiovascular Disease
Comprehensive imaging of the cardiovascular system of murine models of atherosclerosis requires high spatial and temporal resolution as well as a high soft tissue contrast. High-field (≥7 T) experimental magnetic resonance imaging can provide noninvasive, high-resolution images of the murine cardiovascular system. High-field scanners, however, require special equipment and imaging protocols. The aim of this chapter is to provide instructions on how to obtain morphological and functional data on the murine cardiovascular system in animal models of atherosclerotic disease on a very high-field scanner (17.6 T). Equipment requirements are presented, and a comprehensive description of the methods needed to complete a magnetic resonance imaging exam, including the animal preparation, imaging, and image analysis are discussed. In addition, common problems during high-field MRI experiments and methods to validate MRI results are reviewed. The steps can be adopted to other MRI scanners and modification of the imaging parameters might allow for a more individual assessment of cardiovascular diseases in a number of transgenic mouse models.
- 1 January 2008
- Published by Springer Nature
- p. 245-257
Magnetic Resonance of Mouse Models of Cardiac Disease
In recent years magnetic resonance imaging (MRI) has become the noninvasive standard for the quantitative evaluation of cardiac function, masses, and infarct size. Wall motion analysis is used to display myocardial dysfunction and microcirculatory deficits can be displayed by perfusion imaging and quantification of the myocardial regional blood volume. Magnetic resonance spectroscopy (MRS) also provides quantitative information on cardiac energetics and, in combination with MRI, insights into cardiac structure and function. The use of both techniques permits complementary data collection within the same experimental setup. Nevertheless, it should be mentioned that MR does not directly visualize genes or gene product expression but morphological or bioenergetical outcomes of gene expression instead. In conclusion, cardiac MR is a valuable tool applicable to mouse phenotyping and, also, can be applied to assess the effects of therapeutic agents. Thus, MR of mouse models of cardiac disease has great potential to substantially contribute to the understanding of the underlying pathomechanisms and can help to evaluate new therapy options.
- 1 January 2008
- Published by Springer Nature
- p. 245-257
Magnetic Resonance of Mouse Models of Cardiac Disease
In recent years magnetic resonance imaging (MRI) has become the noninvasive standard for the quantitative evaluation of cardiac function, masses, and infarct size. Wall motion analysis is used to display myocardial dysfunction and microcirculatory deficits can be displayed by perfusion imaging and quantification of the myocardial regional blood volume. Magnetic resonance spectroscopy (MRS) also provides quantitative information on cardiac energetics and, in combination with MRI, insights into cardiac structure and function. The use of both techniques permits complementary data collection within the same experimental setup. Nevertheless, it should be mentioned that MR does not directly visualize genes or gene product expression but morphological or bioenergetical outcomes of gene expression instead. In conclusion, cardiac MR is a valuable tool applicable to mouse phenotyping and, also, can be applied to assess the effects of therapeutic agents. Thus, MR of mouse models of cardiac disease has great potential to substantially contribute to the understanding of the underlying pathomechanisms and can help to evaluate new therapy options.
- Open Access
- 19 September 2003
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 18 (4) , 516-517
Reply
- 19 September 2003
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 18 (4) , 516-517
Open AccessReply
- Open Access
- 23 December 2002
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 17 (1) , 147-152
In vivo assessment of absolute perfusion in the murine skeletal muscle with spin labeling MRI
Purpose To assess absolute perfusion in the skeletal muscle of mice in vivo with spin labeling magnetic resonance imaging (MRI) under normal and stress conditions. Materials and Methods Absolute perfusion in the skeletal muscle of 27 C57BL/6 mice was assessed in vivo non‐invasively by spin labeling MRI at 7.05 T. This technique was based on the acquisition of T1 maps with global and slice‐selective spin inversion in separate acquisitions. T1 mapping was performed by inversion recovery snapshot fast low angle shot imaging. To guarantee proper spin inversion within the whole mouse, a dedicated radiofrequency (RF) coil combination was constructed. A birdcage resonator was used for transmission, while detection of the MRI signal was achieved by a surface coil. Results Basal perfusion in the hindlimbs was determined to be 94 ± 10 mL (100 g · minute)–1 (mean ± standard error of the mean [SEM], N = 27). This value is in good agreement with perfusion values determined by invasive techniques such as microspheres. A subgroup of six animals received a constant dose of 4 mg (kg · minute)–1 of the vasodilator adenosine by an intraperitoneal catheter. In this case, perfusion was significantly increased to 179 ± 56 mL (100 g · minute)–1 (mean ± SEM, N = 6, P < 0.02). Mean basal perfusion in this subgroup was 96 ± 26 mL (100 g · minute)–1. Conclusion Spin labeling MRI is a well‐suited technique for the in vivo assessment of absolute perfusion in the murine skeletal muscle. J. Magn. Reson. Imaging 2003;17:147–152.
- 23 December 2002
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 17 (1) , 147-152
Open AccessIn vivo assessment of absolute perfusion in the murine skeletal muscle with spin labeling MRI
Purpose To assess absolute perfusion in the skeletal muscle of mice in vivo with spin labeling magnetic resonance imaging (MRI) under normal and stress conditions. Materials and Methods Absolute perfusion in the skeletal muscle of 27 C57BL/6 mice was assessed in vivo non‐invasively by spin labeling MRI at 7.05 T. This technique was based on the acquisition of T1 maps with global and slice‐selective spin inversion in separate acquisitions. T1 mapping was performed by inversion recovery snapshot fast low angle shot imaging. To guarantee proper spin inversion within the whole mouse, a dedicated radiofrequency (RF) coil combination was constructed. A birdcage resonator was used for transmission, while detection of the MRI signal was achieved by a surface coil. Results Basal perfusion in the hindlimbs was determined to be 94 ± 10 mL (100 g · minute)–1 (mean ± standard error of the mean [SEM], N = 27). This value is in good agreement with perfusion values determined by invasive techniques such as microspheres. A subgroup of six animals received a constant dose of 4 mg (kg · minute)–1 of the vasodilator adenosine by an intraperitoneal catheter. In this case, perfusion was significantly increased to 179 ± 56 mL (100 g · minute)–1 (mean ± SEM, N = 6, P < 0.02). Mean basal perfusion in this subgroup was 96 ± 26 mL (100 g · minute)–1. Conclusion Spin labeling MRI is a well‐suited technique for the in vivo assessment of absolute perfusion in the murine skeletal muscle. J. Magn. Reson. Imaging 2003;17:147–152.