Jan Boese
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jan Boese has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Rebecca Fahrig
Stanford Univ. (United States)
3 shared publications - Andreas Fieselmann
Siemens AG (Germany)
2 shared publications - Joachim Hornegger
Friedrich-Alexander-Univ. Erlangen-Nürnberg (Germany)
2 shared publications - Arundhuti Ganguly
Department of Radiology, Stanford University, 1201 Welch Rd., Palo Alto, CA 94305, USA
1 shared publication Deuerling-Zheng Yu
Siemens AG (Germany)
1 shared publication- Frank Dennerlein
Siemens AG, Healthcare Sector, Forchheim 91301, Germany
1 shared publication
Latest Publications
- 26 May 2011
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (12) , 3701-3717
A model for filtered backprojection reconstruction artifacts due to time-varying attenuation values in perfusion C-arm CT
Filtered backprojection is the basis for many CT reconstruction tasks. It assumes constant attenuation values of the object during the acquisition of the projection data. Reconstruction artifacts can arise if this assumption is violated. For example, contrast flow in perfusion imaging with C-arm CT systems, which have acquisition times of several seconds per C-arm rotation, can cause this violation. In this paper, we derived and validated a novel spatio-temporal model to describe these kinds of artifacts. The model separates the temporal dynamics due to contrast flow from the scan and reconstruction parameters. We introduced derivative-weighted point spread functions to describe the spatial spread of the artifacts. The model allows prediction of reconstruction artifacts for given temporal dynamics of the attenuation values. Furthermore, it can be used to systematically investigate the influence of different reconstruction parameters on the artifacts. We have shown that with optimized redundancy weighting function parameters the spatial spread of the artifacts around a typical arterial vessel can be reduced by about 70%. Finally, an inversion of our model could be used as the basis for novel dynamic reconstruction algorithms that further minimize these artifacts.
- 26 May 2011
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (12) , 3701-3717
A model for filtered backprojection reconstruction artifacts due to time-varying attenuation values in perfusion C-arm CT
Filtered backprojection is the basis for many CT reconstruction tasks. It assumes constant attenuation values of the object during the acquisition of the projection data. Reconstruction artifacts can arise if this assumption is violated. For example, contrast flow in perfusion imaging with C-arm CT systems, which have acquisition times of several seconds per C-arm rotation, can cause this violation. In this paper, we derived and validated a novel spatio-temporal model to describe these kinds of artifacts. The model separates the temporal dynamics due to contrast flow from the scan and reconstruction parameters. We introduced derivative-weighted point spread functions to describe the spatial spread of the artifacts. The model allows prediction of reconstruction artifacts for given temporal dynamics of the attenuation values. Furthermore, it can be used to systematically investigate the influence of different reconstruction parameters on the artifacts. We have shown that with optimized redundancy weighting function parameters the spatial spread of the artifacts around a typical arterial vessel can be reduced by about 70%. Finally, an inversion of our model could be used as the basis for novel dynamic reconstruction algorithms that further minimize these artifacts.
- 3 March 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7964, 79641W
Automatic measurement of contrast bolus distribution in carotid arteries using a C-arm angiography system to support interventional perfusion imaging
Brain perfusion CT using a C-arm angiography system capable of CT-like imaging could optimize patient treatment during stroke therapy procedures. For this application, an intra-arterial contrast bolus injection at the aortic arch could be used provided that the location of the injection catheter enables uniform distribution of the bolus into the two common carotid arteries (CCA). In this work, we present a novel method to support optimal injection catheter placement by providing additional quantitative information about the distribution of the contrast bolus into the CCAs. Our fully automatic method uses 2-D digital subtraction angiography (DSA) images following a test bolus injection. It segments both CCAs and computes the relative contrast distribution. We have tested the method in DSA data sets from 5 healthy pigs and our method achieved successful segmentation of both CCAs in all data sets. The results showed that the contrast is uniformly distributed (mean relative difference less or equal than 10%) if the injection location is properly chosen.
- 3 March 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7964, 79641W
Automatic measurement of contrast bolus distribution in carotid arteries using a C-arm angiography system to support interventional perfusion imaging
Brain perfusion CT using a C-arm angiography system capable of CT-like imaging could optimize patient treatment during stroke therapy procedures. For this application, an intra-arterial contrast bolus injection at the aortic arch could be used provided that the location of the injection catheter enables uniform distribution of the bolus into the two common carotid arteries (CCA). In this work, we present a novel method to support optimal injection catheter placement by providing additional quantitative information about the distribution of the contrast bolus into the CCAs. Our fully automatic method uses 2-D digital subtraction angiography (DSA) images following a test bolus injection. It segments both CCAs and computes the relative contrast distribution. We have tested the method in DSA data sets from 5 healthy pigs and our method achieved successful segmentation of both CCAs in all data sets. The results showed that the contrast is uniformly distributed (mean relative difference less or equal than 10%) if the injection location is properly chosen.
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4 (10823654) , 2620-2628
Cardiac C-arm CT: Efficient Motion Correction for 4D-FBP
Cardiac C-arm CT is a promising technique that enables 3D cardiac image acquisition and real-time fluoroscopy on the same system. The goal is to bring 3D imaging to the interventional suite for improved therapy planning, guidance, and monitoring. For the reconstruction of 3D cardiac image data, a complete set of projections from a specific heart phase is required. One approach to reduce motion blurring caused by the beating heart is to acquire multiple sweeps using the C-arm and retrospectively select the projections that are closest to the desired cardiac phase. In order to further improve the temporal resolution, novel image processing algorithms that utilize retrospective motion correction were investigated in this study. The main focus of this work is to extend the well established FDK algorithm to incorporate motion correction during the back-projection step using a subject specific computed motion field. In a simulation study we show that motion blurring can be decreased significantly using the subjects' individual estimated heart motion based on a time series of retrospectively gated FDK reconstructions. In our experiments using an animal model we investigated the following two scenarios: (I) Can the image quality from a single sweep be improved given a subjects' individual prior computed motion field? (II) Can improved image quality be achieved using the full temporal resolution of a multi-sweep scan for motion estimation in combination with motion correction? Our results show that increasing temporal resolution using an first order estimated 4D motion vector field of the subjects' individual heart motion in the FDK-4D algorithm can decrease motion blurring substantially for both investigated scenarios.
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4 (10823654) , 2620-2628
Cardiac C-arm CT: Efficient Motion Correction for 4D-FBP
Cardiac C-arm CT is a promising technique that enables 3D cardiac image acquisition and real-time fluoroscopy on the same system. The goal is to bring 3D imaging to the interventional suite for improved therapy planning, guidance, and monitoring. For the reconstruction of 3D cardiac image data, a complete set of projections from a specific heart phase is required. One approach to reduce motion blurring caused by the beating heart is to acquire multiple sweeps using the C-arm and retrospectively select the projections that are closest to the desired cardiac phase. In order to further improve the temporal resolution, novel image processing algorithms that utilize retrospective motion correction were investigated in this study. The main focus of this work is to extend the well established FDK algorithm to incorporate motion correction during the back-projection step using a subject specific computed motion field. In a simulation study we show that motion blurring can be decreased significantly using the subjects' individual estimated heart motion based on a time series of retrospectively gated FDK reconstructions. In our experiments using an animal model we investigated the following two scenarios: (I) Can the image quality from a single sweep be improved given a subjects' individual prior computed motion field? (II) Can improved image quality be achieved using the full temporal resolution of a multi-sweep scan for motion estimation in combination with motion correction? Our results show that increasing temporal resolution using an first order estimated 4D motion vector field of the subjects' individual heart motion in the FDK-4D algorithm can decrease motion blurring substantially for both investigated scenarios.