Yves Bérubé-Lauzière
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yves Bérubé-Lauzière has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Réjean Fontaine
Université de Sherbrooke
5 shared publications - Julien Rossignol
Institution interdisciplinaire d'innovation technologique, Universite de Sherbrooke, 3000 boul de l'université, Sherbrooke, Quebec, J1K 0A5, CANADA
4 shared publications David Roy-Guay
SBQuantum
3 shared publicationsMichel Pioro-Ladrière
3 shared publicationsRomain Ruhlmann
SBQuantum
3 shared publicationsAnkita Chakravarty
Institut quantique Université de Sherbrooke J1K 2R1 Sherbrooke Québec Canada
2 shared publications
Latest Publications
- 19 February 2026
- Published by American Physical Society (APS) in Physical Review A
- Vol. 113 (2)
Leveraging analog neutral-atom quantum computers for diversified pricing in hybrid column-generation frameworks
- 19 February 2026
- Published by American Physical Society (APS) in Physical Review A
- Vol. 113 (2)
Leveraging analog neutral-atom quantum computers for diversified pricing in hybrid column-generation frameworks
- 22 January 2026
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 43 (2) , 289
Triple-tone microwave control for sensitivity optimization in compact ensemble nitrogen-vacancy magnetometers
Ensembles of nitrogen-vacancy (NV) centers in diamond are a well-established platform for quantum magnetometry under ambient conditions. One challenge arises from the hyperfine structure of the NV, which, for the common 14 N isotope, results in a threefold reduction of contrast and thus sensitivity. By addressing each of the NV hyperfine transitions individually, triple-tone microwave (MW) control can mitigate this sensitivity loss. Here, we experimentally and theoretically investigate the regimes in which triple-tone excitation offers an advantage over standard single-tone MW control for two DC magnetometry protocols: pulsed optically detected magnetic resonance (ODMR) and Ramsey interferometry. We validate a master equation model of the NV dynamics against ensemble NV measurements and use the model to explore triple-tone versus single-tone sensitivity for different MW powers and NV dephasing rates. For pulsed ODMR, triple-tone driving improves sensitivity by up to a factor of three in the low dephasing regime, with diminishing gains when dephasing rates approach the hyperfine splitting. In contrast, for Ramsey interferometry, triple-tone excitation only improves sensitivity if MW power is limited. Our results delineate the operating regimes where triple-tone control provides a practical strategy for enhancing NV ensemble magnetometry in portable and power-limited sensors.
- 22 January 2026
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 43 (2) , 289
Triple-tone microwave control for sensitivity optimization in compact ensemble nitrogen-vacancy magnetometers
Ensembles of nitrogen-vacancy (NV) centers in diamond are a well-established platform for quantum magnetometry under ambient conditions. One challenge arises from the hyperfine structure of the NV, which, for the common 14 N isotope, results in a threefold reduction of contrast and thus sensitivity. By addressing each of the NV hyperfine transitions individually, triple-tone microwave (MW) control can mitigate this sensitivity loss. Here, we experimentally and theoretically investigate the regimes in which triple-tone excitation offers an advantage over standard single-tone MW control for two DC magnetometry protocols: pulsed optically detected magnetic resonance (ODMR) and Ramsey interferometry. We validate a master equation model of the NV dynamics against ensemble NV measurements and use the model to explore triple-tone versus single-tone sensitivity for different MW powers and NV dephasing rates. For pulsed ODMR, triple-tone driving improves sensitivity by up to a factor of three in the low dephasing regime, with diminishing gains when dephasing rates approach the hyperfine splitting. In contrast, for Ramsey interferometry, triple-tone excitation only improves sensitivity if MW power is limited. Our results delineate the operating regimes where triple-tone control provides a practical strategy for enhancing NV ensemble magnetometry in portable and power-limited sensors.
- Open Access
- 3 December 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (23) , 235030
Study of dose reduction in computed tomography using a time-of-flight scatter rejection mechanism in a 3D voxelized phantom
Objective . Scattered photons are the main source of contrast degradation in x-ray imaging when not filtered out appropriately. Measuring the time-of-flight (ToF) of x-ray photons has recently been revisited as an innovative way to discriminate between primary and scattered photons without significant loss in sensitivity in order to improve the contrast-to-noise ratio (CNR) in radiography and computed tomography (CT). The technique could allow for the removal of the anti-scatter grid (ASG) while still producing a CNR comparable to that of a fan-beam CT, allowing for potential dose reduction and more uniform axial spatial resolution when used in a cone-beam configuration. Approach . This work presents an evaluation study of the potential reduction in absorbed radiation dose in the body during a CT image acquisition when using time-correlated single photon counting CT in a cone-beam geometry. A comparative study is carried out using Monte Carlo simulations in GEANT4 Application for Tomographic Emission of a voxelized body of an adult female for a multi-slice fan beam CT scanner and a cone beam system using ToF measurements with various timing jitters or ASGs. Main results . For CNR equivalent torso images, simulation data in the high contrast region for ToF of 10, 50, 100, 200 ps full width at half maximum (FWHM) timing jitters show a dose reduction of 35%, 28%, 15%, 5% respectively compared to cone-beam CT with an ASG. Compared to a fan-beam setup without an ASG, the cone-beam ToF CT achieved a dose reduction of 13% and 4% for 10 and 50 ps FWHM timing jitter respectively, and an increase of 13% and 26% at 100 and 200 ps timing jitter. In the low contrast region, 10 ps ToF led to a reduction in dose of 15% and 50 ps led to an increase of 5%. Resolutions above 100 ps failed to accurately reject scattered photons and led to a considerable increase in dose. Significance . ToF scatter rejection shows potential for reducing radiation dose while preserving image quality when the timing resolution is 50 ps FWHM or better, but better ToF-based scatter rejection algorithms are required to enable this method for worse timing resolutions and low contrast regions.
- 3 December 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (23) , 235030
Open AccessStudy of dose reduction in computed tomography using a time-of-flight scatter rejection mechanism in a 3D voxelized phantom
Objective . Scattered photons are the main source of contrast degradation in x-ray imaging when not filtered out appropriately. Measuring the time-of-flight (ToF) of x-ray photons has recently been revisited as an innovative way to discriminate between primary and scattered photons without significant loss in sensitivity in order to improve the contrast-to-noise ratio (CNR) in radiography and computed tomography (CT). The technique could allow for the removal of the anti-scatter grid (ASG) while still producing a CNR comparable to that of a fan-beam CT, allowing for potential dose reduction and more uniform axial spatial resolution when used in a cone-beam configuration. Approach . This work presents an evaluation study of the potential reduction in absorbed radiation dose in the body during a CT image acquisition when using time-correlated single photon counting CT in a cone-beam geometry. A comparative study is carried out using Monte Carlo simulations in GEANT4 Application for Tomographic Emission of a voxelized body of an adult female for a multi-slice fan beam CT scanner and a cone beam system using ToF measurements with various timing jitters or ASGs. Main results . For CNR equivalent torso images, simulation data in the high contrast region for ToF of 10, 50, 100, 200 ps full width at half maximum (FWHM) timing jitters show a dose reduction of 35%, 28%, 15%, 5% respectively compared to cone-beam CT with an ASG. Compared to a fan-beam setup without an ASG, the cone-beam ToF CT achieved a dose reduction of 13% and 4% for 10 and 50 ps FWHM timing jitter respectively, and an increase of 13% and 26% at 100 and 200 ps timing jitter. In the low contrast region, 10 ps ToF led to a reduction in dose of 15% and 50 ps led to an increase of 5%. Resolutions above 100 ps failed to accurately reject scattered photons and led to a considerable increase in dose. Significance . ToF scatter rejection shows potential for reducing radiation dose while preserving image quality when the timing resolution is 50 ps FWHM or better, but better ToF-based scatter rejection algorithms are required to enable this method for worse timing resolutions and low contrast regions.
- Open Access
- 28 October 2025
- Published by Optica Publishing Group in Optica Open
Triple-Tone Microwave Control for Sensitivity Optimization in Compact Ensemble Nitrogen-Vacancy Magnetometers
Ensembles of nitrogen-vacancy (NV) centers in diamond are a well-established platform for quantum magnetometry under ambient conditions. One challenge arises from the hyperfine structure of the NV, which, for the common $^{14}$N isotope, results in a threefold reduction of contrast and thus sensitivity. By addressing each of the NV hyperfine transitions individually, triple-tone microwave (MW) control can mitigate this sensitivity loss. Here, we experimentally and theoretically investigate the regimes in which triple-tone excitation offers an advantage over standard single-tone MW control for two DC magnetometry protocols: pulsed optically detected magnetic resonance (ODMR) and Ramsey interferometry. We validate a master equation model of the NV dynamics against ensemble NV measurements, and use the model to explore triple-tone vs single-tone sensitivity for different MW powers and NV dephasing rates. For pulsed ODMR, triple-tone driving improves sensitivity by up to a factor of three in the low-dephasing regime, with diminishing gains when dephasing rates approach the hyperfine splitting. In contrast, for Ramsey interferometry, triple-tone excitation only improves sensitivity if MW power is limited. Our results delineate the operating regimes where triple-tone control provides a practical strategy for enhancing NV ensemble magnetometry in portable and power-limited sensors.
- 28 October 2025
- Published by Optica Publishing Group in Optica Open
Open AccessTriple-Tone Microwave Control for Sensitivity Optimization in Compact Ensemble Nitrogen-Vacancy Magnetometers
Ensembles of nitrogen-vacancy (NV) centers in diamond are a well-established platform for quantum magnetometry under ambient conditions. One challenge arises from the hyperfine structure of the NV, which, for the common $^{14}$N isotope, results in a threefold reduction of contrast and thus sensitivity. By addressing each of the NV hyperfine transitions individually, triple-tone microwave (MW) control can mitigate this sensitivity loss. Here, we experimentally and theoretically investigate the regimes in which triple-tone excitation offers an advantage over standard single-tone MW control for two DC magnetometry protocols: pulsed optically detected magnetic resonance (ODMR) and Ramsey interferometry. We validate a master equation model of the NV dynamics against ensemble NV measurements, and use the model to explore triple-tone vs single-tone sensitivity for different MW powers and NV dephasing rates. For pulsed ODMR, triple-tone driving improves sensitivity by up to a factor of three in the low-dephasing regime, with diminishing gains when dephasing rates approach the hyperfine splitting. In contrast, for Ramsey interferometry, triple-tone excitation only improves sensitivity if MW power is limited. Our results delineate the operating regimes where triple-tone control provides a practical strategy for enhancing NV ensemble magnetometry in portable and power-limited sensors.
- Open Access
- 28 October 2025
- Published by Optica Publishing Group in Optica Open
Triple-Tone Microwave Control for Sensitivity Optimization in Compact Ensemble Nitrogen-Vacancy Magnetometers
Ensembles of nitrogen-vacancy (NV) centers in diamond are a well-established platform for quantum magnetometry under ambient conditions. One challenge arises from the hyperfine structure of the NV, which, for the common $^{14}$N isotope, results in a threefold reduction of contrast and thus sensitivity. By addressing each of the NV hyperfine transitions individually, triple-tone microwave (MW) control can mitigate this sensitivity loss. Here, we experimentally and theoretically investigate the regimes in which triple-tone excitation offers an advantage over standard single-tone MW control for two DC magnetometry protocols: pulsed optically detected magnetic resonance (ODMR) and Ramsey interferometry. We validate a master equation model of the NV dynamics against ensemble NV measurements, and use the model to explore triple-tone vs single-tone sensitivity for different MW powers and NV dephasing rates. For pulsed ODMR, triple-tone driving improves sensitivity by up to a factor of three in the low-dephasing regime, with diminishing gains when dephasing rates approach the hyperfine splitting. In contrast, for Ramsey interferometry, triple-tone excitation only improves sensitivity if MW power is limited. Our results delineate the operating regimes where triple-tone control provides a practical strategy for enhancing NV ensemble magnetometry in portable and power-limited sensors.
- 28 October 2025
- Published by Optica Publishing Group in Optica Open
Open AccessTriple-Tone Microwave Control for Sensitivity Optimization in Compact Ensemble Nitrogen-Vacancy Magnetometers
Ensembles of nitrogen-vacancy (NV) centers in diamond are a well-established platform for quantum magnetometry under ambient conditions. One challenge arises from the hyperfine structure of the NV, which, for the common $^{14}$N isotope, results in a threefold reduction of contrast and thus sensitivity. By addressing each of the NV hyperfine transitions individually, triple-tone microwave (MW) control can mitigate this sensitivity loss. Here, we experimentally and theoretically investigate the regimes in which triple-tone excitation offers an advantage over standard single-tone MW control for two DC magnetometry protocols: pulsed optically detected magnetic resonance (ODMR) and Ramsey interferometry. We validate a master equation model of the NV dynamics against ensemble NV measurements, and use the model to explore triple-tone vs single-tone sensitivity for different MW powers and NV dephasing rates. For pulsed ODMR, triple-tone driving improves sensitivity by up to a factor of three in the low-dephasing regime, with diminishing gains when dephasing rates approach the hyperfine splitting. In contrast, for Ramsey interferometry, triple-tone excitation only improves sensitivity if MW power is limited. Our results delineate the operating regimes where triple-tone control provides a practical strategy for enhancing NV ensemble magnetometry in portable and power-limited sensors.
- Open Access
- 29 August 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (17) , 175017
Scatter estimation and correction using time-of-flight and deconvolution in x-ray medical imaging
Objective. Time-of-flight (TOF) scatter rejection requires a total timing jitter, including the detector timing jitter and the x-ray source’s pulses width, of 50 ps or less to mitigate most of the effects of scattered photons in radiography and CT imaging. However, since the total contribution of the source and detector to the timing jitter can be retrieved during an acquisition with nothing between the source and detector, it can be demonstrated that this contribution may be partially removed to improve the image quality. Approach. A scatter correction method using iterative deconvolution of the measured time point-spread function estimates the number of scattered photons detected in each pixel. To evaluate the quality of the estimation, GATE was used to simulate the radiography of a water cylinder with bone inserts, and a head and torso in a system with total timing jitters from 100 ps up to 500 ps full-width-at-half-maximum (FWHM). Main results. With a total timing jitter of 200 ps FWHM, 89% of the contrast degradation caused by scattered photons was recovered in a head and torso radiography, compared to 28% with a simple time threshold method. Corrected images using the estimation have a percent root-mean square error between 2% and 14% in both phantoms with timing jitters from 100 to 500 ps FWHM which is lower than the error achieved with scatter rejection alone at 100 ps FWHM. Significance. TOF x-ray imaging has the potential to mitigate the effects of the scattering contribution and offers an alternative to anti-scatter grids that avoids loss of primary photons. Compare to simple TOF scatter rejection using only a threshold, the deconvolution estimation approach has lower requirements on both the source and detector. These requirements are now within reach of state-of-the-art systems.
- 29 August 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (17) , 175017
Open AccessScatter estimation and correction using time-of-flight and deconvolution in x-ray medical imaging
Objective. Time-of-flight (TOF) scatter rejection requires a total timing jitter, including the detector timing jitter and the x-ray source’s pulses width, of 50 ps or less to mitigate most of the effects of scattered photons in radiography and CT imaging. However, since the total contribution of the source and detector to the timing jitter can be retrieved during an acquisition with nothing between the source and detector, it can be demonstrated that this contribution may be partially removed to improve the image quality. Approach. A scatter correction method using iterative deconvolution of the measured time point-spread function estimates the number of scattered photons detected in each pixel. To evaluate the quality of the estimation, GATE was used to simulate the radiography of a water cylinder with bone inserts, and a head and torso in a system with total timing jitters from 100 ps up to 500 ps full-width-at-half-maximum (FWHM). Main results. With a total timing jitter of 200 ps FWHM, 89% of the contrast degradation caused by scattered photons was recovered in a head and torso radiography, compared to 28% with a simple time threshold method. Corrected images using the estimation have a percent root-mean square error between 2% and 14% in both phantoms with timing jitters from 100 to 500 ps FWHM which is lower than the error achieved with scatter rejection alone at 100 ps FWHM. Significance. TOF x-ray imaging has the potential to mitigate the effects of the scattering contribution and offers an alternative to anti-scatter grids that avoids loss of primary photons. Compare to simple TOF scatter rejection using only a threshold, the deconvolution estimation approach has lower requirements on both the source and detector. These requirements are now within reach of state-of-the-art systems.
- 20 February 2024
- Published by American Physical Society (APS) in Physical Review A
- Vol. 109 (2) , 022609
Preparation of cavity-Fock-state superpositions by reinforcement learning exploiting measurement backaction
Preparation of bosonic and general cavity quantum states usually relies on using open-loop control to reach a desired target state. In this work, a measurement-based feedback approach is used instead, exploiting the nonlinearity of weak measurements alongside a coherent drive to prepare these states. The extension of previous work on Lyapunov-based control is shown to fail for this task. This prompts for a different approach, and reinforcement learning (RL) is resorted to here for this purpose. With such an approach, cavity-eigenstate superpositions can be prepared with fidelities over using only the measurements backaction as the nonlinearity, while naturally incorporating detection of cavity photon jumps. Two different RL frameworks are analyzed: an off-policy approach recently introduced called truncated quantile critic (TQC) and the on-policy method commonly used in quantum control, namely proximal policy optimization. It is shown that TQC performs better at reaching higher target state fidelity preparation.- 20 February 2024
- Published by American Physical Society (APS) in Physical Review A
- Vol. 109 (2) , 022609
Preparation of cavity-Fock-state superpositions by reinforcement learning exploiting measurement backaction
Preparation of bosonic and general cavity quantum states usually relies on using open-loop control to reach a desired target state. In this work, a measurement-based feedback approach is used instead, exploiting the nonlinearity of weak measurements alongside a coherent drive to prepare these states. The extension of previous work on Lyapunov-based control is shown to fail for this task. This prompts for a different approach, and reinforcement learning (RL) is resorted to here for this purpose. With such an approach, cavity-eigenstate superpositions can be prepared with fidelities over using only the measurements backaction as the nonlinearity, while naturally incorporating detection of cavity photon jumps. Two different RL frameworks are analyzed: an off-policy approach recently introduced called truncated quantile critic (TQC) and the on-policy method commonly used in quantum control, namely proximal policy optimization. It is shown that TQC performs better at reaching higher target state fidelity preparation.- Open Access
- 16 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Quantum Engineering
- Vol. 4, 1-10
Optimal Control of the Operating Regime of a Single-Electron Double Quantum Dot
The double quantum dot device benefits from the advantages of both the spin and charge qubits, while offering ways to mitigate their drawbacks. Careful gate voltage modulation can grant greater spinlike or chargelike dynamics to the device, yielding long coherence times with the former and high electrical susceptibility with the latter for electrically driven spin rotations or coherent interactions with microwave photons. As this architecture is a serious contender for the realization of a versatile physical qubit, improving its control is a critical step towards building a large-scale spin-based universal quantum computer. We show that optimal control pulses generated using the GRadient Ascent Pulse Engineering (GRAPE) algorithm can yield higher-fidelity operating regime transfers than can be achieved using linear methods.
- 16 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Quantum Engineering
- Vol. 4, 1-10
Open AccessOptimal Control of the Operating Regime of a Single-Electron Double Quantum Dot
The double quantum dot device benefits from the advantages of both the spin and charge qubits, while offering ways to mitigate their drawbacks. Careful gate voltage modulation can grant greater spinlike or chargelike dynamics to the device, yielding long coherence times with the former and high electrical susceptibility with the latter for electrically driven spin rotations or coherent interactions with microwave photons. As this architecture is a serious contender for the realization of a versatile physical qubit, improving its control is a critical step towards building a large-scale spin-based universal quantum computer. We show that optimal control pulses generated using the GRadient Ascent Pulse Engineering (GRAPE) algorithm can yield higher-fidelity operating regime transfers than can be achieved using linear methods.
- Open Access
Preparation of cavity Fock state superpositions by reinforcement learning exploiting measurement back-action
Preparation of bosonic and general cavity quantum states usually relies on using open-loop control to reach a desired target state. In this work, a measurement-based feedback approach is used instead, exploiting the non-linearity of weak measurements alongside a coherent drive to prepare these states. The extension of previous work on Lyapunov-based control is shown to fail for this task. This prompts for a different approach, and reinforcement learning (RL) is resorted to here for this purpose. With such an approach, cavity eigenstate superpositions can be prepared with fidelities over 98$\%$ using only the measurements back-action as the non-linearity, while naturally incorporating detection of cavity photon jumps. Two different RL frameworks are analyzed: an off-policy approach recently introduced called truncated quantile critic~(TQC) and the on-policy method commonly used in quantum control, namely proximal policy optimization~(PPO). It is shown that TQC performs better at reaching higher target state fidelity preparation.
Open AccessPreparation of cavity Fock state superpositions by reinforcement learning exploiting measurement back-action
Preparation of bosonic and general cavity quantum states usually relies on using open-loop control to reach a desired target state. In this work, a measurement-based feedback approach is used instead, exploiting the non-linearity of weak measurements alongside a coherent drive to prepare these states. The extension of previous work on Lyapunov-based control is shown to fail for this task. This prompts for a different approach, and reinforcement learning (RL) is resorted to here for this purpose. With such an approach, cavity eigenstate superpositions can be prepared with fidelities over 98$\%$ using only the measurements back-action as the non-linearity, while naturally incorporating detection of cavity photon jumps. Two different RL frameworks are analyzed: an off-policy approach recently introduced called truncated quantile critic~(TQC) and the on-policy method commonly used in quantum control, namely proximal policy optimization~(PPO). It is shown that TQC performs better at reaching higher target state fidelity preparation.
- 12 December 2022
- Published by American Physical Society (APS) in Physical Review B
- Vol. 106 (23) , 235309
State initialization of a hot spin qubit in a double quantum dot by measurement-based quantum feedback control
A measurement-based quantum feedback protocol is developed for spin-state initialization in a gate-defined double quantum dot spin qubit coupled to a superconducting cavity. The protocol improves qubit state initialization as it is able to robustly prepare the spin in shorter time and reach a higher fidelity, which can be preset. Being able to preset the fidelity aimed at is a highly desired feature enabling qubit initialization to be more deterministic. The protocol developed herein is also effective at high temperatures, which is critical for the current efforts toward scaling up the number of qubits in quantum computers.
- 12 December 2022
- Published by American Physical Society (APS) in Physical Review B
- Vol. 106 (23) , 235309
State initialization of a hot spin qubit in a double quantum dot by measurement-based quantum feedback control
A measurement-based quantum feedback protocol is developed for spin-state initialization in a gate-defined double quantum dot spin qubit coupled to a superconducting cavity. The protocol improves qubit state initialization as it is able to robustly prepare the spin in shorter time and reach a higher fidelity, which can be preset. Being able to preset the fidelity aimed at is a highly desired feature enabling qubit initialization to be more deterministic. The protocol developed herein is also effective at high temperatures, which is critical for the current efforts toward scaling up the number of qubits in quantum computers.