Romain Froidevaux
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Romain Froidevaux has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Markus Weiger
Institute for Biomedical Engineering ETH Zurich and University of Zurich Zurich Switzerland
7 shared publications - Klaas Paul Pruessmann
Institute for Biomedical Engineering ETH Zurich and University of Zurich Zurich Switzerland
5 shared publications - Emily Louise Baadsvik
Institute for Biomedical Engineering ETH Zurich and University of Zurich Zurich Switzerland
4 shared publications Benjamin Victor Ineichen
Department of Neuroradiology, Clinical Neuroscience Center, University Hospital Zurich University of Zurich Zurich Switzerland
2 shared publicationsDavid O. Brunner
Institute for Biomedical Engineering ETH Zurich and University of Zurich Zurich Switzerland
2 shared publicationsDavid Otto Brunner
Institute for Biomedical Engineering ETH Zurich and University of Zurich Zurich Switzerland
2 shared publications
Latest Publications
- Open Access
- 3 January 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (6) , 2332-2344
Myelin bilayer mapping in the human brain in vivo
Purpose: To quantitatively map the myelin lipid‐protein bilayer in the live human brain.Methods: This goal was pursued by integrating a multi‐TE acquisition approach targeting ultrashort T2 signals with voxel‐wise fitting to a three‐component signal model. Imaging was performed at 3 T in two healthy volunteers using high‐performance RF and gradient hardware and the HYFI sequence. The design of a suitable imaging protocol faced substantial constraints concerning SNR, imaging volume, scan time, and RF power deposition. Model fitting to data acquired using the proposed protocol was made feasible through simulation‐based optimization, and filtering was used to condition noise presentation and overall depiction fidelity.Results: A multi‐TE protocol (11 TEs of 20–780 μs) for in vivo brain imaging was developed in adherence with applicable safety regulations and practical scan time limits. Data acquired using this protocol produced accurate model fitting results, validating the suitability of the protocol for this purpose. Structured, grainy texture of myelin bilayer maps was observed and determined to be a manifestation of correlated image noise resulting from the employed acquisition strategy. Map quality was significantly improved by filtering to uniformize the k‐space noise distribution and simultaneously extending the k‐space support. The final myelin bilayer maps provided selective depiction of myelin, reconciling competitive resolution (1.4 mm) with adequate SNR and benign noise texture.Conclusion: Using the proposed technique, quantitative maps of the myelin bilayer can be obtained in vivo. These maps offer unique information content with potential applications in basic research, diagnosis, disease monitoring, and drug development.
- 3 January 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (6) , 2332-2344
Open AccessMyelin bilayer mapping in the human brain in vivo
Purpose: To quantitatively map the myelin lipid‐protein bilayer in the live human brain.Methods: This goal was pursued by integrating a multi‐TE acquisition approach targeting ultrashort T2 signals with voxel‐wise fitting to a three‐component signal model. Imaging was performed at 3 T in two healthy volunteers using high‐performance RF and gradient hardware and the HYFI sequence. The design of a suitable imaging protocol faced substantial constraints concerning SNR, imaging volume, scan time, and RF power deposition. Model fitting to data acquired using the proposed protocol was made feasible through simulation‐based optimization, and filtering was used to condition noise presentation and overall depiction fidelity.Results: A multi‐TE protocol (11 TEs of 20–780 μs) for in vivo brain imaging was developed in adherence with applicable safety regulations and practical scan time limits. Data acquired using this protocol produced accurate model fitting results, validating the suitability of the protocol for this purpose. Structured, grainy texture of myelin bilayer maps was observed and determined to be a manifestation of correlated image noise resulting from the employed acquisition strategy. Map quality was significantly improved by filtering to uniformize the k‐space noise distribution and simultaneously extending the k‐space support. The final myelin bilayer maps provided selective depiction of myelin, reconciling competitive resolution (1.4 mm) with adequate SNR and benign noise texture.Conclusion: Using the proposed technique, quantitative maps of the myelin bilayer can be obtained in vivo. These maps offer unique information content with potential applications in basic research, diagnosis, disease monitoring, and drug development.
- Open Access
- 17 October 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (2) , 665-677
Mapping the myelin bilayer with short‐T2 MRI: Methods validation and reference data for healthy human brain
Purpose: To explore the properties of short‐T2 signals in human brain, investigate the impact of various experimental procedures on these properties and evaluate the performance of three‐component analysis.Methods: Eight samples of non‐pathological human brain tissue were subjected to different combinations of experimental procedures including D2O exchange and frozen storage. Short‐T2 imaging techniques were employed to acquire multi‐TE (33–2067 μs) data, to which a three‐component complex model was fitted in two steps to recover the properties of the underlying signal components and produce amplitude maps of each component. For validation of the component amplitude maps, the samples underwent immunohistochemical myelin staining.Results: The signal component representing the myelin bilayer exhibited super‐exponential decay with T2,min of 5.48 μs and a chemical shift of 1.07 ppm, and its amplitude could be successfully mapped in both white and gray matter in all samples. These myelin maps corresponded well to myelin‐stained tissue sections. Gray matter signals exhibited somewhat different components than white matter signals, but both tissue types were well represented by the signal model. Frozen tissue storage did not alter the signal components but influenced component amplitudes. D2O exchange was necessary to characterize the non‐aqueous signal components, but component amplitude mapping could be reliably performed also in the presence of H2O signals.Conclusions: The myelin mapping approach explored here produced reasonable and stable results for all samples. The extensive tissue and methodological investigations performed in this work form a basis for signal interpretation in future studies both ex vivo and in vivo.
- 17 October 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (2) , 665-677
Open AccessMapping the myelin bilayer with short‐T2 MRI: Methods validation and reference data for healthy human brain
Purpose: To explore the properties of short‐T2 signals in human brain, investigate the impact of various experimental procedures on these properties and evaluate the performance of three‐component analysis.Methods: Eight samples of non‐pathological human brain tissue were subjected to different combinations of experimental procedures including D2O exchange and frozen storage. Short‐T2 imaging techniques were employed to acquire multi‐TE (33–2067 μs) data, to which a three‐component complex model was fitted in two steps to recover the properties of the underlying signal components and produce amplitude maps of each component. For validation of the component amplitude maps, the samples underwent immunohistochemical myelin staining.Results: The signal component representing the myelin bilayer exhibited super‐exponential decay with T2,min of 5.48 μs and a chemical shift of 1.07 ppm, and its amplitude could be successfully mapped in both white and gray matter in all samples. These myelin maps corresponded well to myelin‐stained tissue sections. Gray matter signals exhibited somewhat different components than white matter signals, but both tissue types were well represented by the signal model. Frozen tissue storage did not alter the signal components but influenced component amplitudes. D2O exchange was necessary to characterize the non‐aqueous signal components, but component amplitude mapping could be reliably performed also in the presence of H2O signals.Conclusions: The myelin mapping approach explored here produced reasonable and stable results for all samples. The extensive tissue and methodological investigations performed in this work form a basis for signal interpretation in future studies both ex vivo and in vivo.
- Open Access
- 14 November 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 87 (3) , 1360-1374
Pulse encoding for ZTE imaging: RF excitation without dead‐time penalty
Purpose To overcome limitations in the duration of RF excitation in zero-TE (ZTE) MRI by exploiting intrinsic encoding properties of RF pulses to retrieve data missed during the dead time caused by the pulse. Methods An enhanced ZTE signal model was developed using multiple RF pulses, which enables accessing information hidden in the pulse-induced dead time via encoding intrinsically applied by the RF pulses. Such ZTE with pulse encoding was implemented by acquisition of two ZTE data sets using excitation with similar frequency-swept pulses differing only by a small off-resonance in their center frequency. In this way, the minimum scan time is doubled but each acquisition contributes equally to the SNR, as with ordinary averaging. The method was demonstrated on long-T2 and short-T2 phantoms as well as in in vivo experiments. Results ZTE with pulse encoding provided good image quality at unprecedented dead-time gaps, demonstrated here up to 6 Nyquist dwells. In head imaging, the ability to use longer excitation pulses led to approximately 2-fold improvements in SNR efficiency as compared with conventional ZTE and allowed the creation of T1 contrast. Conclusion Exploiting intrinsic encoding properties of RF pulses in a new signal model enables algebraic reconstruction of ZTE data sets with large dead-time gaps. This permits larger flip angles, which can be used to achieve enhanced T1 contrast and significant improvements in SNR efficiency in case the Ernst angle can be better approached, thus broadening the range of application of ZTE MRI.
- 14 November 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 87 (3) , 1360-1374
Open AccessPulse encoding for ZTE imaging: RF excitation without dead‐time penalty
Purpose To overcome limitations in the duration of RF excitation in zero-TE (ZTE) MRI by exploiting intrinsic encoding properties of RF pulses to retrieve data missed during the dead time caused by the pulse. Methods An enhanced ZTE signal model was developed using multiple RF pulses, which enables accessing information hidden in the pulse-induced dead time via encoding intrinsically applied by the RF pulses. Such ZTE with pulse encoding was implemented by acquisition of two ZTE data sets using excitation with similar frequency-swept pulses differing only by a small off-resonance in their center frequency. In this way, the minimum scan time is doubled but each acquisition contributes equally to the SNR, as with ordinary averaging. The method was demonstrated on long-T2 and short-T2 phantoms as well as in in vivo experiments. Results ZTE with pulse encoding provided good image quality at unprecedented dead-time gaps, demonstrated here up to 6 Nyquist dwells. In head imaging, the ability to use longer excitation pulses led to approximately 2-fold improvements in SNR efficiency as compared with conventional ZTE and allowed the creation of T1 contrast. Conclusion Exploiting intrinsic encoding properties of RF pulses in a new signal model enables algebraic reconstruction of ZTE data sets with large dead-time gaps. This permits larger flip angles, which can be used to achieve enhanced T1 contrast and significant improvements in SNR efficiency in case the Ernst angle can be better approached, thus broadening the range of application of ZTE MRI.
- Open Access
- 23 February 2021
- Published by Wiley in NMR in Biomedicine
- Vol. 34 (6) , e4493
HYFI: Hybrid filling of the dead‐time gap for faster zero echo time imaging
The aim of this work was to improve the SNR efficiency of zero echo time (ZTE) MRI pulse sequences for faster imaging of short‐T2 components at large dead‐time gaps. ZTE MRI with hybrid filling (HYFI) is a strategy for retrieving inner k‐space data missed during the dead‐time gaps arising from radio‐frequency excitation and switching in ZTE imaging. It performs hybrid filling of the inner k‐space with a small single‐point‐imaging core surrounded by a stack of shells acquired on radial readouts in an onion‐like fashion. The exposition of this concept is followed by translation into guidelines for parameter choice and implementation details. The imaging properties and performance of HYFI are studied in simulations as well as phantom, in vitro and in vivo imaging, with an emphasis on comparison with the pointwise encoding time reduction with radial acquisition (PETRA) technique. Simulations predict higher SNR efficiency for HYFI compared with PETRA at preserved image quality, with the advantage increasing with the size of the k‐space gap. These results are confirmed by imaging experiments with gap sizes of 25 to 50 Nyquist dwells, in which scan times for similar image quality could be reduced by 25% to 60%. The HYFI technique provides both high SNR efficiency and image quality, thus outperforming previously known ZTE‐based pulse sequences, in particular for large k‐space gaps. Promising applications include direct imaging of ultrashort‐T2 components, such as the myelin bilayer or collagen, T2 mapping of ultrafast relaxing signals, and ZTE imaging with reduced chemical shift artifacts.
- 23 February 2021
- Published by Wiley in NMR in Biomedicine
- Vol. 34 (6) , e4493
Open AccessHYFI: Hybrid filling of the dead‐time gap for faster zero echo time imaging
The aim of this work was to improve the SNR efficiency of zero echo time (ZTE) MRI pulse sequences for faster imaging of short‐T2 components at large dead‐time gaps. ZTE MRI with hybrid filling (HYFI) is a strategy for retrieving inner k‐space data missed during the dead‐time gaps arising from radio‐frequency excitation and switching in ZTE imaging. It performs hybrid filling of the inner k‐space with a small single‐point‐imaging core surrounded by a stack of shells acquired on radial readouts in an onion‐like fashion. The exposition of this concept is followed by translation into guidelines for parameter choice and implementation details. The imaging properties and performance of HYFI are studied in simulations as well as phantom, in vitro and in vivo imaging, with an emphasis on comparison with the pointwise encoding time reduction with radial acquisition (PETRA) technique. Simulations predict higher SNR efficiency for HYFI compared with PETRA at preserved image quality, with the advantage increasing with the size of the k‐space gap. These results are confirmed by imaging experiments with gap sizes of 25 to 50 Nyquist dwells, in which scan times for similar image quality could be reduced by 25% to 60%. The HYFI technique provides both high SNR efficiency and image quality, thus outperforming previously known ZTE‐based pulse sequences, in particular for large k‐space gaps. Promising applications include direct imaging of ultrashort‐T2 components, such as the myelin bilayer or collagen, T2 mapping of ultrafast relaxing signals, and ZTE imaging with reduced chemical shift artifacts.
- 3 October 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 85 (3) , 1481-1492
High‐resolution MRI of mummified tissues using advanced short‐T2 methodology and hardware
Purpose: Evolutionary medicine aims to study disease development from a long‐term perspective, and through the analysis of mummified tissue, timescales of several thousand years are unlocked. Due to the status of mummies as ancient relics, noninvasive techniques are preferable, and, currently, CT imaging is the most widespread method. However, CT images lack soft‐tissue contrast, making complementary MRI data desirable. Unfortunately, the dehydrated nature and short T2 times of mummified tissues render them practically invisible to standard MRI techniques. Specialized short‐T2 approaches have therefore been used, but currently suffer severe resolution limitations. The purpose of the present study is to improve resolution in MRI of mummified tissues.Methods: The zero‐TE‐based hybrid filling technique, together with a high‐performance magnetic field gradient, was used to image three ancient Egyptian mummified human body parts: a hand, a foot, and a head. A similar pairing has already been shown to increase resolution and image quality in MRI of short‐T2 tissues.Results: MRI images of yet unparalleled image quality were obtained for all samples, reaching isotropic resolutions of 0.6 mm and SNR values above 100. The same general features as present in CT images were depicted but with different contrast, particularly for regions containing embalming substances.Conclusion: Mummy MRI is a potentially valuable tool for (paleo)pathological studies, as well as for investigations into ancient mummification processes. The results presented here show sufficient improvement in the depiction of mummified tissues to clear new paths for the exploration of this field.
- 3 October 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 85 (3) , 1481-1492
High‐resolution MRI of mummified tissues using advanced short‐T2 methodology and hardware
Purpose: Evolutionary medicine aims to study disease development from a long‐term perspective, and through the analysis of mummified tissue, timescales of several thousand years are unlocked. Due to the status of mummies as ancient relics, noninvasive techniques are preferable, and, currently, CT imaging is the most widespread method. However, CT images lack soft‐tissue contrast, making complementary MRI data desirable. Unfortunately, the dehydrated nature and short T2 times of mummified tissues render them practically invisible to standard MRI techniques. Specialized short‐T2 approaches have therefore been used, but currently suffer severe resolution limitations. The purpose of the present study is to improve resolution in MRI of mummified tissues.Methods: The zero‐TE‐based hybrid filling technique, together with a high‐performance magnetic field gradient, was used to image three ancient Egyptian mummified human body parts: a hand, a foot, and a head. A similar pairing has already been shown to increase resolution and image quality in MRI of short‐T2 tissues.Results: MRI images of yet unparalleled image quality were obtained for all samples, reaching isotropic resolutions of 0.6 mm and SNR values above 100. The same general features as present in CT images were depicted but with different contrast, particularly for regions containing embalming substances.Conclusion: Mummy MRI is a potentially valuable tool for (paleo)pathological studies, as well as for investigations into ancient mummification processes. The results presented here show sufficient improvement in the depiction of mummified tissues to clear new paths for the exploration of this field.
- Open Access
- 1 August 2020
- Published by Elsevier in NeuroImage
- Vol. 217, 116888
Advances in MRI of the myelin bilayer
- 1 August 2020
- Published by Elsevier in NeuroImage
- Vol. 217, 116888
Open AccessAdvances in MRI of the myelin bilayer
- Open Access
HYFI: Hybrid filling of the dead-time gap for faster zero echo time imaging
Purpose: To improve the SNR efficiency of zero echo time (ZTE) MRI pulse sequences for faster imaging of short- T 2 components at large dead-time gaps. Methods: HYFI is s strategy of retrieving inner k-space data missed during the dead-time gap arising from radio-frequency excitation and switching in ZTE imaging. It performs hybrid filling of the inner k-space with a small single-point-imaging core surrounded by a stack of shells acquired on radial readouts in an onion-like fashion. The exposition of this concept is followed by translation into guidelines for parameter choice and implementation details. The imaging properties and performance of HYFI are studied in simulations as well as phantom, in-vitro and in-vivo imaging, with an emphasis on comparison with the PETRA technique (pointwise encoding time reduction with radial acquisition). Results: Simulations predict higher SNR efficiency of HYFI compared to PETRA at preserved image quality with the advantage increasing with the size of the k-space gap. These results are confirmed by imaging experiments with gap sizes of 25 to 50 Nyquist dwells, in which scan times for similar SNR could be reduced by 25 to 60%. Conclusion: The HYFI technique provides both high SNR efficiency and image quality, thus outperforming previously known ZTE-based pulse sequences in particular for large k-space gaps. Promising applications include direct imaging of ultra-short T 2 components, such as the myelin bilayer or collagen, T 2 mapping of ultra-fast relaxing signals, and ZTE imaging with reduced chemical shift artifacts.
Open AccessHYFI: Hybrid filling of the dead-time gap for faster zero echo time imaging
Purpose: To improve the SNR efficiency of zero echo time (ZTE) MRI pulse sequences for faster imaging of short- T 2 components at large dead-time gaps. Methods: HYFI is s strategy of retrieving inner k-space data missed during the dead-time gap arising from radio-frequency excitation and switching in ZTE imaging. It performs hybrid filling of the inner k-space with a small single-point-imaging core surrounded by a stack of shells acquired on radial readouts in an onion-like fashion. The exposition of this concept is followed by translation into guidelines for parameter choice and implementation details. The imaging properties and performance of HYFI are studied in simulations as well as phantom, in-vitro and in-vivo imaging, with an emphasis on comparison with the PETRA technique (pointwise encoding time reduction with radial acquisition). Results: Simulations predict higher SNR efficiency of HYFI compared to PETRA at preserved image quality with the advantage increasing with the size of the k-space gap. These results are confirmed by imaging experiments with gap sizes of 25 to 50 Nyquist dwells, in which scan times for similar SNR could be reduced by 25 to 60%. Conclusion: The HYFI technique provides both high SNR efficiency and image quality, thus outperforming previously known ZTE-based pulse sequences in particular for large k-space gaps. Promising applications include direct imaging of ultra-short T 2 components, such as the myelin bilayer or collagen, T 2 mapping of ultra-fast relaxing signals, and ZTE imaging with reduced chemical shift artifacts.
- 16 March 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (4) , 1933-1946
High‐resolution short‐T2 MRI using a high‐performance gradient
Purpose: To achieve high resolution in imaging of short‐T2 materials and tissues by using a high‐performance human‐sized gradient insert with strength up to 200 mT/m and 100% duty cycle.Methods: Dedicated short‐T2 methodology and hardware are used, such as the pointwise encoding time reduction with radial acquisition (PETRA) technique with modulated excitation pulses, optimized radio‐frequency hardware, and a high‐performance gradient insert. A theoretical analysis of actual spatial resolution and SNR is provided to support the choice of scan parameters and interpretation of the results. Imaging is performed in resolution phantoms, animal specimen, and human volunteers at both conventional and maximum available gradient strengths and compared using image subtraction.Results: Calculations suggest that increasing gradient strength beyond conventional values considerably improves both actual resolution and SNR efficiency in short‐T2 imaging. Resolution improvements are confirmed in all investigated samples, in particular 2 mm slots were resolved in a hard‐plastic plate with T2 ≈ 10 μs and in vivo musculoskeletal images were acquired at isotropic 200 μm resolution. Expected improvements in signal yield are realized in fine structures benefitting from high resolution but to less extent in regions of low contrast where decay‐related blurring leads to signal overlap between neighboring locations.Conclusion: Strong gradients with high duty cycle enable short‐T2 imaging at unprecedentedly high resolution, holding the potential for improving MRI of, eg, bone, tendon, lung, or teeth. Moreover, it allows direct access of tissues with T2 of tens of microseconds such as myelin or collagen.
- 16 March 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (4) , 1933-1946
High‐resolution short‐T2 MRI using a high‐performance gradient
Purpose: To achieve high resolution in imaging of short‐T2 materials and tissues by using a high‐performance human‐sized gradient insert with strength up to 200 mT/m and 100% duty cycle.Methods: Dedicated short‐T2 methodology and hardware are used, such as the pointwise encoding time reduction with radial acquisition (PETRA) technique with modulated excitation pulses, optimized radio‐frequency hardware, and a high‐performance gradient insert. A theoretical analysis of actual spatial resolution and SNR is provided to support the choice of scan parameters and interpretation of the results. Imaging is performed in resolution phantoms, animal specimen, and human volunteers at both conventional and maximum available gradient strengths and compared using image subtraction.Results: Calculations suggest that increasing gradient strength beyond conventional values considerably improves both actual resolution and SNR efficiency in short‐T2 imaging. Resolution improvements are confirmed in all investigated samples, in particular 2 mm slots were resolved in a hard‐plastic plate with T2 ≈ 10 μs and in vivo musculoskeletal images were acquired at isotropic 200 μm resolution. Expected improvements in signal yield are realized in fine structures benefitting from high resolution but to less extent in regions of low contrast where decay‐related blurring leads to signal overlap between neighboring locations.Conclusion: Strong gradients with high duty cycle enable short‐T2 imaging at unprecedentedly high resolution, holding the potential for improving MRI of, eg, bone, tendon, lung, or teeth. Moreover, it allows direct access of tissues with T2 of tens of microseconds such as myelin or collagen.