Anna Kokkonen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Anna Kokkonen has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Arto Säämänen
Finnish Institute of Occupational Health, Työterveyslaitos, Finland
1 shared publication Kari Salmi
Occupational Health Institute, Helsinki, Finland
1 shared publicationMarkku Linnainmaa
Finnish Institute of Occupational Health , PO Box 486, Tampere FI-33101 , Finland
1 shared publication- Marko Hyttinen
Department of Environmental and Biological Sciences, University of Eastern Finland, 70210 Kuopio, Finland
1 shared publication Mikko Kolehmainen
Department of Environmental and Biological Sciences, University of Eastern Finland , PO Box 1627, Kuopio FI-70211 , Finland
1 shared publicationPertti Pasanen
Department of Environmental and Biological Sciences, University of Eastern Finland , PO Box 1627, Kuopio FI-70211 , Finland
1 shared publication
Latest Publications
- 30 May 2017
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 61 (6) , 681-691
Evaluation of Real-World Implementation of Partitioning and Negative Pressurization for Preventing the Dispersion of Dust From Renovation Sites
Objectives:The aim of this study was to assess the implementation of partitioning and the negative pressure method in limiting the dispersion of dust to areas adjacent to renovation sites.Methods:The pressure difference between the worksites and adjacent areas and PM10 concentrations in the both zones were measured in 12 renovation sites, and the factors affecting the prevention of dispersion of dust were assessed.Results:Poor implementation of partitioning and negative pressurization found in half of the renovation sites lead difficulties in achieving a proper negative pressure, causing dispersion of dust into adjacent areas. Main problems related to flimsy partitioning walls and poor air tightness of the enclosure. Dust concentrations in adjacent areas were substantially lower when natural ventilation in the renovation site was rejected and partitioning walls and their junctions to existing structures were sealed. In case of leaky enclosures, despite the high air exchange rates, a definite negative pressure could not be maintained. Instead, negative pressure minimum of −5 Pa was found to be sufficient for limiting the dispersion of dust from renovation sites.Conclusions:Improvement on implementation of dust controls is required through revising the guidance documents, education, and efficient supervision. This study revealed that the current Finnish practice to implement the negative pressurization based on the air exchange rate achieved with the portable exhaust fans alone is not reasonable to assure adequate dust containment. Continuous negative pressure minimum of −5 Pa is suggested, and it should be monitored with alarm devices throughout the renovation processes.
- 30 May 2017
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 61 (6) , 681-691
Evaluation of Real-World Implementation of Partitioning and Negative Pressurization for Preventing the Dispersion of Dust From Renovation Sites
Objectives:The aim of this study was to assess the implementation of partitioning and the negative pressure method in limiting the dispersion of dust to areas adjacent to renovation sites.Methods:The pressure difference between the worksites and adjacent areas and PM10 concentrations in the both zones were measured in 12 renovation sites, and the factors affecting the prevention of dispersion of dust were assessed.Results:Poor implementation of partitioning and negative pressurization found in half of the renovation sites lead difficulties in achieving a proper negative pressure, causing dispersion of dust into adjacent areas. Main problems related to flimsy partitioning walls and poor air tightness of the enclosure. Dust concentrations in adjacent areas were substantially lower when natural ventilation in the renovation site was rejected and partitioning walls and their junctions to existing structures were sealed. In case of leaky enclosures, despite the high air exchange rates, a definite negative pressure could not be maintained. Instead, negative pressure minimum of −5 Pa was found to be sufficient for limiting the dispersion of dust from renovation sites.Conclusions:Improvement on implementation of dust controls is required through revising the guidance documents, education, and efficient supervision. This study revealed that the current Finnish practice to implement the negative pressurization based on the air exchange rate achieved with the portable exhaust fans alone is not reasonable to assure adequate dust containment. Continuous negative pressure minimum of −5 Pa is suggested, and it should be monitored with alarm devices throughout the renovation processes.
- 2 August 2013
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 23 (7) , 994-1001
Performance testing of engineering controls of airborne infection isolation rooms by tracer gas techniques
The ventilation performance of airborne infection isolation rooms (AIIRs) was assessed in three Finnish hospitals by examining the air change rate, contaminant removal efficiency and leakage of contaminants outside the isolation room by using tracer gas techniques. Results showed that infectious agents can escape from the AIIR during egress despite high ventilation rates in the AIIR and anteroom (air change rate, 4–24 h−1) and the pressure difference between the AIIR and corridor was −0.2 to −29 Pa. The control of impurities was often ineffective due to inappropriate direction of air flows and air moving from the patient towards the health care worker and anteroom. Although an anteroom reduces leakage of infectious agents to the corridor significantly, it does not prevent this completely when healthcare workers move between the AIIR and corridor. To enhance the protection of AIIRs, it is especially important to pay attention to the air distribution and removal efficiency of impurities in AIIRs and anterooms. Performance of AIIRs should be tested regularly, especially among older AIIRs.
- 2 August 2013
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 23 (7) , 994-1001
Performance testing of engineering controls of airborne infection isolation rooms by tracer gas techniques
The ventilation performance of airborne infection isolation rooms (AIIRs) was assessed in three Finnish hospitals by examining the air change rate, contaminant removal efficiency and leakage of contaminants outside the isolation room by using tracer gas techniques. Results showed that infectious agents can escape from the AIIR during egress despite high ventilation rates in the AIIR and anteroom (air change rate, 4–24 h−1) and the pressure difference between the AIIR and corridor was −0.2 to −29 Pa. The control of impurities was often ineffective due to inappropriate direction of air flows and air moving from the patient towards the health care worker and anteroom. Although an anteroom reduces leakage of infectious agents to the corridor significantly, it does not prevent this completely when healthcare workers move between the AIIR and corridor. To enhance the protection of AIIRs, it is especially important to pay attention to the air distribution and removal efficiency of impurities in AIIRs and anterooms. Performance of AIIRs should be tested regularly, especially among older AIIRs.