Mübin Ulusoy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mübin Ulusoy has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Suna Toksavul
Department of Prosthetic Dentistry, Faculty of Dentistry, Ege University, Bornova-Izmir, Turkey
3 shared publications - Muhittin Toman
Department of Prosthetic Dentistry, Faculty of Dentistry, Ege University, İzmir, Turkey
1 shared publication Murat Türkün
1 shared publication- Ovul Kumbuloglu
Professor, Department of Prosthodontics, Faculty of Dentistry, Ege University, Izmir, Turkey
1 shared publication Suna Toksavul
1 shared publication
Latest Publications
- 1 March 2004
- Vol. 35 (3) , 185-8
Clinical application of all-ceramic fixed partial dentures and crowns.
The esthetic demands of patients have increased considerably during recent years. Due to this increasing interest in esthetics, as well as concerns about toxic and allergic reactions, the use of all-ceramic restorations has increased. One of the systems introduced for all-ceramic restorations is the IPS Empress system. This article examines one all-ceramic restoration system, IPS Empress, and presents patient cases in which all-ceramic crowns and fixed partial dentures have been utilized.
- 1 March 2004
- Vol. 35 (3) , 185-8
Clinical application of all-ceramic fixed partial dentures and crowns.
The esthetic demands of patients have increased considerably during recent years. Due to this increasing interest in esthetics, as well as concerns about toxic and allergic reactions, the use of all-ceramic restorations has increased. One of the systems introduced for all-ceramic restorations is the IPS Empress system. This article examines one all-ceramic restoration system, IPS Empress, and presents patient cases in which all-ceramic crowns and fixed partial dentures have been utilized.
- 1 January 2004
- Vol. 35 (1) , 11-4
Amelogenesis imperfecta: the multidisciplinary approach. A case report.
Amelogenesis imperfecta is a hereditary developmental disorder of the dental enamel, in both primary and permanent dentition. The main clinical characteristics are extensive loss of tooth tissue, poor esthetics, and tooth sensitivity. Transmission of the gene takes place by either autosomal, dominant X-linked, or recessive modes. This clinical report describes a treatment sequence based on a multidisciplinary approach. A 21-year-old girl with hypoplastic amelogenesis imperfecta was referred to the Ege University School of Dentistry clinic. She was concerned about the poor appearance and sensitivity of her teeth. The patient presented with an anterior open bite, although orthodontic treatment had been completed previously. Periodontal gingivectomy of her posterior teeth followed by endodontic treatment where indicated was proposed. The prosthodontic treatment consisted of metal ceramic fixed partial dentures of precious alloy. At the end of treatment, function and esthetics were improved to a level acceptable to both the patient and the dental team.
- 1 January 2004
- Vol. 35 (1) , 11-4
Amelogenesis imperfecta: the multidisciplinary approach. A case report.
Amelogenesis imperfecta is a hereditary developmental disorder of the dental enamel, in both primary and permanent dentition. The main clinical characteristics are extensive loss of tooth tissue, poor esthetics, and tooth sensitivity. Transmission of the gene takes place by either autosomal, dominant X-linked, or recessive modes. This clinical report describes a treatment sequence based on a multidisciplinary approach. A 21-year-old girl with hypoplastic amelogenesis imperfecta was referred to the Ege University School of Dentistry clinic. She was concerned about the poor appearance and sensitivity of her teeth. The patient presented with an anterior open bite, although orthodontic treatment had been completed previously. Periodontal gingivectomy of her posterior teeth followed by endodontic treatment where indicated was proposed. The prosthodontic treatment consisted of metal ceramic fixed partial dentures of precious alloy. At the end of treatment, function and esthetics were improved to a level acceptable to both the patient and the dental team.
- 1 February 2003
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 89 (2) , 223-224
Preventing aspiration or ingestion of fixed restorations
- 1 February 2003
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 89 (2) , 223-224
Preventing aspiration or ingestion of fixed restorations
- 12 December 2002
- Vol. 15 (6) , 571-4
Fracture resistance of five different metal framework designs for metal-ceramic restorations.
This study evaluated fracture resistance of five different metal framework designs for metal-ceramic restorations. Twenty-five artificial crowns were fabricated with different degrees of facial metal reduction: metal collar (group 1), and 0, 0.5, 1, and 1.5 mm (groups 2 to 5, respectively). All of the crowns were thermocycled in two different baths of 5 and 60 degrees C for 20 seconds and had a dwell time of 10 seconds in a resting bath at 37 degrees C for 510 cycles. The artificial crowns were then subjected to vertical loading until fracture with a Shimadzu testing machine at a cross-head speed of 1 mm/min. The load at fracture was recorded. There were no statistically significant differences between mean fracture strength of groups 1 and 2 or between groups 4 and 5. There were significant differences between group 3 and groups 1, 2, 4, and 5. As the amount of metal reduction increased, the vertical fracture resistance decreased. Failure loads for all test groups exceeded normal biting forces.
- 12 December 2002
- Vol. 15 (6) , 571-4
Fracture resistance of five different metal framework designs for metal-ceramic restorations.
This study evaluated fracture resistance of five different metal framework designs for metal-ceramic restorations. Twenty-five artificial crowns were fabricated with different degrees of facial metal reduction: metal collar (group 1), and 0, 0.5, 1, and 1.5 mm (groups 2 to 5, respectively). All of the crowns were thermocycled in two different baths of 5 and 60 degrees C for 20 seconds and had a dwell time of 10 seconds in a resting bath at 37 degrees C for 510 cycles. The artificial crowns were then subjected to vertical loading until fracture with a Shimadzu testing machine at a cross-head speed of 1 mm/min. The load at fracture was recorded. There were no statistically significant differences between mean fracture strength of groups 1 and 2 or between groups 4 and 5. There were significant differences between group 3 and groups 1, 2, 4, and 5. As the amount of metal reduction increased, the vertical fracture resistance decreased. Failure loads for all test groups exceeded normal biting forces.