KKKhaled Al Khalifah

Khaled Al Khalifah

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Khaled Al Khalifah has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Using aluminum for scatter control in mammography: preliminary work using measurements of CNR and FOM

    by Khaled Al Khalifah, Rob Davidson, Abel Zhou

    Full-field digital mammography (FFDM) systems provide the current gold standard in mammographic examinations. Although FFDM provides the lowest mammographic doses, the radiation dose to the breast during mammographic examinations is still a concern. Thus, image quality optimization at the lowest dose is a major goal. In planar X-ray imaging, thin sheets of aluminum (Al) are used as filtration to reduce the number of low-energy X-ray photons reaching the patient. The goal of this work was to evaluate whether Al can be used in FFDM to remove scatter radiation from reaching the image detector, hence improving image quality. Doses were compared with the use of a grid. A Hologic Selenia mammographic unit was used to acquire images of two phantoms, namely, the ACR phantom and a Perspex phantom of 5 cm. Images were acquired using two tube voltages (kVp) and filter combinations under two exposure/dose conditions. Al sheets of various thicknesses were placed between the phantom and the image detector. Contrast-to-noise ratio (CNR) and figure of merit (FOM) values were measured and compared with images acquired using a grid. When a constant dose was delivered to the image detector, the highest CNR was achieved using a grid; however, the highest FOM values were achieved when using 0.05 mm thick Al sheets. This study successfully demonstrates that thin sheets of Al can be used in mammography examinations to reduce scattered radiation and improve image quality, as indicated by the measured CNR values. Given the limitations of this work, further kVp and target/filter combinations and various methods of image quality measurement need to be studied.


    • 1 January 2019
      • Vol. 48  (1) , e15-e19

    Validity of Using Accreditation Phantom in Quality Control of Digital Tomosynthesis.

    by Khaled Al Khalifah, Ajit Brindabhan, Maya Mathew, Rob Davidson

    This study was undertaken to compare the two image-quality phantoms commonly used in full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT) imaging. Mammography units with two targets and three filters resulting in three possible target/filter combinations and two kVp values which are widely used (28 and 32) were used for the comparison. The automatic exposure control system was used in combination with the selected kVp. The CIRS 15 mammographic accreditation phantom (MAP) and CIRS 20 (BR3D) breast imaging phantom were used with the three target/filter combinations and two kVp values. A total of 24 images were acquired and evaluated. Image score was determined as the smallest sized object detectable. The data were analyzed by using Mann-Whitney test. There were significant (p<0.001) differences between the detectability of fibers present in the two phantoms, but there were no differences in the detectability of specks. The finding in FFDM and DBT showed there were significant differences between the two phantoms (p<0.02) in fibers and specks visibility. The CIRS 20 phantom provided greater visibility of smaller structures, while the MAP was more suitable for assessing image quality of both FFDM and DBT imaging systems.

  • Open Access

    Investigation of Exposure Factors for Various Breast Composition and Thicknesses in Digital Screening Mammography Related to Breast Dose

    by Khaled Alkhalifah, Ajit Brindhaban

    Objective: To investigate the effect of exposure factors used in digital screening mammography on image quality of different breast compositions. Material and Methods: A digital mammography unit, with tungsten (W) as target, rhodium (Rh) and silver (Ag) as filters, and amorphous selenium detectors, was used to image Computerized Imaging Reference Systems (CIRS) Model 12A phantoms of thickness 4, 5, and 6 cm. Images of each phantom were obtained using target-filter combinations of W/Rh and W/Ag, at 28, 30, and 32 kVp. Images were evaluated by 5 senior technologists with experience in mammography. Image scores were assigned, for each type of feature present in the phantom. Statistical analysis was performed using nonparametric tests to compare sets of image scores at p = 0.05. Results: A small but statistically significant improvement was detected in the visibility of microcalcifications (8.8 ± 0.2; p = 0.031) for the W/Rh combination but this did not show any differences in the visibility of masses or fibers. The entrance skin dose (ESD) and mean glandular dose (MGD) were lower for the W/Ag (ESD = 1.30–3.70; MGD = 0.44–0.93 mGy) combination compared to W/Rh (ESD = 1.66–5.40; MGD = 0.52–1.12 mGy). The Mann-Whitney test revealed that 30-kV exposure with the W/Rh combination showed a significantly better visibility of specks in the 30/70 phantom compared to other exposures. Conclusion: The use of an Rh filter showed a better image quality for all phantoms. 28 and 30 kVp with the W/Rh combination provided a slightly better image quality, and the MGD is less than 1.2 mGy.


  • Effect of exposure factors on image quality in screening mammography

    by K. Alkhalifah, A. Brindabhan, R. Alsaeed


    • 1 January 2017
      • Vol. 46  (4) , 239-242

    Mammographic Phantoms Frequently Used to Determine Image Quality: A Comparative Study.

    by Khaled Alkhalifah, Ajit Brindhaban

    Appropriate diagnosis depends on the image quality of the mammographic system. Phantoms are normally used, since they have physical properties similar to those of different human tissues, and are important tools for quality assurance of mammography equipment, evaluation of image quality, and accurate determination of patient dosage. The aim of this study was to evaluate various mammographic phantoms used to determine the image quality of digital mammographic equipment. Three phantoms were used: an American College of Radiology accreditation phantom, an MTM 100/R, and a tissue-equivalent phantom. Tungsten/silver target/filter material was used with four variable exposures (25, 28, 30, and 32 kVp). In total, there were 12 images. The images were evaluated by scoring the visibility of the structures, and a total score out of 100% was recorded. Statistical analysis was conducted using non-parametric tests. There was no significant difference in the visibility of structures among the phantoms at different kVp. However, there were significant differences (p=0.04) in the visibility of the tumor masses when the kVp was varied. In addition, visibility rates differed significantly between the three phantoms (p≤0.05). All the phantoms used in this study were suitable for evaluating digital mammography systems. However, the exposure setting for evaluation must be carefully considered. The tissue-equivalent phantom performed better in terms of the visibility rate to assess image quality in the digital mammography units.

  • Quality of images acquired with and without grid in digital mammography

    by Khaled H. Al Khalifah, Ajit Brindhaban, Raed A. Saeed

  • Radiation dose to premature infants in neonatal intensive care units in kuwait

    by A. Brindhaban, K. Al-Khalifah

    Entrance surface dose (ESD) and effective dose (E) to premature infants were estimated at three neonatal intensive care units in Kuwait for three standard X-ray examinations—abdominal, chest and skull X rays using a simple water phantom. The ESD was found to vary between 58 and 102 μGy for abdominal X rays, between 51 and 102 μGy for chest X rays and between 58 and 145 μGy for skull examinations. These doses are comparable to the entrance skin doses published elsewhere. The E-values were estimated using normalised organ dose dataset from the National Radiological Protection Board. The E-values for abdominal, chest and skull examinations were in the ranges of 30–46, 20–36 and 8–18 μSv per examination, respectively. The risk of developing childhood cancers from each of the three examinations was estimated to be in the range (9–117) × 10−6 for infants undergoing 25 of these X-ray examinations during their stay in the NIC unit.