Nathalie Collignon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nathalie Collignon has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Andrew J. Marshall
Healionics Corporation, Seattle, Washington, USA
1 shared publication - Benoit Detry
STAR Medical SA, Avenue Sabin 6, 1300, Wavre, Belgium
1 shared publication - Don Minckler
University of California, Irvine
1 shared publication - Ian Grierson
Department of Eye and Vision Science, Institute of Ageing and Chronic Disease, University of Liverpool, Liverpool, UK
1 shared publication - Jessica Bianco
NAMSA Clinical and Consulting, Chasse sur Rhone, France
1 shared publication - Marian K. Rippy
Rippy Pathology Solutions, Inc., Woodbury, MN, USA
1 shared publication
Latest Publications
- Open Access
- 14 October 2020
- Published by Springer Nature in BMC Biomedical Engineering
- Vol. 2 (1) , 1-11
A novel suprachoroidal microinvasive glaucoma implant: in vivo biocompatibility and biointegration
Background: A major challenge for any glaucoma implant is their ability to provide long-term intraocular pressure lowering efficacy. The formation of a low-permeability fibrous capsule around the device often leads to obstructed drainage channels, which may impair the drainage function of devices. These foreign body-related limitations point to the need to develop biologically inert biomaterials to improve performance in reaching long-term intraocular pressure reduction. The aim of this study was to evaluate in vivo (in rabbits) the ocular biocompatibility and tissue integration of a novel suprachoroidal microinvasive glaucoma implant, MINIject™ (iSTAR Medical, Wavre, Belgium). Results: In two rabbit studies, no biocompatibility issue was induced by the suprachoroidal, ab-externo implantation of the MINIject™ device. Clinical evaluation throughout the 6 post-operative months between the sham and test groups were similar, suggesting most reactions were related to the ab-externo surgical technique used for rabbits, rather than the implant material itself. Histological analysis of ocular tissues at post-operative months 1, 3 and 6 revealed that the implant was well-tolerated and induced only minimal fibroplasia and thus minimal encapsulation around the implant. The microporous structure of the device became rapidly colonized by cells, mostly by macrophages through cell migration, which do not, by their nature, impede the flow of aqueous humor through the device. Time-course analysis showed that once established, pore colonization was stable over time. No fibrosis nor dense connective tissue development were observed within any implant at any time point. The presence of pore colonization may be the process by which encapsulation around the implant is minimized, thus preserving the permeability of the surrounding tissues. No degradation nor structural changes of the implant occurred during the course of both studies. Conclusions: The novel MINIject™ microinvasive glaucoma implant was well-tolerated in ocular tissues of rabbits, with observance of biointegration, and no biocompatibility issues. Minimal fibrous encapsulation and stable cellular pore colonization provided evidence of preserved drainage properties over time, suggesting that the implant may produce a long-term ability to enhance aqueous outflow.
- 14 October 2020
- Published by Springer Nature in BMC Biomedical Engineering
- Vol. 2 (1) , 1-11
Open AccessA novel suprachoroidal microinvasive glaucoma implant: in vivo biocompatibility and biointegration
Background: A major challenge for any glaucoma implant is their ability to provide long-term intraocular pressure lowering efficacy. The formation of a low-permeability fibrous capsule around the device often leads to obstructed drainage channels, which may impair the drainage function of devices. These foreign body-related limitations point to the need to develop biologically inert biomaterials to improve performance in reaching long-term intraocular pressure reduction. The aim of this study was to evaluate in vivo (in rabbits) the ocular biocompatibility and tissue integration of a novel suprachoroidal microinvasive glaucoma implant, MINIject™ (iSTAR Medical, Wavre, Belgium). Results: In two rabbit studies, no biocompatibility issue was induced by the suprachoroidal, ab-externo implantation of the MINIject™ device. Clinical evaluation throughout the 6 post-operative months between the sham and test groups were similar, suggesting most reactions were related to the ab-externo surgical technique used for rabbits, rather than the implant material itself. Histological analysis of ocular tissues at post-operative months 1, 3 and 6 revealed that the implant was well-tolerated and induced only minimal fibroplasia and thus minimal encapsulation around the implant. The microporous structure of the device became rapidly colonized by cells, mostly by macrophages through cell migration, which do not, by their nature, impede the flow of aqueous humor through the device. Time-course analysis showed that once established, pore colonization was stable over time. No fibrosis nor dense connective tissue development were observed within any implant at any time point. The presence of pore colonization may be the process by which encapsulation around the implant is minimized, thus preserving the permeability of the surrounding tissues. No degradation nor structural changes of the implant occurred during the course of both studies. Conclusions: The novel MINIject™ microinvasive glaucoma implant was well-tolerated in ocular tissues of rabbits, with observance of biointegration, and no biocompatibility issues. Minimal fibrous encapsulation and stable cellular pore colonization provided evidence of preserved drainage properties over time, suggesting that the implant may produce a long-term ability to enhance aqueous outflow.
- 1 March 2009
- Published by Elsevier in Journal Français d'Ophtalmologie
- Vol. 32 (3) , 236-240
Les nouveaux systèmes de drainage de l’humeur aqueuse
- 1 March 2009
- Published by Elsevier in Journal Français d'Ophtalmologie
- Vol. 32 (3) , 236-240
Les nouveaux systèmes de drainage de l’humeur aqueuse
- 1 January 2006
- No. 300,p. 21-3
Abnormal cupping of the optic disc: clinical screening before performing a neuroimaging examination.
Imaging studies in typical glaucomatous cupping are usually needless. This article reviews the various clinical presentations for considering imaging in patients presenting with cupped disc.
- 1 January 2006
- No. 300,p. 21-3
Abnormal cupping of the optic disc: clinical screening before performing a neuroimaging examination.
Imaging studies in typical glaucomatous cupping are usually needless. This article reviews the various clinical presentations for considering imaging in patients presenting with cupped disc.
- 1 January 2005
- No. 296,p. 71-81
Emergencies in glaucoma: a review.
Most severe eye diseases and injuries ultimately require intervention by an ophthalmologist. The urgency of referral depends on various factors, including level of vision loss, duration of symptoms, and presence of comorbid diseases. Of special importance are five acute eye problems in which emergency management by primary care physicians can be critical to visual outcome: high-velocity injuries, chemical injuries, acute angle-closure glaucoma, arteritic ischemic optic neuropathy, and central retinal artery occlusion. This paper will focus on emergencies in glaucoma, especially primary and secondary closed-angle glaucoma and secondary open-angle glaucoma. Delay in presentation, and unresponsiveness to medical treatment of the acute ocular hypertension attack carry a significant risk of chronic glaucoma, whatever the mechanism of disease is. Whenever the acute glaucoma crisis does not cease with an appropriate medical treatment, a laser and/or surgical intervention needs to be urged.
- 1 January 2005
- No. 296,p. 71-81
Emergencies in glaucoma: a review.
Most severe eye diseases and injuries ultimately require intervention by an ophthalmologist. The urgency of referral depends on various factors, including level of vision loss, duration of symptoms, and presence of comorbid diseases. Of special importance are five acute eye problems in which emergency management by primary care physicians can be critical to visual outcome: high-velocity injuries, chemical injuries, acute angle-closure glaucoma, arteritic ischemic optic neuropathy, and central retinal artery occlusion. This paper will focus on emergencies in glaucoma, especially primary and secondary closed-angle glaucoma and secondary open-angle glaucoma. Delay in presentation, and unresponsiveness to medical treatment of the acute ocular hypertension attack carry a significant risk of chronic glaucoma, whatever the mechanism of disease is. Whenever the acute glaucoma crisis does not cease with an appropriate medical treatment, a laser and/or surgical intervention needs to be urged.