BKBurcu Kanat-Ertürk

Burcu Kanat-Ertürk

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Burcu Kanat-Ertürk has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Investigation of the effects of different denture base fabrication techniques and hard relining resin materials on the fixation of immediate provisional hybrid prosthesis to titanium cylinders

    by Burcu Kanat-Ertürk, Cansu Akarsu, Önjen Tak

    Background: Denture base fabrication techniques and hard relining resins play critical roles in the clinical durability of implant supported immediate provisional hybrid prostheses (IPHPs). This study aimed to investigate the effects of different denture base fabrication techniques and hard relining resins on the fixation of IPHPs to titanium cylinders using a push-out test, and observe the failure types. Methods: A total of 140 denture base acrylic resin specimens (diameter: 24 mm, height: 4 mm) were fabricated using four techniques: milling, 3D printing, injection molding, and conventional heat-polymerization. Holes in 10 mm diameter were drilled at the center of each specimen using an industrial drill. Then, titanium cylinders (Opus Implant) were fixed to the specimens using five hard relining resin materials: acrylic resin-based (Ufi Gel Hard)(UGH), heat-polymerized acrylic resin (Futura Basic Hot)(FBH), autopolymerizing composite resin (Quick Up)(QP), autopolymerizing denture repair resin based on diacrylate (Qu-resin)(QR), and autopolymerizing low shrinkage modelling acrylic resin (Pattern resin LS)(PR) (n = 7). Following 5000 thermal-cycles, a push-out test was performed using a universal testing machine (Test Control Systems). Data were statistically analyzed with two-way analysis of variance (ANOVA) and Tukey post-hoc test (SPSS26, p =.05). Results: Denture base fabrication techniques, hard relining resin materials, and their interactions had significant effects on the push-out forces (p <.001). Statistically significant differences among fabrication techniques were observed only in the QR group (p <.05), where heat-polymerization technique had the highest push-out forces. Among relining materials, PR exhibited the highest values for milling technique (p <.05). For 3D printing, PR (p =.007) and QR (p =.029) showed significantly higher values than UGH. For injection molding, PR was superior to QP (p =.012) and UGH (p =.001). For heat-polymerization technique, QR, PR and QP exhibited the higher values (p <.05). The most common failure type was adhesive failure between titanium cylinders and relining resins (ADHES-ti). Conclusions: Denture base fabrication techniques and relining resin types had significant effects on the push-out force. Conventional heat-polymerization technique provided the most consistent performance, whereas milling and 3D printing required careful selection of relining materials. These results can inform clinical decisions to improve IPHP durability and reduce complications.


    • 1 April 2025
      • Vol. 38  (2) , 93-99

    Push-out force evaluation of titanium cylinders attached to implant supported immediate provisional heat-polymerized acrylic resin with various relining material types and thicknesses.

    by Burcu Kanat-Ertürk, Gökçe Zengin, Önjen Tak

    To compare the laboratory push-out forces on titanium cylinders attached to immediate provisional heat-polymerized acrylic resins using different relining material types in varying thicknesses, and to investigate the fracture types. Heat-polymerized acrylic discs (Futura Basic Hot) (n= 105) were manufactured with artificial first molar teeth centered in each specimen (diameter: 24 mm, height:10 mm). Discs were drilled to create 6 mm, 8 mm and 10 mm diameter holes, corresponding to connection thicknesses of 1 mm, 2 mm, and 3 mm, respectively, around the 4 mm diameter titanium cylinders (n= 35/group). Each group was divided into five relining resin subgroups: Futura Basic Hot, Ufi Gel Hard, Qu-resin, Quick Up, and Pattern resin (n= 7/subgroup). Titanium cylinders were fixed into the holes, and the gaps were filled with relining resins. After 5,000 thermal cycles, a push-out test was performed (1 mm/minute). Data were analyzed with two-way ANOVA and Tukey post hoc tests (P= 0.05) and failure types were classified. Resin types, connection thicknesses, and their interaction significantly affected the push-out forces (P< 0.05). Futura Basic Hot showed the lowest push-out forces (171 ± 39 N, 317 ± 131 N, and 144 ± 78 N, for 1 mm, 2 mm, and 3 mm connection thickness groups, respectively) (P< 0.05). Qu-resin and Pattern resin had the highest push-out force for 1 mm (1,235 ± 375 N and 1,576 ± 272 N, respectively) and 3 mm (1,333 ± 127 N and 1,406 ± 82 N, respectively) connection thicknesses. Qu-resin, Ufi Gel Hard, Pattern resin, and Quick Up (2,065 ± 342 N, 1,835 ± 630 N, and 1,626 ± 106 N, 1,501 ± 312 N, respectively) all performed well for 2 mm (Plt; 0.05). 2 mm connection thickness resulted in the highest push-out forces, except for Pattern resin. Qu-resin and Pattern resin are suitable for all connection thicknesses, while Ufi Gel Hard and Quick-Up perform optimally with connection thickness of 2 mm. Futura Basic Hot results in weaker push-out forces for implant-supported immediate provisional hybrid prostheses (IPHPs) fixation. 2 mm connection thickness is generally recommended for improved push-out force. The choice of relining resin material and connection thickness significantly influence the push-out force on titanium cylinders attached to IPHPs. Selecting appropriate resin material types and thicknesses can enhance the long-term stability and clinical performance of IPHPs, reducing the risk of fractures during implant osseointegration period.

  • Open Access

    Fracture strength and marginal gap comparisons of monolayered and multilayered monolithic zirconia crowns with various milling depths

    by Gökçe Zengin, Burcu Kanat-Ertürk, Mine Dündar-Çömlekoğlu

    Zengin G, et al. J Adv Prosthodont. 2025 Oct;17(5):304-314. https://doi.org/10.4047/jap.2025.17.5.304


  • Open Access

    New monolithic post-core concept: a comparison of prefabricated and cad-cam fabricated postcores

    by Burcu Kanat Ertürk, Serkan Sarıdağ, Sinem Şahin, Ziya Safarlı, Dilek Helvacıoğlu Yiğit

    The aim of this in vitro study was to evaluate the fracture and pull-out strengths of various post–core systems. Forty-eight endodontically treated maxillary central incisors were assigned to three post–core groups: fiber post–composite core (RelyX) (FC), prefabricated monolithic fiber post–core (FiberSite) (MF), and CAD-CAM fabricated customized monolithic zirconia post–core (InCoris ZI) (MZ). Post–core designs were standardized according to the FiberSite system. After cementation (RelyX U200), the samples were divided into two mechanical test groups—fracture strength and pull-out strength (n = 8 per subgroup). Tests were performed at a crosshead speed of 1 mm/min, and failure types were recorded. For the fracture strength test, the highest values (N) were obtained in the MZ group. The difference between MF and FC was not statistically significant (p = 0.190). For the pull-out test, statistically significant differences (N) were found among all groups (p less than 0.001). The MZ group exhibited predominantly catastrophic failures in both tests, whereas the MF and FC groups mainly showed Type II and Type III failures. Within the limitations of this study, the FiberSite system appears to have clinical potential for restoring severely damaged teeth. This system offers a balance of mechanical strength and favorable failure modes compared with CAD-CAM zirconia post–cores, which demonstrated catastrophic failures, and fiber post–composite cores, which exhibited lower strength values.

  • Color Stability of CAD/CAM Ceramics Prepared with Different Surface Finishing Procedures

    by Burcu Kanat‐Ertürk

    Purpose: To investigate the color stability of zirconia‐reinforced lithium silicate glass‐ceramic and lithium disilicate reinforced glass‐ceramic, which were prepared with various surface finishing procedures, following 1‐week, 2‐week, 1‐month, and 2‐month storage in various beverages, and after the application of polishing paste.Materials and Methods: Lithium disilicate glass‐ceramic (IPS e.max CAD HT) and zirconia‐reinforced lithium silicate ceramic (Vita Suprinity HT) CAD/CAM blocks were sectioned with a diamond saw (Metkon) under water cooling into 1.5 × 7 × 12 mm dimensions (N = 120). All specimens were polished with silicon carbide paper (600‐, 800‐, and 1200‐grit) under water for 120 seconds. The specimens were prepared using 3 surface finishing procedures: glaze, mechanical polishing, and external staining and glaze in accordance with manufacturers’ instructions. Then, each group was divided into 2 storage subgroups, black tea and coffee (n = 10/group). Color values were measured in CIELAB color space with dental spectrophotometer (VITA Easyshade) at the initial stage, and following 1‐week, 2‐week, 1‐month, 2‐month storage, and after fine‐grit polishing paste application (Proxyt). Color changes (ΔE) were calculated and statistically analyzed using ANOVA followed by Bonferroni corrected post‐hoc tests using Number Cruncher Statistical System 2007 (α < 0.05).Results: For lithium disilicate glass‐ceramic, glaze procedure showed statistically lower color change values than mechanical polishing and external staining and glaze surface finishing groups (p < 0.05) following storage in both beverages, whereas for zirconia‐reinforced lithium silicate ceramic, glaze procedure showed statistically lower color change values than mechanical polishing, but statistically insignificant values with respect to external staining and glaze group, following storage in both beverages. Lithium disilicate glass‐ceramic groups showed statistically lower or statistically insignificant color change values with respect to zirconia‐reinforced lithium silicate ceramic groups, except for the external staining and glaze surface finishing group in coffee. Significantly lower discoloration values were obtained following polishing paste application, with respect to 2‐month storage in beverages (p < 0.05).Conclusion: Glazing alone led to more color stability with respect to mechanical polishing and external staining and glaze for zirconia‐reinforced lithium silicate and lithium disilicate glass‐ceramic. Lithium disilicate glass‐ceramic showed higher color stability compared to zirconia‐reinforced lithium silicate ceramic. Polishing paste resulted in a decrease in discoloration to clinically acceptable values.


  • Effect of Veneering Methods on Zirconia Framework—Veneer Ceramic Adhesion and Fracture Resistance of Single Crowns

    by Burcu Kanat‐Ertürk, Erhan M. Çömlekoğlu, Mine Dündar‐Çömlekoğlu, Mutlu Özcan, Mehmet Ali Güngör

    Purpose: The aim of this study was to evaluate the fracture resistance (FR) and shear bond strength (SBS) via finite element analysis (FEA) of zirconia framework veneered with different methods.Materials and Methods: Zirconia frameworks were prepared as crowns for FR and cubic blocks for SBS (N = 60, n = 10). The specimens were veneered with one of the following veneering methods: (a) overcemented file‐splitting (OCF), (b) layering (L), or (c) overpressing (P). For crowns, stainless steel dies (N = 30; chamfer: 1 mm) were scanned using a contrast spray. Bilayered design for OCF and reduced design (1 mm) for both L and P were performed by computer‐aided design and manufacturing. For the SBS test, zirconia blocks were sectioned (4 × 4 × 4 mm3) under water cooling and sintered. Frameworks were veneered with compatible ceramics for each veneering method and subjected to mechanical tests. The milled suprastructures were bonded to zirconia frameworks using a resin composite in Group OCF and photopolymerized. Crowns were cemented to the metal dies with resin modified glass‐ionomer cement. All specimens were stored at 37°C, 100% humidity for 48 hours prior to mechanical tests. Data were statistically analyzed (ANOVA, Bonferroni tests, α = 0.05). Fractured specimens were examined under scanning electron microscopy (SEM), and FEA modeling of the crowns was performed.Results: Mean FR values (N) were significantly higher with L (6102 ± 1519) and P (4117 ± 1083) than with of OCF (1900 ± 254) (p = 0.01). The mean SBS (MPa) in OCF (24 ± 4) was significantly lower (p < 0.002) than L (35 ± 6) and P (32 ± 6) (p > 0.05). For crown restorations, while only adhesive failures were found in OCF, cohesive failures within veneering ceramic were more frequent in P and L. FEA verified these findings.Conclusion: Veneering methods based on layering or pressing may reduce ceramic chipping but the overcemented file‐splitting method does not seem to prevent this failure.Clinical Significance: Layering and overpressing veneering methods on zirconia frameworks with reduced design might decrease chipping compared to overcemented file‐splitting, where in the latter, zirconia framework and feldspathic suprastructure are combined using a resin cement.


  • Microshear Bond Strength and Finite Element Analysis of Resin Composite Adhesion to Press-on-Metal Ceramic for Repair Actions after Various Conditioning Methods

    by Burcu Kanat, M Erhan Cömlekoğlu, Mine Dündar Cömlekoğlu, Osman Culha, Mutlu Ozcan, Mehmet Ali Güngör

    This study evaluated the repair bond strength of differently surface-conditioned press-on-metal ceramic to repair composites and determined the location of the accumulated stresses by finite element analysis. Press-on-metal ceramic disks (IPS InLine PoM, Ivoclar Vivadent) (N = 45, diameter: 3 mm, height: 2 mm) were randomly divided into 3 groups (n = 15 per group) and conditioned with one of the following methods: 9.5% hydrofluoric acid (HF) (Porcelain etch), tribochemical silica coating (TS) (CoJet), and an unconditioned group acted as the control (C). Each group was divided into three subgroups depending on the repair composite resins: a) Arabesk Top (V, a microhybrid; VOCO), b) Filtek Z250 (F, a hybrid;3M ESPE); c) Tetric EvoCeram (T, a nanohybrid; Ivoclar Vivadent) (n = 5 per subgroup). Repair composites disks (diameter: 1 mm, height: 1 mm) were photopolymerized on each ceramic block. Microshear bond strength (MSB) tests were performed (1 mm/min) and the obtained data were statistically analyzed using 2-way ANOVA and Tukey's post-hoc test (α = 0.05). Failure types were analyzed under SEM. Vickers indentation hardness, Young's modulus, and finite element analysis (FEA) were performed complementary to MSB tests to determine stress accumulation areas. MSB results were significantly affected by the surface conditioning methods (p = 0.0001), whereas the repair composite types did not show a significant effect (p = 0.108). The interaction terms between the repair composite and surface conditioning method were also statistically significant (p = 0.0001). The lowest MSB values (MPa ± SD) were obtained in the control group (V = 4 ± 0.8; F = 3.9 ± 0.7; T = 4.1 ± 0.7) (p < 0.05). While the group treated with T composite resulted in significantly lower MSB values for the HF group (T= 4.1 ± 0.8) compared to those of other composites (V = 8.1 ± 2.6; F = 7.6 ± 2.2) (p < 0.05), there were no significant differences when TS was used as a conditioning method (V = 5 ± 1.7; F = 4.7 ± 1; T = 6.2 ± 0.8) (p > 0.05). The control group presented exclusively adhesive failures. Cohesive failures in composite followed by mixed failure types were more common in HF and TS conditioned groups. Elasticity modulus of the composites were 22.9, 12.09, and 10.41 GPa for F, T, and V, respectively. Vickers hardness of the composites were 223, 232, and 375 HV for V, T, and F, respectively. Von Mises stresses in the FEA analysis for the V and T composites spread over a large area due to the low elastic modulus of the composite, whereas the F composite material accumulated more stresses at the bonded interface. Press-on-metal ceramic could best be repaired using tribochemical silica coating followed by silanization, regardless of the repair composite type in combination with their corresponding adhesive resins, providing that no cohesive ceramic failure was observed.


  • Effect of Various Veneering Techniques on Mechanical Strength of Computer‐Controlled Zirconia Framework Designs

    by Burcu Kanat, Erhan M. Çömlekoğlu, Mine Dündar‐Çömlekoğlu, Bilge Hakan Sen, Mutlu Özcan, Mehmet Ali Güngör

    Purpose: The objectives of this study were to evaluate the fracture resistance (FR), flexural strength (FS), and shear bond strength (SBS) of zirconia framework material veneered with different methods and to assess the stress distributions using finite element analysis (FEA).Materials and Methods: Zirconia frameworks fabricated in the forms of crowns for FR, bars for FS, and disks for SBS (N = 90, n = 10) were veneered with either (a) file splitting (CAD‐on) (CD), (b) layering (L), or (c) overpressing (P) methods. For crown specimens, stainless steel dies (N = 30; 1 mm chamfer) were scanned using the labside contrast spray. A bilayered design was produced for CD, whereas a reduced design (1 mm) was used for L and P to support the veneer by computer‐aided design and manufacturing. For bar (1.5 × 5 × 25 mm3) and disk (2.5 mm diameter, 2.5 mm height) specimens, zirconia blocks were sectioned under water cooling with a low‐speed diamond saw and sintered. To prepare the suprastructures in the appropriate shapes for the three mechanical tests, nano‐fluorapatite ceramic was layered and fired for L, fluorapatite‐ceramic was pressed for P, and the milled lithium‐disilicate ceramics were fused with zirconia by a thixotropic glass ceramic for CD and then sintered for crystallization of veneering ceramic. Crowns were then cemented to the metal dies. All specimens were stored at 37°C, 100% humidity for 48 hours. Mechanical tests were performed, and data were statistically analyzed (ANOVA, Tukey's, α = 0.05). Stereomicroscopy and scanning electron microscopy (SEM) were used to evaluate the failure modes and surface structure. FEA modeling of the crowns was obtained.Results: Mean FR values (N ± SD) of CD (4408 ± 608) and L (4323 ± 462) were higher than P (2507 ± 594) (p < 0.05). Mean FS values (MPa ± SD) of CD (583 ± 63) and P (566 ± 54) were higher than L (428 ± 41) (p < 0.05). Mean SBS values (MPa ± SD) of CD (49 ± 6) (p < 0.05) were higher than L (28 ± 5) and P (30 ± 8). For crown restorations, while cohesive failures within ceramic and zirconia were seen in CD, cohesive failures within ceramic were found in both L and P. Results were verified by FEA.Conclusion: The file splitting technique showed higher bonding values in all mechanical tests, whereas a layering technique increased the FR when an anatomical core design was employed. Clinical significance: File splitting (CAD‐on) or layering veneering ceramic on zirconia with a reduced framework design may reduce ceramic chipping.