Wilson M. Chang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Wilson M. Chang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- George Stetten
University of Pittsburgh, Pittsburgh, PA USA
2 shared publications - Roberta L. Klatzky
Carnegie Mellon University
2 shared publications Albert B. Zajko
1 shared publication- David C. Wang
University of Pittsburgh Medical Center, Pittsburgh, PA
1 shared publication - David Weiser
University of Pittsburgh Department of Bioengineering
1 shared publication - Gaurav Shukla
Radiation Oncology, University of Pennsylvania, Philadelphia, PA, 19107, USA
1 shared publication
Latest Publications
- 1 October 2009
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 20 (10) , 1380-1383
Peripherally Inserted Central Catheter Placement Using the Sonic Flashlight
- 1 October 2009
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 20 (10) , 1380-1383
Peripherally Inserted Central Catheter Placement Using the Sonic Flashlight
- 1 December 2006
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 241 (3) , 771-779
Vascular Access: Comparison of US Guidance with the Sonic Flashlight and Conventional US in Phantoms
To prospectively evaluate whether ultrasonography (US)-guided vascular access can be learned and performed faster with the sonic flashlight than with conventional US and to demonstrate sonic flashlight-guided vascular access in a cadaver. Institutional review board approval and oral and written informed consent were obtained. The sonic flashlight replaces the standard US monitor with a real-time US image that appears to float beneath the skin and is displayed where it is scanned. In studies 1 and 2, participants performed sonic flashlight-guided needle insertion tasks in vascular phantoms. In study 1, 16 participants (nine women, seven men) with no US experience performed 60 simulated vascular access trials with sonic flashlight or conventional US guidance. With analysis of variance (ANOVA) and power-curve fitting, improvement with practice rate and mean differences between techniques and tasks were examined. In study 2, 14 female nurses (mean age, 50.1 years) proficient with conventional US performed simulated vascular access trials on three tasks with the sonic flashlight and conventional US. With random assignment, half the participants used the sonic flashlight first and half used conventional US first. Mean performance with each technique and that with each task were compared by using ANOVA. In study 3, feasibility of sonic flashlight guidance for access to internal jugular and basilic veins was demonstrated in a cadaver. For study 1, learning rates (ie, decrease in access time over trials) did not differ for vascular access with sonic flashlight and conventional US. Overall, participants achieved faster vascular access times with sonic flashlight guidance (P < .007). In study 2, participants performed procedures faster overall with the sonic flashlight (P < .02) and found the sonic flashlight easier to use. In study 3, sonic flashlight-guided vascular access was gained in the cadaver. Learning and performance of vascular access were significantly faster with the sonic flashlight than with conventional US, and vascular access could be gained in a cadaver; the sonic flashlight is ready for clinical trials.
- 1 December 2006
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 241 (3) , 771-779
Vascular Access: Comparison of US Guidance with the Sonic Flashlight and Conventional US in Phantoms
To prospectively evaluate whether ultrasonography (US)-guided vascular access can be learned and performed faster with the sonic flashlight than with conventional US and to demonstrate sonic flashlight-guided vascular access in a cadaver. Institutional review board approval and oral and written informed consent were obtained. The sonic flashlight replaces the standard US monitor with a real-time US image that appears to float beneath the skin and is displayed where it is scanned. In studies 1 and 2, participants performed sonic flashlight-guided needle insertion tasks in vascular phantoms. In study 1, 16 participants (nine women, seven men) with no US experience performed 60 simulated vascular access trials with sonic flashlight or conventional US guidance. With analysis of variance (ANOVA) and power-curve fitting, improvement with practice rate and mean differences between techniques and tasks were examined. In study 2, 14 female nurses (mean age, 50.1 years) proficient with conventional US performed simulated vascular access trials on three tasks with the sonic flashlight and conventional US. With random assignment, half the participants used the sonic flashlight first and half used conventional US first. Mean performance with each technique and that with each task were compared by using ANOVA. In study 3, feasibility of sonic flashlight guidance for access to internal jugular and basilic veins was demonstrated in a cadaver. For study 1, learning rates (ie, decrease in access time over trials) did not differ for vascular access with sonic flashlight and conventional US. Overall, participants achieved faster vascular access times with sonic flashlight guidance (P < .007). In study 2, participants performed procedures faster overall with the sonic flashlight (P < .02) and found the sonic flashlight easier to use. In study 3, sonic flashlight-guided vascular access was gained in the cadaver. Learning and performance of vascular access were significantly faster with the sonic flashlight than with conventional US, and vascular access could be gained in a cadaver; the sonic flashlight is ready for clinical trials.