JLJiaping Liu

Jiaping Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jiaping Liu has a total of 18 co-authors. Here are the top co-authors by number of shared publications:

  • Jingchao Xie

    Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing 100124, China

    4 shared publications
  • Peng Xue

    Beijing Key Laboratory of Green Building Environment and Energy Saving Technology, Beijing University of Technology, Beijing 100124, China

    4 shared publications
  • Bin Wang

    Beijing Capital Development Co., Ltd., Shoukai Zhixin Branch, Beijing 100020, China

    1 shared publication
  • Jiaxin Shi

    Beijing Key Laboratory of Green Building Environment and Energy Saving Technology, Beijing University of Technology, Beijing 100124, China

    1 shared publication
  • Ling Jin

    Beijing Capital Development Co., Ltd., Shoukai Zhixin Branch, Beijing 100020, China

    1 shared publication
  • Ling Jin

    Beijing Key Laboratory of Green Building Environment and Energy Saving Technology, Beijing University of Technology, Beijing 100124, China

    1 shared publication

Latest Publications

  • Open Access

    Status of Typical Artificial Lighting Environments in Different Public Buildings in China, and Requirements for Their Improvement

    by Qingxuan Liang, Ling Jin, Tao Luo, Jiaxin Shi, Peng Xue, Jiaping Liu, Bin Wang, Xuan Jin

    The luminous environment is an essential factor that affects people’s working and living experiences in buildings. In order to clarify the building luminous environment parameters that are required for occupant satisfaction, we collected 2553 completed questionnaires while conducting field measurements of new and updated luminous comfort metrics in 15 contexts in four cities in China. By developing a five-step approach to identifying the luminous environment needs of different building occupants, including data cleaning, correlation analysis, and nonparametric testing, we determined the thresholds for all key metrics for each scenario. The research results show that different public building environments have unique luminous environment improvement requirements, and this conclusion can guide future lighting design, LED technology and daylighting integration technology.


  • Open Access

    Simplified Model of Heat Load Prediction and Its Application in Estimation of Building Envelope Thermal Performance

    by Ziyang Hao, Jingchao Xie, Xiaojing Zhang, Jiaping Liu

    This study provides a reference for estimating the building envelope thermal performance at the initial stage of design for nearly zero-energy buildings in different climate zones. A simplified model of heat load prediction, which combines the quasi-steady-state thermal balance calculation procedure in ISO 52016 and the variable-base degree-days method, was proposed. Therefore, a building energy performance evaluation tool BPT V1.0 was developed. Subsequently, the simplified model was validated through comparative analysis with the Building Energy Simulation Test (BESTEST) standard procedure. To conduct a feasibility analysis of the development tool, case studies were performed on the performance evaluation of building envelopes of residential and office buildings in different climate zones in China. Compared to the simulation results from EnergyPlus, the deviation of heat load calculated by BPT V1.0 was within 10%, which further verifies the applicability of the tool under different climatic conditions. Annual heat load under different thermal performance building envelopes was calculated through BPT V1.0. The building energy efficiency improvement rates were found to range from 30 to 60% in nearly zero-energy buildings in different climate zones in China. The study results can provide a reference for energy managers and a basis for estimating the building energy efficiency performance with different envelope thermal properties in the region.


  • Open Access

    A Novel Evaluation Method of Tunnel Access Zone Luminance Based on Measured Meteorological Data

    by Yuwei Zhang, Peng Xue, Yifan Zhao, Zhikai Ni, Yani Quan, Jingchao Xie, Jiaping Liu

    As the design basis of the tunnel lighting system, tunnel access zone luminance (TAZL) directly affects the energy efficiency of the tunnel lighting system and the driving safety of drivers. Affected by the relative position of the sun, weather conditions and other factors, the TAZL dynamically changes over time, but the existing tunnel mostly uses a fixed luminance value for the design and operation of the tunnel lighting system, which lacks a simplified method to obtain the real-time luminance. In this study, the L20(S) (the average luminance observed by the driver at 20° field of view) at the tunnel stopping sight distance is split, and the sky luminance is calculated by using the sky luminance model. While a segmented prediction model of the ground scenery luminance is established with the maximum sun height angle as the inflection point, the solar irradiance outside the tunnel is adopted as the input parameter. This new proposed L20(S) evaluation model is verified within the error of 5.41%, which provides a convenient and accurate method for the real-time measurement of TAZL.


  • Open Access

    Experimental and Theoretical Study on the Heat Transfer Coefficients of Building External Surfaces in the Tropical Island Region

    by Yaping Cui, Jingchao Xie, Jiaping Liu, Peng Xue

    China is actively promoting ocean territory construction, and how to design low-energy buildings to fit the unique climate of tropical island regions has received much attention. The heat transfer coefficient of a building external surface plays a vital role in calculating air-conditioning load accurately. To obtain reasonable heat transfer coefficients in the tropical island region, this study introduced a naphthalene sublimation experiment to conduct full-scale measurements on convective heat transfer coefficients (CHTCs) in the tropical island region, and proposed a simplified calculation model of evaporative heat transfer coefficients (EHTCs). Results indicated that the function expression between CHTC and wind speed was CHTC = 5.56 + 4.48u (R2 = 0.94), and it was validated to be reliable. Furthermore, compared with CHTCs and radiation heat transfer coefficients (RHTCs), the EHTC had a wider changing range, owing to rainfall effects. Moreover, whether evaporation was considered or not, the difference of total heat transfer coefficients (THTCs) on building external surfaces was 5.2 W/(m2·K) for the whole year, so evaporation cannot be ignored directly. Additionally, THTCs with consideration of evaporation in winter and summer were 33.4 W/(m2·K) and 38.9 W/(m2·K) severally, which are much larger than the recommended values in the Chinese standard. This study would make up for the lack of surface heat transfer coefficients in energy conservation design of tropical island buildings.