Jiaxin Shi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jiaxin Shi has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Peng Xue
Beijing Key Laboratory of Green Building Environment and Energy Saving Technology, Beijing University of Technology, Beijing 100124, China
2 shared publications - Qingxuan Liang
Logistics Service Center of the Chinese Academy of Forestry, Chinese Academy of Forestry, Beijing 100091, China
2 shared publications - Bin Wang
Beijing Capital Development Co., Ltd., Shoukai Zhixin Branch, Beijing 100020, China
1 shared publication - Guiyi Wu
Real Estate Development Co., Ltd., China Railway 22nd Bureau Group, Beijing 100041, China
1 shared publication - Jiaping Liu
Beijing Key Laboratory of Green Building Environment and Energy Saving Technology, Beijing University of Technology, Beijing 100124, China
1 shared publication - Ling Jin
Beijing Capital Development Co., Ltd., Shoukai Zhixin Branch, Beijing 100020, China
1 shared publication
Latest Publications
- Open Access
Multidimensional Human Responses Under Dynamic Spectra of Daylighting and Electric Lighting
The luminous environment, shaped by daylight and electric light, significantly influences visual performance, physiological responses, and perceptual experiences. While these light sources are often perceived as distinct due to their differing effects on occupants’ cognition and well-being, the underlying mechanisms remain unclear. Nine lighting conditions were evaluated, combining three spectral types—daylight (DL), conventional LED (CLED), and daylight LED (DLED)—with three horizontal illuminance levels (300 lx, 500 lx, and 1000 lx). Twelve healthy subjects completed visual performance tasks (2-back working memory test), physiological measurements (heart rate variability and critical flicker frequency), and subjective evaluations. The results revealed that 500 lx consistently yielded the most favorable outcomes: 2-back task response speed improved by 6.2% over 300 lx and 1000 lx, and the critical flicker frequency difference was smallest, indicating reduced fatigue. DLED lighting achieved cognitive and physiological levels comparable to daylight. Heart rate variability analyzes further confirmed higher alertness levels under 500 lx DLED lighting (LF/HF = 3.31). Subjective ratings corroborated these findings, with perceived alertness and comfort highest under DLED and 500 lx conditions. These results demonstrate that DLED, which offers a balanced spectral composition and improved uniformity, may serve as an effective lighting configuration for supporting both visual and non-visual performance in indoor settings lacking daylight.
Open AccessMultidimensional Human Responses Under Dynamic Spectra of Daylighting and Electric Lighting
The luminous environment, shaped by daylight and electric light, significantly influences visual performance, physiological responses, and perceptual experiences. While these light sources are often perceived as distinct due to their differing effects on occupants’ cognition and well-being, the underlying mechanisms remain unclear. Nine lighting conditions were evaluated, combining three spectral types—daylight (DL), conventional LED (CLED), and daylight LED (DLED)—with three horizontal illuminance levels (300 lx, 500 lx, and 1000 lx). Twelve healthy subjects completed visual performance tasks (2-back working memory test), physiological measurements (heart rate variability and critical flicker frequency), and subjective evaluations. The results revealed that 500 lx consistently yielded the most favorable outcomes: 2-back task response speed improved by 6.2% over 300 lx and 1000 lx, and the critical flicker frequency difference was smallest, indicating reduced fatigue. DLED lighting achieved cognitive and physiological levels comparable to daylight. Heart rate variability analyzes further confirmed higher alertness levels under 500 lx DLED lighting (LF/HF = 3.31). Subjective ratings corroborated these findings, with perceived alertness and comfort highest under DLED and 500 lx conditions. These results demonstrate that DLED, which offers a balanced spectral composition and improved uniformity, may serve as an effective lighting configuration for supporting both visual and non-visual performance in indoor settings lacking daylight.
- Open Access
Status of Typical Artificial Lighting Environments in Different Public Buildings in China, and Requirements for Their Improvement
The luminous environment is an essential factor that affects people’s working and living experiences in buildings. In order to clarify the building luminous environment parameters that are required for occupant satisfaction, we collected 2553 completed questionnaires while conducting field measurements of new and updated luminous comfort metrics in 15 contexts in four cities in China. By developing a five-step approach to identifying the luminous environment needs of different building occupants, including data cleaning, correlation analysis, and nonparametric testing, we determined the thresholds for all key metrics for each scenario. The research results show that different public building environments have unique luminous environment improvement requirements, and this conclusion can guide future lighting design, LED technology and daylighting integration technology.
Open AccessStatus of Typical Artificial Lighting Environments in Different Public Buildings in China, and Requirements for Their Improvement
The luminous environment is an essential factor that affects people’s working and living experiences in buildings. In order to clarify the building luminous environment parameters that are required for occupant satisfaction, we collected 2553 completed questionnaires while conducting field measurements of new and updated luminous comfort metrics in 15 contexts in four cities in China. By developing a five-step approach to identifying the luminous environment needs of different building occupants, including data cleaning, correlation analysis, and nonparametric testing, we determined the thresholds for all key metrics for each scenario. The research results show that different public building environments have unique luminous environment improvement requirements, and this conclusion can guide future lighting design, LED technology and daylighting integration technology.