Ling Jin
Ling Jin has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Peng Xue
Beijing Key Laboratory of Green Building Environment and Energy Saving Technology, Beijing University of Technology, Beijing 100124, China
2 shared publications - Bin Wang
Beijing Capital Development Co., Ltd., Shoukai Zhixin Branch, Beijing 100020, China
1 shared publication - Jiaping Liu
Beijing Key Laboratory of Green Building Environment and Energy Saving Technology, Beijing University of Technology, Beijing 100124, China
1 shared publication - Jiaxin Shi
Beijing Key Laboratory of Green Building Environment and Energy Saving Technology, Beijing University of Technology, Beijing 100124, China
1 shared publication - Junhua Liao
Beijing Key Laboratory of Green Building Environment and Energy Saving Technology, Beijing University of Technology, Beijing 100124, China
1 shared publication - Junjie Liu
Tianjin University
1 shared publication
Latest Publications
- Open Access
Status of Typical Artificial Lighting Environments in Different Public Buildings in China, and Requirements for Their Improvement
The luminous environment is an essential factor that affects people’s working and living experiences in buildings. In order to clarify the building luminous environment parameters that are required for occupant satisfaction, we collected 2553 completed questionnaires while conducting field measurements of new and updated luminous comfort metrics in 15 contexts in four cities in China. By developing a five-step approach to identifying the luminous environment needs of different building occupants, including data cleaning, correlation analysis, and nonparametric testing, we determined the thresholds for all key metrics for each scenario. The research results show that different public building environments have unique luminous environment improvement requirements, and this conclusion can guide future lighting design, LED technology and daylighting integration technology.
Open AccessStatus of Typical Artificial Lighting Environments in Different Public Buildings in China, and Requirements for Their Improvement
The luminous environment is an essential factor that affects people’s working and living experiences in buildings. In order to clarify the building luminous environment parameters that are required for occupant satisfaction, we collected 2553 completed questionnaires while conducting field measurements of new and updated luminous comfort metrics in 15 contexts in four cities in China. By developing a five-step approach to identifying the luminous environment needs of different building occupants, including data cleaning, correlation analysis, and nonparametric testing, we determined the thresholds for all key metrics for each scenario. The research results show that different public building environments have unique luminous environment improvement requirements, and this conclusion can guide future lighting design, LED technology and daylighting integration technology.
- Open Access
- 12 May 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (10) , 5861
Optimization of Corrugated Sheet Packing Structure Based on Analysis of Falling Film Flow Characteristics
The falling film flow characteristics of a liquid on the surface of corrugated sheet packing are crucial for its mass transfer performance in various industrial applications. In this study, a falling film flow experiment with laser-induced fluorescence technology was conducted to validate the flow characteristics of a falling film simulated using computational fluid dynamics (CFD). The influences of Reynolds number (Re) and the packing structure on flow characteristics were analyzed with quantitative film thickness and wetted area obtained through three-dimensional simulation. The results show that the CFD model can accurately predict the liquid falling–film flow behavior and calculate the characteristic parameters. For sinusoidal corrugated sheets, when Re reaches 500, the groove flow changes into a rivulet flow along the adjacent ripples and the wetted area is at its largest, about 0.022 m2. However, relative to the geometric area of the corrugated sheet, the wetted area can only reach 20% of the surface area, and the overall wetting performance is still poor. Triangular and trapezoidal corrugated sheets were further proposed and proved to improve the wetting area compared with the sinusoidal sheet, with maximum increases of 23% and 9%, respectively. On this basis, extensive research was carried out on the corrugation angle. The results show that a triangular corrugated sheet with a 75° corrugated angle was more conducive to the flow of the liquid film, and the wetted area was 38.8% of the surface area.
- 12 May 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (10) , 5861
Open AccessOptimization of Corrugated Sheet Packing Structure Based on Analysis of Falling Film Flow Characteristics
The falling film flow characteristics of a liquid on the surface of corrugated sheet packing are crucial for its mass transfer performance in various industrial applications. In this study, a falling film flow experiment with laser-induced fluorescence technology was conducted to validate the flow characteristics of a falling film simulated using computational fluid dynamics (CFD). The influences of Reynolds number (Re) and the packing structure on flow characteristics were analyzed with quantitative film thickness and wetted area obtained through three-dimensional simulation. The results show that the CFD model can accurately predict the liquid falling–film flow behavior and calculate the characteristic parameters. For sinusoidal corrugated sheets, when Re reaches 500, the groove flow changes into a rivulet flow along the adjacent ripples and the wetted area is at its largest, about 0.022 m2. However, relative to the geometric area of the corrugated sheet, the wetted area can only reach 20% of the surface area, and the overall wetting performance is still poor. Triangular and trapezoidal corrugated sheets were further proposed and proved to improve the wetting area compared with the sinusoidal sheet, with maximum increases of 23% and 9%, respectively. On this basis, extensive research was carried out on the corrugation angle. The results show that a triangular corrugated sheet with a 75° corrugated angle was more conducive to the flow of the liquid film, and the wetted area was 38.8% of the surface area.