Beyhan Bayhan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Beyhan Bayhan has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Gökhan Özdemi̇r
Department of Civil Engineering, Bursa Technical University, Bursa 16310, Türkiye
3 shared publications - Deniz Birlik Kayı
Department of Civil Engineering, Bursa Technical University, Bursa 16310, Türkiye
2 shared publications Gokhan Ozdemir
Seismic Isolation Test Center Eskisehir Technical University 2 Eylul Campus Eskisehir Turkey 26555
2 shared publicationsDeniz Birlik Kayı
1 shared publicationEray Yıldırım
1 shared publicationEsengul Cavdar
Seismic Isolation Test Center Eskisehir Technical University 2 Eylul Campus Eskisehir Turkey 26555
1 shared publication
Latest Publications
- Open Access
- 28 April 2026
- Published by Springer Nature in Bulletin of Earthquake Engineering
- p. 1-29
Effect of superstructure characteristics on seismic response of an RC building retrofitted with lead rubber bearings
This paper investigates the change in seismic demands of a reinforced concrete (RC) building retrofitted by seismic isolation technique, due to change in superstructure characteristics. First, an RC building that possesses the general characteristics of fixed-base building stock in Türkiye is identified. Then, it is retrofitted by means of Lead Rubber Bearings (LRBs) and subjected to bidirectional ground motion excitations through nonlinear response history analyses (NRHA). Concrete compressive strength, dimensions of both beams and columns, and first story height are the parameters considered in the analyses. Two different numerical models are established by considering both linear and nonlinear element definitions for the superstructure. In either case, LRBs are represented by deteriorating hysteretic force-displacement relations that consider the effect of heating in the lead core during cyclic motion. Results indicate that increasing the beam dimensions is the most effective approach in retrofitting of the analyzed structural model to reduce inter-story drift ratios (ISDRs). An increase in beam dimensions led to an approximately 30% reduction in ISDRs, while enhancements in concrete compressive strength and dimensions of columns yielded reductions of nearly 20%. The elastic superstructure model may lead to underestimated ISDRs by more than 1.5 folds compared to its nonlinear counterpart.
- 28 April 2026
- Published by Springer Nature in Bulletin of Earthquake Engineering
- p. 1-29
Open AccessEffect of superstructure characteristics on seismic response of an RC building retrofitted with lead rubber bearings
This paper investigates the change in seismic demands of a reinforced concrete (RC) building retrofitted by seismic isolation technique, due to change in superstructure characteristics. First, an RC building that possesses the general characteristics of fixed-base building stock in Türkiye is identified. Then, it is retrofitted by means of Lead Rubber Bearings (LRBs) and subjected to bidirectional ground motion excitations through nonlinear response history analyses (NRHA). Concrete compressive strength, dimensions of both beams and columns, and first story height are the parameters considered in the analyses. Two different numerical models are established by considering both linear and nonlinear element definitions for the superstructure. In either case, LRBs are represented by deteriorating hysteretic force-displacement relations that consider the effect of heating in the lead core during cyclic motion. Results indicate that increasing the beam dimensions is the most effective approach in retrofitting of the analyzed structural model to reduce inter-story drift ratios (ISDRs). An increase in beam dimensions led to an approximately 30% reduction in ISDRs, while enhancements in concrete compressive strength and dimensions of columns yielded reductions of nearly 20%. The elastic superstructure model may lead to underestimated ISDRs by more than 1.5 folds compared to its nonlinear counterpart.
- Open Access
Effectiveness of Seismic Isolation Technique as a Retrofit Solution in the Case of an RC Building with Corroded Reinforcement
This paper aims to quantify the change in seismic response of a reinforced concrete (RC) building retrofitted by the seismic isolation technique when reinforcement corrosion is considered. In this regard, an 8-story RC building that possesses the characteristics of the existing fixed-base building stock in Türkiye has been identified and hypothetically retrofitted with lead rubber bearings (LRBs). In the numerical models, four different corrosion scenarios to represent the spatial distribution of corrosion on the frame elements of the superstructure and three different corrosion levels considering the mass losses (5, 10 and 20%) due to corrosion are considered; the corresponding reductions in (i) the cross-sectional areas of both the longitudinal and transverse reinforcements and (ii) the mechanical properties of steel and concrete are taken into account. Code-based bidirectional nonlinear response history analyses (NRHAs) are performed by considering the nonlinearity not only in the seismic isolation system but also in the superstructure. Furthermore, LRBs are represented by a force–displacement relation that enables modeling of the deterioration in strength of isolators due to lead core heating during cyclic motion. The results revealed that the spatial distribution of the corrosion is highly effective in amplification of inter-story drift ratios (ISDRs), which can be in the order of 2-fold depending on the level of mass loss. It is found that the seismic isolation technique is still effective in protecting the superstructure against earthquakes even though there is a corrosion problem in frame members.
Open AccessEffectiveness of Seismic Isolation Technique as a Retrofit Solution in the Case of an RC Building with Corroded Reinforcement
This paper aims to quantify the change in seismic response of a reinforced concrete (RC) building retrofitted by the seismic isolation technique when reinforcement corrosion is considered. In this regard, an 8-story RC building that possesses the characteristics of the existing fixed-base building stock in Türkiye has been identified and hypothetically retrofitted with lead rubber bearings (LRBs). In the numerical models, four different corrosion scenarios to represent the spatial distribution of corrosion on the frame elements of the superstructure and three different corrosion levels considering the mass losses (5, 10 and 20%) due to corrosion are considered; the corresponding reductions in (i) the cross-sectional areas of both the longitudinal and transverse reinforcements and (ii) the mechanical properties of steel and concrete are taken into account. Code-based bidirectional nonlinear response history analyses (NRHAs) are performed by considering the nonlinearity not only in the seismic isolation system but also in the superstructure. Furthermore, LRBs are represented by a force–displacement relation that enables modeling of the deterioration in strength of isolators due to lead core heating during cyclic motion. The results revealed that the spatial distribution of the corrosion is highly effective in amplification of inter-story drift ratios (ISDRs), which can be in the order of 2-fold depending on the level of mass loss. It is found that the seismic isolation technique is still effective in protecting the superstructure against earthquakes even though there is a corrosion problem in frame members.
- Top Cited Papers
- 8 April 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 89
Reconnaissance report on damage caused by the February 6, 2023, Kahramanmaraş Earthquakes in reinforced-concrete structures
- 8 April 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 89
Top Cited PapersReconnaissance report on damage caused by the February 6, 2023, Kahramanmaraş Earthquakes in reinforced-concrete structures
- 22 November 2023
- Published by Elsevier in Structures
- Vol. 58
Effects of modeling assumptions on prediction of seismic demands of a single-story RC structure
- 22 November 2023
- Published by Elsevier in Structures
- Vol. 58
Effects of modeling assumptions on prediction of seismic demands of a single-story RC structure
- Open Access
- 30 October 2023
- Published by Springer Nature in Heritage Science
- Vol. 11 (1) , 1-18
Damage assessment and restoration proposal following the 2023 Türkiye earthquakes: UNESCO World Heritage Site Diyarbakır City Walls, Türkiye
Diyarbakır City Walls, one of the longest defensive structures in the world, following the Great Wall of China, the walls of Antakya, and the walls of Istanbul, is a UNESCO World Heritage site since 2015. With a history of approximately 5000 years, the Diyarbakır City Walls have been affected by consecutive earthquakes centered in Kahramanmaraş in 2023, resulting in damages to various sections. Urgent restoration and repair interventions are needed for these sections of the Diyarbakır City Walls due to earthquake-induced damages. Although there are limited studies presenting stone analysis of the Diyarbakır City Walls in the literature, no studies focusing on mortar analysis have been found. The objectives of this study are as follows: (I) to identify the mechanisms and factors of earthquake damages in the Diyarbakır City Walls, (II) to conduct necessary analyses for the selection of mortar materials for post-earthquake repairs, and (III) to provide restoration and strengthening recommendations to ensure the sustainability of the original structure. Observational, petrographic, chemical, and SEM analysis techniques were used, and the findings were interpreted comparatively. The results demonstrate that the most severe damages after the earthquake in the Diyarbakır City Walls were caused by the inadequate adhesion of missing mortar joints and different types of materials used between double-walled structures. Additionally, the presence of clay minerals identified in the mineralogy of the mortar through experimental analysis was defined as an internal issue causing the loss of mortar due to osmotic pressure created by water absorption. Another factor causing the loss of mortar is the presence of chloride-type salts, which were found to be present in a significant amount in all samples and were attributed to the use of Portland cement in previous faulty repairs. It was also determined that recent faulty repointing works contributed to the loss of mortar. Finally, this article presents original restoration and strengthening recommendations to repair the earthquake-induced damages and prevent their reoccurrence in the future.
- 30 October 2023
- Published by Springer Nature in Heritage Science
- Vol. 11 (1) , 1-18
Open AccessDamage assessment and restoration proposal following the 2023 Türkiye earthquakes: UNESCO World Heritage Site Diyarbakır City Walls, Türkiye
Diyarbakır City Walls, one of the longest defensive structures in the world, following the Great Wall of China, the walls of Antakya, and the walls of Istanbul, is a UNESCO World Heritage site since 2015. With a history of approximately 5000 years, the Diyarbakır City Walls have been affected by consecutive earthquakes centered in Kahramanmaraş in 2023, resulting in damages to various sections. Urgent restoration and repair interventions are needed for these sections of the Diyarbakır City Walls due to earthquake-induced damages. Although there are limited studies presenting stone analysis of the Diyarbakır City Walls in the literature, no studies focusing on mortar analysis have been found. The objectives of this study are as follows: (I) to identify the mechanisms and factors of earthquake damages in the Diyarbakır City Walls, (II) to conduct necessary analyses for the selection of mortar materials for post-earthquake repairs, and (III) to provide restoration and strengthening recommendations to ensure the sustainability of the original structure. Observational, petrographic, chemical, and SEM analysis techniques were used, and the findings were interpreted comparatively. The results demonstrate that the most severe damages after the earthquake in the Diyarbakır City Walls were caused by the inadequate adhesion of missing mortar joints and different types of materials used between double-walled structures. Additionally, the presence of clay minerals identified in the mineralogy of the mortar through experimental analysis was defined as an internal issue causing the loss of mortar due to osmotic pressure created by water absorption. Another factor causing the loss of mortar is the presence of chloride-type salts, which were found to be present in a significant amount in all samples and were attributed to the use of Portland cement in previous faulty repairs. It was also determined that recent faulty repointing works contributed to the loss of mortar. Finally, this article presents original restoration and strengthening recommendations to repair the earthquake-induced damages and prevent their reoccurrence in the future.
- 1 November 2019
- Published by Wiley in Earthquake Spectra
- Vol. 35 (4) , 1663-1688
Significance of Ground Motion Scaling Parameters on Amplitude of Scale Factors and Seismic Response of Short‐ and Long‐Period Structures
In this study, an ensemble of ground motions is selected and scaled in order to perform code‐compliant bidirectional Nonlinear Response History Analysis for the design purpose of both short‐ and long‐period structures. The followed scaling method provides both the requirements of the Turkish Earthquake Code regarding the scaling of ground motions and compatibility of response spectra of selected ground motion pairs with the target spectrum. The effects of four parameters, involved in the followed scaling method, on both the amplitude of scale factors and seismic response of structures are investigated. These parameters are the number of ground motion records, period range, number of periods used in the related period range, and distribution of weight factors at the selected periods. In the analyses, ground motion excitations were applied to both fixed‐base and seismically isolated structure models representative of short‐ and long‐period structures, respectively. Results revealed that both the amplitudes of scale factors and seismic response of short‐period structures are more prone to variation of investigated parameters compared to those of long‐period structures.
- 1 November 2019
- Published by Wiley in Earthquake Spectra
- Vol. 35 (4) , 1663-1688
Significance of Ground Motion Scaling Parameters on Amplitude of Scale Factors and Seismic Response of Short‐ and Long‐Period Structures
In this study, an ensemble of ground motions is selected and scaled in order to perform code‐compliant bidirectional Nonlinear Response History Analysis for the design purpose of both short‐ and long‐period structures. The followed scaling method provides both the requirements of the Turkish Earthquake Code regarding the scaling of ground motions and compatibility of response spectra of selected ground motion pairs with the target spectrum. The effects of four parameters, involved in the followed scaling method, on both the amplitude of scale factors and seismic response of structures are investigated. These parameters are the number of ground motion records, period range, number of periods used in the related period range, and distribution of weight factors at the selected periods. In the analyses, ground motion excitations were applied to both fixed‐base and seismically isolated structure models representative of short‐ and long‐period structures, respectively. Results revealed that both the amplitudes of scale factors and seismic response of short‐period structures are more prone to variation of investigated parameters compared to those of long‐period structures.
- 1 August 2014
- Published by Springer Nature in Earthquake Engineering and Engineering Vibration
- Vol. 13 (1) , 79-94
Persisting challenges for performance-based building assessment
- 1 August 2014
- Published by Springer Nature in Earthquake Engineering and Engineering Vibration
- Vol. 13 (1) , 79-94
Persisting challenges for performance-based building assessment
- 25 October 2013
- Published by Techno-Press in STRUCTURAL ENGINEERING AND MECHANICS
- Vol. 48 (2) , 151-171
Numerical simulation of shaking table tests on 3D reinforced concrete structures
- 25 October 2013
- Published by Techno-Press in STRUCTURAL ENGINEERING AND MECHANICS
- Vol. 48 (2) , 151-171
Numerical simulation of shaking table tests on 3D reinforced concrete structures
- 1 August 2011
- Published by Wiley in Earthquake Spectra
- Vol. 27 (3) , 635-659
Buildings Subjected to Recurring Earthquakes: A Tale of Three Cities
Three different buildings built according to the same design have experienced three different near‐field strong ground motions over a period of 11 years in three different cities in Turkey. The input motion was known for each because strong‐motion sensors were located adjacent or close to the buildings. We examine the performance of the five‐story, reinforced concrete‐frame buildings. Bidirectional nonlinear time history and nonlinear static analyses on 3‐D analytical models are performed. The principal focus is to assess whether the analytical model of the buildings could indicate column‐beam damage consistent with that observed at the sites after the earthquakes. Results illustrate that nonlinear time history analyses are capable of indicating the occurrence of shear failure in captive columns; however, they overestimate the global damage. The overestimation is greater where the building sustained a pulse‐type motion without significant distress. It appears that difference between visual observations and analytical results persists.
- 1 August 2011
- Published by Wiley in Earthquake Spectra
- Vol. 27 (3) , 635-659
Buildings Subjected to Recurring Earthquakes: A Tale of Three Cities
Three different buildings built according to the same design have experienced three different near‐field strong ground motions over a period of 11 years in three different cities in Turkey. The input motion was known for each because strong‐motion sensors were located adjacent or close to the buildings. We examine the performance of the five‐story, reinforced concrete‐frame buildings. Bidirectional nonlinear time history and nonlinear static analyses on 3‐D analytical models are performed. The principal focus is to assess whether the analytical model of the buildings could indicate column‐beam damage consistent with that observed at the sites after the earthquakes. Results illustrate that nonlinear time history analyses are capable of indicating the occurrence of shear failure in captive columns; however, they overestimate the global damage. The overestimation is greater where the building sustained a pulse‐type motion without significant distress. It appears that difference between visual observations and analytical results persists.
- 1 July 2011
- Published by Elsevier in Soil Dynamics and Earthquake Engineering
- Vol. 31 (7) , 921-929
Change in response of bridges isolated with LRBs due to lead core heating
- 1 July 2011
- Published by Elsevier in Soil Dynamics and Earthquake Engineering
- Vol. 31 (7) , 921-929
Change in response of bridges isolated with LRBs due to lead core heating