Deniz Birlik Kayı
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Deniz Birlik Kayı has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Beyhan Bayhan
Earthquake Engineering Research Center, Bursa Technical University, Bursa 16310, Türkiye
2 shared publications - Gökhan Özdemi̇r
Department of Civil Engineering, Bursa Technical University, Bursa 16310, Türkiye
2 shared publications
Latest Publications
- Open Access
- 28 April 2026
- Published by Springer Nature in Bulletin of Earthquake Engineering
- p. 1-29
Effect of superstructure characteristics on seismic response of an RC building retrofitted with lead rubber bearings
This paper investigates the change in seismic demands of a reinforced concrete (RC) building retrofitted by seismic isolation technique, due to change in superstructure characteristics. First, an RC building that possesses the general characteristics of fixed-base building stock in Türkiye is identified. Then, it is retrofitted by means of Lead Rubber Bearings (LRBs) and subjected to bidirectional ground motion excitations through nonlinear response history analyses (NRHA). Concrete compressive strength, dimensions of both beams and columns, and first story height are the parameters considered in the analyses. Two different numerical models are established by considering both linear and nonlinear element definitions for the superstructure. In either case, LRBs are represented by deteriorating hysteretic force-displacement relations that consider the effect of heating in the lead core during cyclic motion. Results indicate that increasing the beam dimensions is the most effective approach in retrofitting of the analyzed structural model to reduce inter-story drift ratios (ISDRs). An increase in beam dimensions led to an approximately 30% reduction in ISDRs, while enhancements in concrete compressive strength and dimensions of columns yielded reductions of nearly 20%. The elastic superstructure model may lead to underestimated ISDRs by more than 1.5 folds compared to its nonlinear counterpart.
- 28 April 2026
- Published by Springer Nature in Bulletin of Earthquake Engineering
- p. 1-29
Open AccessEffect of superstructure characteristics on seismic response of an RC building retrofitted with lead rubber bearings
This paper investigates the change in seismic demands of a reinforced concrete (RC) building retrofitted by seismic isolation technique, due to change in superstructure characteristics. First, an RC building that possesses the general characteristics of fixed-base building stock in Türkiye is identified. Then, it is retrofitted by means of Lead Rubber Bearings (LRBs) and subjected to bidirectional ground motion excitations through nonlinear response history analyses (NRHA). Concrete compressive strength, dimensions of both beams and columns, and first story height are the parameters considered in the analyses. Two different numerical models are established by considering both linear and nonlinear element definitions for the superstructure. In either case, LRBs are represented by deteriorating hysteretic force-displacement relations that consider the effect of heating in the lead core during cyclic motion. Results indicate that increasing the beam dimensions is the most effective approach in retrofitting of the analyzed structural model to reduce inter-story drift ratios (ISDRs). An increase in beam dimensions led to an approximately 30% reduction in ISDRs, while enhancements in concrete compressive strength and dimensions of columns yielded reductions of nearly 20%. The elastic superstructure model may lead to underestimated ISDRs by more than 1.5 folds compared to its nonlinear counterpart.
- Open Access
Effectiveness of Seismic Isolation Technique as a Retrofit Solution in the Case of an RC Building with Corroded Reinforcement
This paper aims to quantify the change in seismic response of a reinforced concrete (RC) building retrofitted by the seismic isolation technique when reinforcement corrosion is considered. In this regard, an 8-story RC building that possesses the characteristics of the existing fixed-base building stock in Türkiye has been identified and hypothetically retrofitted with lead rubber bearings (LRBs). In the numerical models, four different corrosion scenarios to represent the spatial distribution of corrosion on the frame elements of the superstructure and three different corrosion levels considering the mass losses (5, 10 and 20%) due to corrosion are considered; the corresponding reductions in (i) the cross-sectional areas of both the longitudinal and transverse reinforcements and (ii) the mechanical properties of steel and concrete are taken into account. Code-based bidirectional nonlinear response history analyses (NRHAs) are performed by considering the nonlinearity not only in the seismic isolation system but also in the superstructure. Furthermore, LRBs are represented by a force–displacement relation that enables modeling of the deterioration in strength of isolators due to lead core heating during cyclic motion. The results revealed that the spatial distribution of the corrosion is highly effective in amplification of inter-story drift ratios (ISDRs), which can be in the order of 2-fold depending on the level of mass loss. It is found that the seismic isolation technique is still effective in protecting the superstructure against earthquakes even though there is a corrosion problem in frame members.
Open AccessEffectiveness of Seismic Isolation Technique as a Retrofit Solution in the Case of an RC Building with Corroded Reinforcement
This paper aims to quantify the change in seismic response of a reinforced concrete (RC) building retrofitted by the seismic isolation technique when reinforcement corrosion is considered. In this regard, an 8-story RC building that possesses the characteristics of the existing fixed-base building stock in Türkiye has been identified and hypothetically retrofitted with lead rubber bearings (LRBs). In the numerical models, four different corrosion scenarios to represent the spatial distribution of corrosion on the frame elements of the superstructure and three different corrosion levels considering the mass losses (5, 10 and 20%) due to corrosion are considered; the corresponding reductions in (i) the cross-sectional areas of both the longitudinal and transverse reinforcements and (ii) the mechanical properties of steel and concrete are taken into account. Code-based bidirectional nonlinear response history analyses (NRHAs) are performed by considering the nonlinearity not only in the seismic isolation system but also in the superstructure. Furthermore, LRBs are represented by a force–displacement relation that enables modeling of the deterioration in strength of isolators due to lead core heating during cyclic motion. The results revealed that the spatial distribution of the corrosion is highly effective in amplification of inter-story drift ratios (ISDRs), which can be in the order of 2-fold depending on the level of mass loss. It is found that the seismic isolation technique is still effective in protecting the superstructure against earthquakes even though there is a corrosion problem in frame members.