Chai Hong Yeong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chai Hong Yeong has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Basri Johan Jeet Abdullah
University of Malaya Research Imaging Centre and Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia
3 shared publications- Alan Christopher Perkins
Radiological Sciences, School of Medicine, University of Nottingham, Nottingham, UK
2 shared publications - Anatoly B. Rosenfeld
Centre for Medical Radiation Physics, University of Wollongong
2 shared publications - Kwan Hoong Ng
Universiti Malaya
2 shared publications Kwan-Hoong Ng
University of Malaya
2 shared publications- Nurul Ab. Aziz Hashikin
Univ Sains Malaysia, Sch Phys, George Town 11800, Malaysia
2 shared publications
Latest Publications
- 20 October 2017
- Published by SAGE Publications in Journal of Diagnostic Medical Sonography
- Vol. 33 (6) , 481-488
Elasticity Characterization of Liver Cancers Using Shear Wave Ultrasound Elastography: Comparison Between Hepatocellular Carcinoma and Liver Metastasis
Purpose: This was a feasibility study of shear wave ultrasound elastography for characterization of liver tumors and to compare the tissue elasticity values of hepatocellular carcinoma (HCC), liver metastases, and normal liver tissues.Methods: Forty-one patients and 30 healthy volunteers were recruited and categorized into HCC, liver metastasis, and control groups based on their computed tomography and sonographic examinations. Elasticity values of different groups were compared statistically.Results: Mean (standard deviation) elasticity values for HCC, liver metastasis, and normal liver tissue were 51.45 (14.96), 49.89 (13.82), and 6.63 (1.65) kilopascal, respectively. Statistically significant differences were found between the elasticity values of HCC and liver metastasis with normal liver tissue. Based on the receiver operating characteristics analysis, 18.25 kilopascal may differentiate the malignant focal liver lesions from the normal liver tissue with both sensitivity and specificity of 100%.Conclusion: Shear wave ultrasound elastography may be able to differentiate HCC and liver metastasis from normal liver tissue based on the tissue elasticity values.
- 20 October 2017
- Published by SAGE Publications in Journal of Diagnostic Medical Sonography
- Vol. 33 (6) , 481-488
Elasticity Characterization of Liver Cancers Using Shear Wave Ultrasound Elastography: Comparison Between Hepatocellular Carcinoma and Liver Metastasis
Purpose: This was a feasibility study of shear wave ultrasound elastography for characterization of liver tumors and to compare the tissue elasticity values of hepatocellular carcinoma (HCC), liver metastases, and normal liver tissues.Methods: Forty-one patients and 30 healthy volunteers were recruited and categorized into HCC, liver metastasis, and control groups based on their computed tomography and sonographic examinations. Elasticity values of different groups were compared statistically.Results: Mean (standard deviation) elasticity values for HCC, liver metastasis, and normal liver tissue were 51.45 (14.96), 49.89 (13.82), and 6.63 (1.65) kilopascal, respectively. Statistically significant differences were found between the elasticity values of HCC and liver metastasis with normal liver tissue. Based on the receiver operating characteristics analysis, 18.25 kilopascal may differentiate the malignant focal liver lesions from the normal liver tissue with both sensitivity and specificity of 100%.Conclusion: Shear wave ultrasound elastography may be able to differentiate HCC and liver metastasis from normal liver tissue based on the tissue elasticity values.
- 22 August 2017
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (18) , 7342-7356
Systematic investigation on the validity of partition model dosimetry for 90 Y radioembolization using Monte Carlo simulation
We aimed to investigate the validity of the partition model (PM) in estimating the absorbed doses to liver tumour ( D T ), normal liver tissue ( D N L ) and lungs ( D L ), when cross-fire irradiations between these compartments are being considered. MIRD-5 phantom incorporated with various treatment parameters, i.e. tumour involvement (TI), tumour-to-normal liver uptake ratio (T/N) and lung shunting (LS), were simulated using the Geant4 Monte Carlo (MC) toolkit. 10 8 track histories were generated for each combination of the three parameters to obtain the absorbed dose per activity uptake in each compartment ( D T A T , D N L A N L , and D L A L ). The administered activities, A were estimated using PM, so as to achieve either limiting doses to normal liver, D N L l i m or lungs, D L l i m (70 or 30 Gy, respectively). Using these administered activities, the activity uptake in each compartment ( A T , A N L , and A L ) was estimated and multiplied with the absorbed dose per activity uptake attained using the MC simulations, to obtain the actual dose received by each compartment. PM overestimated D L by 11.7% in all cases, due to the escaped particles from the lungs. D T and D N L by MC were largely affected by T/N, which were not considered by PM due to cross-fire exclusion at the tumour-normal liver boundary. These have resulted in the overestimation of D T by up to 8% and underestimation of D N L by as high as −78%, by PM. When D N L l i m was estimated via PM, the MC simulations showed significantly higher D N L for cases with higher T/N, and LS ⩽ 10%. All D L and D T by MC were overestimated by PM, thus D L l i m were never exceeded. PM leads to inaccurate dose estimations due to the exclusion of cross-fire irradiation, i.e. between the tumour and normal liver tissue. Caution should be taken for cases with higher TI and T/N, and lower LS, as they contribute to major underestimation of D N L . For D L , a different correction factor for dose calculation may be used for improved accuracy.
- 22 August 2017
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (18) , 7342-7356
Systematic investigation on the validity of partition model dosimetry for 90 Y radioembolization using Monte Carlo simulation
We aimed to investigate the validity of the partition model (PM) in estimating the absorbed doses to liver tumour ( D T ), normal liver tissue ( D N L ) and lungs ( D L ), when cross-fire irradiations between these compartments are being considered. MIRD-5 phantom incorporated with various treatment parameters, i.e. tumour involvement (TI), tumour-to-normal liver uptake ratio (T/N) and lung shunting (LS), were simulated using the Geant4 Monte Carlo (MC) toolkit. 10 8 track histories were generated for each combination of the three parameters to obtain the absorbed dose per activity uptake in each compartment ( D T A T , D N L A N L , and D L A L ). The administered activities, A were estimated using PM, so as to achieve either limiting doses to normal liver, D N L l i m or lungs, D L l i m (70 or 30 Gy, respectively). Using these administered activities, the activity uptake in each compartment ( A T , A N L , and A L ) was estimated and multiplied with the absorbed dose per activity uptake attained using the MC simulations, to obtain the actual dose received by each compartment. PM overestimated D L by 11.7% in all cases, due to the escaped particles from the lungs. D T and D N L by MC were largely affected by T/N, which were not considered by PM due to cross-fire exclusion at the tumour-normal liver boundary. These have resulted in the overestimation of D T by up to 8% and underestimation of D N L by as high as −78%, by PM. When D N L l i m was estimated via PM, the MC simulations showed significantly higher D N L for cases with higher T/N, and LS ⩽ 10%. All D L and D T by MC were overestimated by PM, thus D L l i m were never exceeded. PM leads to inaccurate dose estimations due to the exclusion of cross-fire irradiation, i.e. between the tumour and normal liver tissue. Caution should be taken for cases with higher TI and T/N, and lower LS, as they contribute to major underestimation of D N L . For D L , a different correction factor for dose calculation may be used for improved accuracy.
- 14 June 2017
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 27 (2) , 81-89
Optimal approach for complete liver tumor ablation using radiofrequency ablation: a simulation study
Purpose: To investigate the effect of radiofrequency ablation (RFA) electrode trajectory on complete tumor ablation using computational simulation. Material and methods: The RFA of a spherical tumor of 2.0cm diameter along with 0.5cm clinical safety margin was simulated using Finite Element Analysis software. A total of 86 points inside one-eighth of the tumor volume along the axial, sagittal and coronal planes were selected as the target sites for electrode-tip placement. The angle of the electrode insertion in both craniocaudal and orbital planes ranged from -90 degrees to +90 degrees with 30 degrees increment. The RFA electrode was simulated to pass through the target site at different angles in combination of both craniocaudal and orbital planes before being advanced to the edge of the tumor. Results: Complete tumor ablation was observed whenever the electrode-tip penetrated through the epicenter of the tumor regardless of the angles of electrode insertion in both craniocaudal and orbital planes. Complete tumor ablation can also be achieved by placing the electrode-tip at several optimal sites and angles. Conclusions: Identification of the tumor epicenter on the central slice of the axial images is essential to enhance the success rate of complete tumor ablation during RFA procedures.
- 14 June 2017
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 27 (2) , 81-89
Optimal approach for complete liver tumor ablation using radiofrequency ablation: a simulation study
Purpose: To investigate the effect of radiofrequency ablation (RFA) electrode trajectory on complete tumor ablation using computational simulation. Material and methods: The RFA of a spherical tumor of 2.0cm diameter along with 0.5cm clinical safety margin was simulated using Finite Element Analysis software. A total of 86 points inside one-eighth of the tumor volume along the axial, sagittal and coronal planes were selected as the target sites for electrode-tip placement. The angle of the electrode insertion in both craniocaudal and orbital planes ranged from -90 degrees to +90 degrees with 30 degrees increment. The RFA electrode was simulated to pass through the target site at different angles in combination of both craniocaudal and orbital planes before being advanced to the edge of the tumor. Results: Complete tumor ablation was observed whenever the electrode-tip penetrated through the epicenter of the tumor regardless of the angles of electrode insertion in both craniocaudal and orbital planes. Complete tumor ablation can also be achieved by placing the electrode-tip at several optimal sites and angles. Conclusions: Identification of the tumor epicenter on the central slice of the axial images is essential to enhance the success rate of complete tumor ablation during RFA procedures.
- 1 March 2017
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 33, 400-410
Data mining framework for breast lesion classification in shear wave ultrasound: A hybrid feature paradigm
- 1 March 2017
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 33, 400-410
Data mining framework for breast lesion classification in shear wave ultrasound: A hybrid feature paradigm
- Open Access
- 23 March 2016
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 694 (1) , 012059
Organ doses from hepatic radioembolization with90Y,153Sm,166Ho and177Lu: A Monte Carlo simulation study using Geant4
90Y-radioembolization is a palliative treatment for liver cancer. 90Y decays via beta emission, making imaging difficult due to absence of gamma radiation. Since post-procedure imaging is crucial, several theranostic radionuclides have been explored as alternatives. However, exposures to gamma radiation throughout the treatment caused concern for the organs near the liver. Geant4 Monte Carlo simulation using MIRD Pamphlet 5 reference phantom was carried out. A spherical tumour with 4.3cm radius was modelled within the liver. 1.82GBq of 90Y sources were isotropically distributed within the tumour, with no extrahepatic shunting. The simulation was repeated with 153Sm, 166Ho and 177Lu. The estimated tumour doses for all radionuclides were 262.9Gy. Tumour dose equivalent to 1.82GBq 90Y can be achieved with 8.32, 5.83, and 4.44GBq for 153Sm, 166Ho and 177Lu, respectively. Normal liver doses by the other radionuclides were lower than 90Y, hence beneficial for normal tissue sparing. The organ doses from 153Sm and 177Lu were relatively higher due to higher gamma energy, but were still well below 1Gy. 166Ho, 177Lu and 153Sm offer useful gamma emission for post-procedure imaging. They show potential as 90Y substitutes, delivering comparable tumour doses, lower normal liver doses and other organs doses far below the tolerance limit.
- 23 March 2016
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 694 (1) , 012059
Open AccessOrgan doses from hepatic radioembolization with90Y,153Sm,166Ho and177Lu: A Monte Carlo simulation study using Geant4
90Y-radioembolization is a palliative treatment for liver cancer. 90Y decays via beta emission, making imaging difficult due to absence of gamma radiation. Since post-procedure imaging is crucial, several theranostic radionuclides have been explored as alternatives. However, exposures to gamma radiation throughout the treatment caused concern for the organs near the liver. Geant4 Monte Carlo simulation using MIRD Pamphlet 5 reference phantom was carried out. A spherical tumour with 4.3cm radius was modelled within the liver. 1.82GBq of 90Y sources were isotropically distributed within the tumour, with no extrahepatic shunting. The simulation was repeated with 153Sm, 166Ho and 177Lu. The estimated tumour doses for all radionuclides were 262.9Gy. Tumour dose equivalent to 1.82GBq 90Y can be achieved with 8.32, 5.83, and 4.44GBq for 153Sm, 166Ho and 177Lu, respectively. Normal liver doses by the other radionuclides were lower than 90Y, hence beneficial for normal tissue sparing. The organ doses from 153Sm and 177Lu were relatively higher due to higher gamma energy, but were still well below 1Gy. 166Ho, 177Lu and 153Sm offer useful gamma emission for post-procedure imaging. They show potential as 90Y substitutes, delivering comparable tumour doses, lower normal liver doses and other organs doses far below the tolerance limit.
- Top Cited Papers
- 16 October 2014
- Published by Zhejiang University Press in Journal of Zhejiang University-SCIENCE B
- Vol. 15 (10) , 845-863
Therapeutic radionuclides in nuclear medicine: current and future prospects
The potential use of radionuclides in therapy has been recognized for many decades. A number of radionuclides, such as iodine-131 (131I), phosphorous-32 (32P), strontium-90 (90Sr), and yttrium-90 (90Y), have been used successfully for the treatment of many benign and malignant disorders. Recently, the rapid growth of this branch of nuclear medicine has been stimulated by the introduction of a number of new radionuclides and radiopharmaceuticals for the treatment of metastatic bone pain and neuroendocrine and other malignant or non-malignant tumours. Today, the field of radionuclide therapy is enjoying an exciting phase and is poised for greater growth and development in the coming years. For example, in Asia, the high prevalence of thyroid and liver diseases has prompted many novel developments and clinical trials using targeted radionuclide therapy. This paper reviews the characteristics and clinical applications of the commonly available therapeutic radionuclides, as well as the problems and issues involved in translating novel radionuclides into clinical therapies. 本文综述了临床常用的放射性治疗方式和应用现状以及新的放射性核素从科研至临床应用所存在的问题。 放射性核素的临床应用及研究已历数十载, 已有碘-131、 磷-32、 锶-90 及钇-90 等众多放射性核素被成功用于治疗良恶性疾病。随着新的放射性核素及药物不断应用于骨转移瘤疼痛治疗、 神经内分泌肿瘤及其他良恶性肿瘤治疗, 放射性核素治疗得到了快速发展。 目前, 放射性核素治疗已进入蓬勃发展期; 在亚洲, 由于甲状腺和肝脏肿瘤的高发病率, 促进了放射性核素治疗及其靶向治疗研究的日益发展。 随着放射性核素与其他药物的联合应用, 放射性核素治疗肿瘤的临床价值必将显著提高。
- 16 October 2014
- Published by Zhejiang University Press in Journal of Zhejiang University-SCIENCE B
- Vol. 15 (10) , 845-863
Top Cited PapersTherapeutic radionuclides in nuclear medicine: current and future prospects
The potential use of radionuclides in therapy has been recognized for many decades. A number of radionuclides, such as iodine-131 (131I), phosphorous-32 (32P), strontium-90 (90Sr), and yttrium-90 (90Y), have been used successfully for the treatment of many benign and malignant disorders. Recently, the rapid growth of this branch of nuclear medicine has been stimulated by the introduction of a number of new radionuclides and radiopharmaceuticals for the treatment of metastatic bone pain and neuroendocrine and other malignant or non-malignant tumours. Today, the field of radionuclide therapy is enjoying an exciting phase and is poised for greater growth and development in the coming years. For example, in Asia, the high prevalence of thyroid and liver diseases has prompted many novel developments and clinical trials using targeted radionuclide therapy. This paper reviews the characteristics and clinical applications of the commonly available therapeutic radionuclides, as well as the problems and issues involved in translating novel radionuclides into clinical therapies. 本文综述了临床常用的放射性治疗方式和应用现状以及新的放射性核素从科研至临床应用所存在的问题。 放射性核素的临床应用及研究已历数十载, 已有碘-131、 磷-32、 锶-90 及钇-90 等众多放射性核素被成功用于治疗良恶性疾病。随着新的放射性核素及药物不断应用于骨转移瘤疼痛治疗、 神经内分泌肿瘤及其他良恶性肿瘤治疗, 放射性核素治疗得到了快速发展。 目前, 放射性核素治疗已进入蓬勃发展期; 在亚洲, 由于甲状腺和肝脏肿瘤的高发病率, 促进了放射性核素治疗及其靶向治疗研究的日益发展。 随着放射性核素与其他药物的联合应用, 放射性核素治疗肿瘤的临床价值必将显著提高。
- 1 July 2013
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 34 (7) , 645-651
Fusion of gamma scintigraphic and magnetic resonance images improves the anatomical delineation of radiotracer for the assessment of gastrointestinal transit
This paper describes the use of gamma scintigraphic and magnetic resonance (MR) fusion images for improving the anatomical delineation of orally administered radiotracers used in gastrointestinal (GI) transit investigations. Ten healthy volunteers ingested enteric-coated gelatin capsules containing 4.4 ± 1.1 MBq SmCl3-labelled resin. Four external body markers containing Sm and Gd-DTPA were placed on the left and right lower costal margins and iliac crests of each volunteer. Anterior and posterior planar images were acquired hourly for 9 h, followed by a final single photon emission computed tomography (SPECT) image and subsequent T1-weighted images using a 1.5 T MR system. Coronal scintigraphic images were fused with MR images and assessed for diagnostic information. The fused images revealed a combination of the tissue and organ anatomy with an overlay of the distribution of the tracer. Compared with conventional scintigraphic imaging alone, SPECT-MR fused images improved the localization of spatial and temporal movements of the radiotracer throughout the GI tract. Fusion of SPECT and MR images in conjunction with sequential scintigraphic images improved the assessment of segmental GI transit. These have the potential to provide more accurate diagnostic results and are visually powerful images that would have more widespread acceptance by nonspecialists.
- 1 July 2013
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 34 (7) , 645-651
Fusion of gamma scintigraphic and magnetic resonance images improves the anatomical delineation of radiotracer for the assessment of gastrointestinal transit
This paper describes the use of gamma scintigraphic and magnetic resonance (MR) fusion images for improving the anatomical delineation of orally administered radiotracers used in gastrointestinal (GI) transit investigations. Ten healthy volunteers ingested enteric-coated gelatin capsules containing 4.4 ± 1.1 MBq SmCl3-labelled resin. Four external body markers containing Sm and Gd-DTPA were placed on the left and right lower costal margins and iliac crests of each volunteer. Anterior and posterior planar images were acquired hourly for 9 h, followed by a final single photon emission computed tomography (SPECT) image and subsequent T1-weighted images using a 1.5 T MR system. Coronal scintigraphic images were fused with MR images and assessed for diagnostic information. The fused images revealed a combination of the tissue and organ anatomy with an overlay of the distribution of the tracer. Compared with conventional scintigraphic imaging alone, SPECT-MR fused images improved the localization of spatial and temporal movements of the radiotracer throughout the GI tract. Fusion of SPECT and MR images in conjunction with sequential scintigraphic images improved the assessment of segmental GI transit. These have the potential to provide more accurate diagnostic results and are visually powerful images that would have more widespread acceptance by nonspecialists.