Rajinikumar Ramalingam
Research Interests
Rajinikumar Ramalingam has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
H Neumann
Institute of Technical Physics, 76344 Eggenstein-Leopoldshafen, Germany
2 shared publicationsH. Neumann
Institute for Technical Physics, Karlsruhe Institute of Technology, Germany
2 shared publicationsF Araujo
FiberSensing, Rua Vasconcelos Costa 277, 4470-640 Maia, Portugal
1 shared publicationHolger Neumann
Karlsruhe Institute of Technology (KIT)
1 shared publicationJ Araujo
Department of Physics and Astronomy, University of Porto, 4099-002 Porto, Portugal
1 shared publicationJ Sun
Institute of Technical Physics, 76344 Eggenstein-Leopoldshafen, Germany
1 shared publication
Latest Publications
- Open Access
- 15 April 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 502 (1) , 012169
Design and Implementation of the Instrumentation and Sensor System for testing of a sub modelled 10 MW offshore superconducting wind turbine.
The large head mass of an offshore wind turbine can be reduced by using superconducting technology. As a proof of concept, a superconducting 10 MW wind turbine for offshore application is investigated under the SUPRAPOWER project funded by EU-FP7. SC coils were developed using MgB2 tapes and cooled to 20 K by a two stage Gifford McMahon cryocooler in a modular rotating cryostat. To study the coil performance and to measure and control the sub model, a LABVIEW based instrumentation system is developed. To measure the temperature distribution in a rotating cryostat, an optical based sensing system is designed and introduced. The effect of rotation on an optical based sensing system is studied. In this paper, the instrumentation along with the thermal characteristics and validation of the optical sensing system for rotating machines and its installation techniques will be reported.
- 15 April 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 502 (1) , 012169
Open AccessDesign and Implementation of the Instrumentation and Sensor System for testing of a sub modelled 10 MW offshore superconducting wind turbine.
The large head mass of an offshore wind turbine can be reduced by using superconducting technology. As a proof of concept, a superconducting 10 MW wind turbine for offshore application is investigated under the SUPRAPOWER project funded by EU-FP7. SC coils were developed using MgB2 tapes and cooled to 20 K by a two stage Gifford McMahon cryocooler in a modular rotating cryostat. To study the coil performance and to measure and control the sub model, a LABVIEW based instrumentation system is developed. To measure the temperature distribution in a rotating cryostat, an optical based sensing system is designed and introduced. The effect of rotation on an optical based sensing system is studied. In this paper, the instrumentation along with the thermal characteristics and validation of the optical sensing system for rotating machines and its installation techniques will be reported.
- Open Access
- 28 February 2017
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 171 (1) , 012133
Numerical and experimental investigation of FBG strain response at cryogenic temperatures
Strain response of FBG sensors are investigated at various temperatures from 298 K to 4.2 K. Numerical modelling is carried out for acrylate coated, substrate-free fiber Bragg grating (FBG) sensors at room temperature of 298 K and cryogenic temperatures of 77 K, 10 K and 4.2 K. A 1550 nm Bragg wavelength (λB) FBG sensor is modelled and simulated for applied strain (ε) ranging from 0 to 800 µm/m. The Bragg wavelength shifts (ΔλB) thus obtained are compared with the experimentally investigated values obtained by subjecting the FBG sensor to axial strain, with its sensing part not being bonded to any surface. The MTS25 tensile machine with a cryostat under vacuum conditions (10-4 mbar pressure) is used for the experiments and the required temperatures are maintained using liquid Nitrogen (LN2) and compressed Helium gas (He). The Bragg wavelength shift (ΔλB) versus induced strain (ε) is regressed with a linear polynomial function and the strain sensitivity obtained in both the cases are discussed.
- 28 February 2017
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 171 (1) , 012133
Open AccessNumerical and experimental investigation of FBG strain response at cryogenic temperatures
Strain response of FBG sensors are investigated at various temperatures from 298 K to 4.2 K. Numerical modelling is carried out for acrylate coated, substrate-free fiber Bragg grating (FBG) sensors at room temperature of 298 K and cryogenic temperatures of 77 K, 10 K and 4.2 K. A 1550 nm Bragg wavelength (λB) FBG sensor is modelled and simulated for applied strain (ε) ranging from 0 to 800 µm/m. The Bragg wavelength shifts (ΔλB) thus obtained are compared with the experimentally investigated values obtained by subjecting the FBG sensor to axial strain, with its sensing part not being bonded to any surface. The MTS25 tensile machine with a cryostat under vacuum conditions (10-4 mbar pressure) is used for the experiments and the required temperatures are maintained using liquid Nitrogen (LN2) and compressed Helium gas (He). The Bragg wavelength shift (ΔλB) versus induced strain (ε) is regressed with a linear polynomial function and the strain sensitivity obtained in both the cases are discussed.
- Open Access
- 28 February 2017
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 171 (1) , 012136
Experimental investigation on mass flow rate measurements using fibre Bragg grating sensors
Flow measurement and control of cryogens is one of the major requirements of systems such as superconductor magnets for fusion reactors, MRI magnets etc. They can act as an early diagnostic tool for detection of any faults and ensure correct distribution of cooling load while also accessing thermal performance of the devices. Fibre Bragg Grating (FBG) sensors provide compact and accurate measurement systems which have added advantages such as immunity towards electrical and magnetic interference, low attenuation losses and remote sensing. This paper summarizes the initial experimental investigations and calibration of a novel FBG based mass flow meter. This design utilizes the viscous drag due to the flow to induce a bending strain on the fibre. The strain experienced by the fibre will be proportional to the flowrate and can be measured in terms of Bragg wavelength shift. The flowmeter is initially tested at atmospheric conditions using helium. The results are summarized and the performance parameters of the sensor are estimated. The results were also compared to a numerical model and further results for liquid helium is also reported. An overall sensitivity of 29 pm.(g.s-1)-1 was obtained for a helium flow, with a resolution of 0.2 g.s-1. A hysteresis error of 8 pm was also observed during load-unload cycles. The sensor is suitable for further tests using cryogens.
- 28 February 2017
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 171 (1) , 012136
Open AccessExperimental investigation on mass flow rate measurements using fibre Bragg grating sensors
Flow measurement and control of cryogens is one of the major requirements of systems such as superconductor magnets for fusion reactors, MRI magnets etc. They can act as an early diagnostic tool for detection of any faults and ensure correct distribution of cooling load while also accessing thermal performance of the devices. Fibre Bragg Grating (FBG) sensors provide compact and accurate measurement systems which have added advantages such as immunity towards electrical and magnetic interference, low attenuation losses and remote sensing. This paper summarizes the initial experimental investigations and calibration of a novel FBG based mass flow meter. This design utilizes the viscous drag due to the flow to induce a bending strain on the fibre. The strain experienced by the fibre will be proportional to the flowrate and can be measured in terms of Bragg wavelength shift. The flowmeter is initially tested at atmospheric conditions using helium. The results are summarized and the performance parameters of the sensor are estimated. The results were also compared to a numerical model and further results for liquid helium is also reported. An overall sensitivity of 29 pm.(g.s-1)-1 was obtained for a helium flow, with a resolution of 0.2 g.s-1. A hysteresis error of 8 pm was also observed during load-unload cycles. The sensor is suitable for further tests using cryogens.
- 18 November 2016
- Published by Springer Nature
- p. 191-202
Strain Calibration of Substrate-Free FBG Sensors at Cryogenic Temperature
- 18 November 2016
- Published by Springer Nature
- p. 191-202
Strain Calibration of Substrate-Free FBG Sensors at Cryogenic Temperature
- 3 August 2016
- Published by Springer Nature in Journal of Superconductivity and Novel Magnetism
- Vol. 30 (7) , 1963-1970
Strain Characterization of HighTemperature Superconductor Tapes Using Embedded Fibre Bragg Grating Sensor in Mid-rip and Parallel Configuration
- 3 August 2016
- Published by Springer Nature in Journal of Superconductivity and Novel Magnetism
- Vol. 30 (7) , 1963-1970
Strain Characterization of HighTemperature Superconductor Tapes Using Embedded Fibre Bragg Grating Sensor in Mid-rip and Parallel Configuration
- Open Access
- 18 December 2015
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 101 (1) , 012154
A study on intermediate buffer layer of coated Fiber Bragg Grating cryogenic temperature sensors
The sensor characteristics of a coated Fiber Bragg grating (FBG) thermal sensor for cryogenic temperatures depends mainly on the coating materials. The sensitivity of the coated FBG can be improved by enhancing the effective thermal strain transfer between the different layers and the bare FBG. The dual coated FBG's has a primary layer and the secondary layer. The primary coating acts as an intermediate buffer between the secondary coating and the bare FBG. The outer secondary coating is normally made of metals with high thermal expansion coefficient. In this work, a detailed study is carried out on chromium and titanium intermediate buffer layers with various coating thicknesses and combinations. To improve the sensitivity, the secondary coating layer was tested with Indium, Lead and Tin. The sensors were then calibrated in a cryogenic temperature calibration facility at Institute of Technical Physics (ITEP), Karlsruhe Institute of Technology. The sensors were subjected to several thermal cycles between 4.2 and 80 K to study the sensor performance and its thermal characteristics. The sensor exhibits a Bragg wavelength shift of 13pm at 20K. The commercially available detection equipment with a resolution of 1pm can result in a temperature resolution of 0.076 K at 20K.
- 18 December 2015
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 101 (1) , 012154
Open AccessA study on intermediate buffer layer of coated Fiber Bragg Grating cryogenic temperature sensors
The sensor characteristics of a coated Fiber Bragg grating (FBG) thermal sensor for cryogenic temperatures depends mainly on the coating materials. The sensitivity of the coated FBG can be improved by enhancing the effective thermal strain transfer between the different layers and the bare FBG. The dual coated FBG's has a primary layer and the secondary layer. The primary coating acts as an intermediate buffer between the secondary coating and the bare FBG. The outer secondary coating is normally made of metals with high thermal expansion coefficient. In this work, a detailed study is carried out on chromium and titanium intermediate buffer layers with various coating thicknesses and combinations. To improve the sensitivity, the secondary coating layer was tested with Indium, Lead and Tin. The sensors were then calibrated in a cryogenic temperature calibration facility at Institute of Technical Physics (ITEP), Karlsruhe Institute of Technology. The sensors were subjected to several thermal cycles between 4.2 and 80 K to study the sensor performance and its thermal characteristics. The sensor exhibits a Bragg wavelength shift of 13pm at 20K. The commercially available detection equipment with a resolution of 1pm can result in a temperature resolution of 0.076 K at 20K.