Suzan Bsat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Suzan Bsat has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Xiao Huang
Carleton University, Ottawa, ON, Canada
3 shared publications - Amir Abbas Zadpoor
Delft University of Technology
1 shared publication - Andrew D. Speirs
Department of Mechanical and Aerospace Engineering, Carleton University, Ottawa, Ontario, Canada
1 shared publication - Edward R. Valstar
Leiden University Medical Center
1 shared publication Jennifer McTaggart
Carleton University Ottawa K1S 5B6 Canada
1 shared publication- Maximilian Munsch
Implantcast GmbH, Lueneburger Schanze 26, D-21614 Buxtehude, Germany
1 shared publication
Latest Publications
- 20 March 2017
- Published by Wiley in Advanced Engineering Materials
- Vol. 19 (7)
Nano‐Hydroxyapatite and TiO2 Bioactivated Polymer for Implant Applications
Polymers have been successfully used for implant applications, however, challenges remain as their design requires a delicate balance between mechanical, chemical, and physical properties to ensure cell survival and tissue formation. Additive manufacturing techniques, such as SLA, offer the opportunity to achieve desired physical and mechanical properties because of the precision and control over architecture. Such control allows manipulation over the distribution of mechanical properties throughout the implant. PMA/HA and PMA/TiO2 solid and porous structures are, therefore, manufactured using room temperature SLA techniques. HA and TiO2 are added to the polymer for bio‐functionalizing purposes. The apatite forming ability of the samples are evaluated using HBSS immersion. All PMA and PMA/TiO2 samples does not show any bioactivity in terms of apatite formation, although limited amounts of CaO is found on PMA surfaces. PMA/HA samples demonstrate bioactivity with newly formed apatite formation observed after 3 and 5 week HBSS immersion.
- 20 March 2017
- Published by Wiley in Advanced Engineering Materials
- Vol. 19 (7)
Nano‐Hydroxyapatite and TiO2 Bioactivated Polymer for Implant Applications
Polymers have been successfully used for implant applications, however, challenges remain as their design requires a delicate balance between mechanical, chemical, and physical properties to ensure cell survival and tissue formation. Additive manufacturing techniques, such as SLA, offer the opportunity to achieve desired physical and mechanical properties because of the precision and control over architecture. Such control allows manipulation over the distribution of mechanical properties throughout the implant. PMA/HA and PMA/TiO2 solid and porous structures are, therefore, manufactured using room temperature SLA techniques. HA and TiO2 are added to the polymer for bio‐functionalizing purposes. The apatite forming ability of the samples are evaluated using HBSS immersion. All PMA and PMA/TiO2 samples does not show any bioactivity in terms of apatite formation, although limited amounts of CaO is found on PMA surfaces. PMA/HA samples demonstrate bioactivity with newly formed apatite formation observed after 3 and 5 week HBSS immersion.
- 18 July 2016
- Published by Springer Nature in Journal of Thermal Spray Technology
- Vol. 25 (6) , 1088-1110
Recent Trends in Newly Developed Plasma-Sprayed and Sintered Coatings for Implant Applications
- 18 July 2016
- Published by Springer Nature in Journal of Thermal Spray Technology
- Vol. 25 (6) , 1088-1110
Recent Trends in Newly Developed Plasma-Sprayed and Sintered Coatings for Implant Applications
- 14 October 2015
- Published by Springer Nature in Oxidation of Metals
- Vol. 84 (5-6) , 621-631
Corrosion Behaviour 310 Stainless Steel in Superheated Steam
- 14 October 2015
- Published by Springer Nature in Oxidation of Metals
- Vol. 84 (5-6) , 621-631
Corrosion Behaviour 310 Stainless Steel in Superheated Steam
- Open Access
Effect of Alkali-Acid-Heat Chemical Surface Treatment on Electron Beam Melted Porous Titanium and Its Apatite Forming Ability
Advanced additive manufacturing techniques such as electron beam melting (EBM), can produce highly porous structures that resemble the mechanical properties and structure of native bone. However, for orthopaedic applications, such as joint prostheses or bone substitution, the surface must also be bio-functionalized to promote bone growth. In the current work, EBM porous Ti6Al4V alloy was exposed to an alkali acid heat (AlAcH) treatment to bio-functionalize the surface of the porous structure. Various molar concentrations (3, 5, 10M) and immersion times (6, 24 h) of the alkali treatment were used to determine optimal parameters. The apatite forming ability of the samples was evaluated using simulated body fluid (SBF) immersion testing. The micro-topography and surface chemistry of AlAcH treated samples were evaluated before and after SBF testing using scanning electron microscopy and energy dispersive X-ray spectroscopy. The AlAcH treatment successfully modified the topographical and chemical characteristics of EBM porous titanium surface creating nano-topographical features ranging from 200–300 nm in size with a titania layer ideal for apatite formation. After 1 and 3 week immersion in SBF, there was no Ca or P present on the surface of as manufactured porous titanium while both elements were present on all AlAcH treated samples except those exposed to 3M, 6 h alkali treatment. An increase in molar concentration and/or immersion time of alkali treatment resulted in an increase in the number of nano-topographical features per unit area as well as the amount of titania on the surface.
Open AccessEffect of Alkali-Acid-Heat Chemical Surface Treatment on Electron Beam Melted Porous Titanium and Its Apatite Forming Ability
Advanced additive manufacturing techniques such as electron beam melting (EBM), can produce highly porous structures that resemble the mechanical properties and structure of native bone. However, for orthopaedic applications, such as joint prostheses or bone substitution, the surface must also be bio-functionalized to promote bone growth. In the current work, EBM porous Ti6Al4V alloy was exposed to an alkali acid heat (AlAcH) treatment to bio-functionalize the surface of the porous structure. Various molar concentrations (3, 5, 10M) and immersion times (6, 24 h) of the alkali treatment were used to determine optimal parameters. The apatite forming ability of the samples was evaluated using simulated body fluid (SBF) immersion testing. The micro-topography and surface chemistry of AlAcH treated samples were evaluated before and after SBF testing using scanning electron microscopy and energy dispersive X-ray spectroscopy. The AlAcH treatment successfully modified the topographical and chemical characteristics of EBM porous titanium surface creating nano-topographical features ranging from 200–300 nm in size with a titania layer ideal for apatite formation. After 1 and 3 week immersion in SBF, there was no Ca or P present on the surface of as manufactured porous titanium while both elements were present on all AlAcH treated samples except those exposed to 3M, 6 h alkali treatment. An increase in molar concentration and/or immersion time of alkali treatment resulted in an increase in the number of nano-topographical features per unit area as well as the amount of titania on the surface.