Ablation of typical atrial flutter using mini electrode measurements for maximum voltage‐guided ablation: A randomized, controlled trial
Open Access
- 9 December 2021
- journal article
- research article
- Published by Wiley in Journal of Arrhythmia
- Vol. 38 (1) , 106-114
Abstract
Background Novel ablation catheters with mini electrode (ME) sensing have become available but their utility is unclear. We investigated whether ablation of the cavotricuspid isthmus (CTI) for atrial flutter (AFL) would be improved using ME signals. Methods Sixty-one patients (76% male, 63 ± 10 years) with CTI-dependent AFL underwent ablation using a maximum voltage-guided approach, randomized to either standard 8 mm non-irrigated catheter with bipolar signals or IntellaTip MiFi catheter using ME signals alone. Results Acute bidirectional block was achieved in 97%. Mean follow-up was 16.7 ± 10 months. The median number of ablation lesions was 13 in both groups (range 3–62 vs. 1–43, p = .85). No significant differences were observed in AFL recurrences (17% vs. 11%, p = .7), median procedure durations (97 min [interquartile range (IQR), 71–121] vs. 87 min [IQR, 72–107], p = .55) or fluoroscopy times (31 min [IQR, 21–52] vs. 38 min [IQR, 25–70], p = .56). Amplitudes of ME signals were on average 160% greater than blinded bipolar signals. In 23.7% of lesions where bipolar signals were difficult to interpret, 13.6% showed a clear ME signal. Conclusions There was no difference in the effectiveness of CTI ablation guided by ME signals, compared with using bipolar signals from a standard 8 mm ablation catheter. While ME signal amplitudes were larger and sometimes present when the bipolar signal was unclear, this did not improve procedural characteristics or outcomes. The results suggest future research should focus on lesion integrity rather than signal sensing.Keywords
This publication has 20 references indexed in Scilit:
- Importance of anatomy in cavotricuspid isthmusEP Europace, 2016
- Impact of Contact Force Monitoring in Acute Pulmonary Vein Isolation Using an Anatomic Approach. A Randomized StudyPacing and Clinical Electrophysiology, 2016
- Cavotricuspid isthmus ablation using a catheter equipped with mini electrodes on the 8 mm tip: a prospective comparison with an 8 mm dumbbell-shaped tip catheter and 8 mm tip cryothermal catheterEP Europace, 2015
- Randomized, Controlled Trial of the Safety and Effectiveness of a Contact Force–Sensing Irrigated Catheter for Ablation of Paroxysmal Atrial FibrillationCirculation, 2015
- Atrial Flutter — Diagnosis, Management and Treatment2015
- Maximal Electrogram Attenuation Recorded from Mini Electrodes Embedded on 4.5‐mm Irrigated and 8‐mm Nonirrigated Catheters Signifies Lesion MaturationJournal of Cardiovascular Electrophysiology, 2014
- Impact of real-time contact force and impedance measurement in pulmonary vein isolation procedures for treatment of atrial fibrillationClinical Research in Cardiology, 2013
- Reduction in Atrial Flutter Ablation Time by Targeting Maximum Voltage: Results of a Prospective Randomized Clinical TrialJournal of Cardiovascular Electrophysiology, 2009
- Cavotricuspid Isthmus Conduction is Dependent on Underlying Anatomic Bundle Architecture: Observations Using a Maximum Voltage‐Guided Ablation TechniqueJournal of Cardiovascular Electrophysiology, 2006
- Right A trial Flutter Isthmus Revisited:Journal of Cardiovascular Electrophysiology, 2000