Ulisses Chemin Netto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ulisses Chemin Netto has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Adriano Peres de Morais
Federal University of Santa Maria , Santa Maria , Brazil
1 shared publication - André Felipe Silva Melo
Department of Electrical Engineering, University of Seville, Seville, Spain
1 shared publication - Antonio Felipe Da Cunha De Aquino
Department of Electrical Engineering, Federal University of Santa Catarina, Florianópolis, Brazil
1 shared publication Augusto Tietz
1 shared publication- Bryan Almeida Silva Ambrósio1 shared publication
- Daniel Pinheiro Bernardon
Federal University of Santa Maria
1 shared publication
Latest Publications
- Open Access
- 31 July 2026
- Published by Elsevier in SSRN Electronic Journal
Impact of Distributed Photovoltaic Generation on Reverse Power Flow in Radial Networks
Reverse power flow (RPF) from distributed photovoltaic (PV) generation in low-voltage (LV) radial feeders threatens voltage regulation, transformer aging, and unidirectional protection. This paper presents a per-phase time-domain co-simulation platform that couples a procedural network generator, a Markov-chain irradiance model, ComStock/ResStock load profiles, a hybrid prosumer model with behind-the-meter battery storage, and a three-phase pandapower load-flow solver under Mosaik 3. A 432-scenario sweep (3 PV levels × 12 storage capacities × 12 seeds, 30 days at 15 min) shows that PV penetration is the dominant driver of RPF severity: the per-phase inversion time fraction rises from 13.0% to 35.4% as PV scales from 5 to 20 kWh per branch. Behind-the-meter storage is effective at moderate penetration but insufficient at high penetration: even 100 kWh reduces the inversion time fraction by only 29.4% at 20 kW. Root-cause analysis identifies two mechanisms invisible to aggregate steady-state models: households that produce more than they consume on average, and per-phase transformer imbalance. Storage shifts the composition of RPF, absorbing the aggregate surplus while exposing the phase-imbalance floor. Effective RPF elimination, therefore, requires simultaneously addressing both allocation-level and phase-level imbalance.
- 31 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessImpact of Distributed Photovoltaic Generation on Reverse Power Flow in Radial Networks
Reverse power flow (RPF) from distributed photovoltaic (PV) generation in low-voltage (LV) radial feeders threatens voltage regulation, transformer aging, and unidirectional protection. This paper presents a per-phase time-domain co-simulation platform that couples a procedural network generator, a Markov-chain irradiance model, ComStock/ResStock load profiles, a hybrid prosumer model with behind-the-meter battery storage, and a three-phase pandapower load-flow solver under Mosaik 3. A 432-scenario sweep (3 PV levels × 12 storage capacities × 12 seeds, 30 days at 15 min) shows that PV penetration is the dominant driver of RPF severity: the per-phase inversion time fraction rises from 13.0% to 35.4% as PV scales from 5 to 20 kWh per branch. Behind-the-meter storage is effective at moderate penetration but insufficient at high penetration: even 100 kWh reduces the inversion time fraction by only 29.4% at 20 kW. Root-cause analysis identifies two mechanisms invisible to aggregate steady-state models: households that produce more than they consume on average, and per-phase transformer imbalance. Storage shifts the composition of RPF, absorbing the aggregate surplus while exposing the phase-imbalance floor. Effective RPF elimination, therefore, requires simultaneously addressing both allocation-level and phase-level imbalance.
- Open Access
- 16 July 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 264
Determining lower and upper bounds for active power calculated from synchronized measurements in system integrity protection applications
- 16 July 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 264
Open AccessDetermining lower and upper bounds for active power calculated from synchronized measurements in system integrity protection applications
- Open Access
- 19 April 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 232
Novel IEC 61850-based off-site engineering and validation methodology for protection, automation, and control systems
- 19 April 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 232
Open AccessNovel IEC 61850-based off-site engineering and validation methodology for protection, automation, and control systems
- Open Access
Performance Analysis of Overcurrent Protection under Corrupted Sampled Value Frames: A Hardware-in-the-Loop Approach
The IEC 61850 standard aims at digitization substations and provides interoperability between various Intelligent Electronic Device vendors. The digitization process is accompanied by several challenges related to data transmission on the ethernet network and the protection behavior under these conditions. Among the challenges, we can mention packet loss, delay, and duplicate frame, which occurs when the merging units (publisher) transmit the sampled values and, for some reason, these packets do not reach the subscriber or are duplicated. Nowadays, most Intelligent Electronic Device manufacturers block the protection function when some sampled value packets are corrupted. The effects of blocking protection when packet loss occurs under normal operating conditions do not cause significant problems. However, when a fault occurs, the corrupted packets can cause a delay in fault clearance, causing even more damage to the grid. The purpose of this article is to present the effects of corrupted sampled values on the performance of overcurrent protection. All the evaluations were performed in real time using the hardware-in-loop simulation approach with a commercial Intelligent Electronic Device. The OP5700 hardware platform from OPAL-RT, with the library “IEC 61850 Data Integrity Manipulation”, was used. The results show that corrupted sampled value frames affect the functioning of the protections.
Open AccessPerformance Analysis of Overcurrent Protection under Corrupted Sampled Value Frames: A Hardware-in-the-Loop Approach
The IEC 61850 standard aims at digitization substations and provides interoperability between various Intelligent Electronic Device vendors. The digitization process is accompanied by several challenges related to data transmission on the ethernet network and the protection behavior under these conditions. Among the challenges, we can mention packet loss, delay, and duplicate frame, which occurs when the merging units (publisher) transmit the sampled values and, for some reason, these packets do not reach the subscriber or are duplicated. Nowadays, most Intelligent Electronic Device manufacturers block the protection function when some sampled value packets are corrupted. The effects of blocking protection when packet loss occurs under normal operating conditions do not cause significant problems. However, when a fault occurs, the corrupted packets can cause a delay in fault clearance, causing even more damage to the grid. The purpose of this article is to present the effects of corrupted sampled values on the performance of overcurrent protection. All the evaluations were performed in real time using the hardware-in-loop simulation approach with a commercial Intelligent Electronic Device. The OP5700 hardware platform from OPAL-RT, with the library “IEC 61850 Data Integrity Manipulation”, was used. The results show that corrupted sampled value frames affect the functioning of the protections.
- 1 January 2016
- Published by Elsevier in Electric Power Systems Research
- Vol. 130, 148-155
An ANN based forecast for IED network management using the IEC61850 standard
- 1 January 2016
- Published by Elsevier in Electric Power Systems Research
- Vol. 130, 148-155
An ANN based forecast for IED network management using the IEC61850 standard