Performance Analysis of Overcurrent Protection under Corrupted Sampled Value Frames: A Hardware-in-the-Loop Approach
Open Access
Abstract
The IEC 61850 standard aims at digitization substations and provides interoperability between various Intelligent Electronic Device vendors. The digitization process is accompanied by several challenges related to data transmission on the ethernet network and the protection behavior under these conditions. Among the challenges, we can mention packet loss, delay, and duplicate frame, which occurs when the merging units (publisher) transmit the sampled values and, for some reason, these packets do not reach the subscriber or are duplicated. Nowadays, most Intelligent Electronic Device manufacturers block the protection function when some sampled value packets are corrupted. The effects of blocking protection when packet loss occurs under normal operating conditions do not cause significant problems. However, when a fault occurs, the corrupted packets can cause a delay in fault clearance, causing even more damage to the grid. The purpose of this article is to present the effects of corrupted sampled values on the performance of overcurrent protection. All the evaluations were performed in real time using the hardware-in-loop simulation approach with a commercial Intelligent Electronic Device. The OP5700 hardware platform from OPAL-RT, with the library “IEC 61850 Data Integrity Manipulation”, was used. The results show that corrupted sampled value frames affect the functioning of the protections.Keywords
Funding Information
- CPFL Energia (001)
This publication has 17 references indexed in Scilit:
- Controller Hardware-in-the-Loop Testing of an IEC 61850 GOOSE Based Control for Seamless Transition of a Microgrid Between Island and Grid-Connected ModesIEEE Transactions on Industry Applications, 2020
- Review of Modern Methods for Busbar Protection Implementation2020
- IEC 61850-Based Centralized Busbar Differential Protection with Data Desynchronization CompensationEnergies, 2020
- Online false data detection and lost packet forecasting system using time series neural networks for IEC 61850 sampled measured values2017
- Interpreting and implementing IEC 61850-90-5 Routed-Sampled Value and Routed-GOOSE protocols for IEEE C37.118.2 compliant wide-area synchrophasor data transferElectric Power Systems Research, 2017
- Investigating cyber-physical attacks against IEC 61850 photovoltaic inverter installations2015
- Real-time co-simulation platform using OPAL-RT and OPNET for analyzing smart grid performance2015
- The Impact of IEC 61850 on Transmission and Distribution Substations Busbar Protection2014
- Impact of IEC 61850-9-2 Standard-Based Process Bus on the Operating Performance of Protection IEDS: Comparative StudyIFAC Proceedings Volumes, 2014
- Laboratory Investigation of IEC 61850-9-2-Based Busbar and Distance Relaying With Corrective Measure for Sampled Value Loss/DelayIEEE Transactions on Power Delivery, 2011