S. Takami
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
S. Takami has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- A. Forgeas
ITER Organization, Route de Vinon sur Verdon, 13115 St Paul lez Durance, France
2 shared publications - R. Maekawa
ITER Organization, Route de Vinon sur Verdon, 13115 St Paul lez Durance, France
2 shared publications - Akifumi Iwamoto
National Institute for Fusion Science, Toki, Gifu, Japan
1 shared publication B. Rousset
CEA-Grenoble, Grenoble Cedex 9, France
1 shared publicationC. Hoa
CEA-Grenoble, Grenoble Cedex 9, France
1 shared publication- H.-S. Chang
ITER Organization, St. Paul Lez durance Cedex, France
1 shared publication
Latest Publications
- 1 December 2016
- Published by Elsevier in Cryogenics
- Vol. 80, 284-293
Process control strategy for ITER central solenoid operation
- 1 December 2016
- Published by Elsevier in Cryogenics
- Vol. 80, 284-293
Process control strategy for ITER central solenoid operation
- 5 March 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 22 (3) , 4704004
Dynamic Simulation of Sub-Scale ITER CS/STR Cooling Loop
The dynamic simulation of a sub-scale ITER Central Solenoid (CS)/STRucture (STR) cooling loop has been performed to investigate the cryogenic control strategies against pulsating heat loads. HELIOS facility has been modified for this particular study, which consists of a Liquid Helium (LHe) reservoir with two immersed heat exchangers, a circulation pump and an approximately 130 m long piping with three evenly distributed heated sections. The setup provides the equivalent thermo-hydraulic configuration of the ITER CS/STR, cooled by the forced-flow Supercritical Helium (SHe). The dynamic simulator, C-PREST, has been utilized to model the HELIOS test loop and to compare the results with the experimental data sets. This paper presents the dynamic simulation results and discusses the control strategy to minimize the cooling power requirements, to have high reliability.
- 5 March 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 22 (3) , 4704004
Dynamic Simulation of Sub-Scale ITER CS/STR Cooling Loop
The dynamic simulation of a sub-scale ITER Central Solenoid (CS)/STRucture (STR) cooling loop has been performed to investigate the cryogenic control strategies against pulsating heat loads. HELIOS facility has been modified for this particular study, which consists of a Liquid Helium (LHe) reservoir with two immersed heat exchangers, a circulation pump and an approximately 130 m long piping with three evenly distributed heated sections. The setup provides the equivalent thermo-hydraulic configuration of the ITER CS/STR, cooled by the forced-flow Supercritical Helium (SHe). The dynamic simulator, C-PREST, has been utilized to model the HELIOS test loop and to compare the results with the experimental data sets. This paper presents the dynamic simulation results and discusses the control strategy to minimize the cooling power requirements, to have high reliability.