Dynamic Simulation of Sub-Scale ITER CS/STR Cooling Loop
- 5 March 2012
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 22 (3) , 4704004
Abstract
The dynamic simulation of a sub-scale ITER Central Solenoid (CS)/STRucture (STR) cooling loop has been performed to investigate the cryogenic control strategies against pulsating heat loads. HELIOS facility has been modified for this particular study, which consists of a Liquid Helium (LHe) reservoir with two immersed heat exchangers, a circulation pump and an approximately 130 m long piping with three evenly distributed heated sections. The setup provides the equivalent thermo-hydraulic configuration of the ITER CS/STR, cooled by the forced-flow Supercritical Helium (SHe). The dynamic simulator, C-PREST, has been utilized to model the HELIOS test loop and to compare the results with the experimental data sets. This paper presents the dynamic simulation results and discusses the control strategy to minimize the cooling power requirements, to have high reliability.Keywords
This publication has 4 references indexed in Scilit:
- ITER cryogenic system validation tests at helios test facilityAIP Conference Proceedings, 2012
- CHALLENGES FOR CRYOGENICS AT ITERAIP Conference Proceedings, 2010
- Scale‐Up in Chemical Engineering2002
- Design of the ITER–FEAT cryoplant to achieve stable operation over a wide range of experimental parameters and operation scenariosFusion Engineering and Design, 2001