Kerry D. Solomon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kerry D. Solomon has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Richard Potvin
Science in Vision
7 shared publications Helga P Sandoval
Carolina Eyecare Physicians, LLC, Mt. Pleasant, SC, USA
4 shared publicationsHelga P. Sandoval
Carolina Eyecare Physicians, LLC, Mt. Pleasant, South Carolina, USA
3 shared publications- Eric Donnenfeld
Ophthalmic Consultants of Long Island, Garden City, NY, USA
2 shared publications Bonnie An Henderson
Ophthalmic Consultants of Boston, Boston, MA, USA
1 shared publicationChad Serels
From the Carolina Eyecare Physicians, LLC, Mt. Pleasant, South Carolina (Sandoval, Serels, Solomon); Science in Vision, Akron, New York (Potvin). C. Serels is now at UH Regional Hospitals, Richmond Heights, Ohio
1 shared publication
Latest Publications
- 2 November 2020
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 47 (4) , 465-470
Cataract surgery after myopic laser in situ keratomileusis: objective analysis to determine best formula and keratometry to use
Purpose: To objectively determine which formula/keratometry combination was best for calculating intraocular lens (IOL) sphere power in eyes with a history of myopic laser in situ keratomileusis (LASIK). Setting: One practice in the United States. Design: Retrospective, unmasked, nonrandomized chart review. Methods: Consecutive patients undergoing cataract surgery after previous myopic LASIK were included. Eyes had to have a postoperative refraction at least 3 weeks postoperatively. IOL power was calculated with the ASCRS online postrefractive IOL calculator using anterior keratometry and recalculated using total corneal power (TK). The accuracy of treatment was calculated and compared between different formulas and keratometry methods including intraoperative aberrometry (IA). Results: Data from 101 eyes, 44 of which had TK available, were analyzed. Using TK, the Wang-Koch-Maloney formula had the highest percentages of eyes with expected spherical equivalent refractive errors within 0.50 diopter (D) and 1.00 D of plano (57% and 87%, respectively). With anterior keratometry, the Barrett True-K formula had the highest percentages (64% and 92%, respectively) but was not significantly better than the Wang-Koch-Maloney formula, with expected errors within ±0.50 and ±1.00 D (P > .2, McNemar test). Expected sphere results based on IA were not significantly different than for Barrett True-K within ±0.50 D or within ±1.00 D (P > .2, McNemar test). Conclusions: Using TK in existing post-LASIK formulas did not seem beneficial. The formulas might have to be optimized for use with TK. The best expected results were obtained with the Barrett True-K and Haigis-L formulas using anterior keratometry. IA did not seem to materially improve results.
- 2 November 2020
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 47 (4) , 465-470
Cataract surgery after myopic laser in situ keratomileusis: objective analysis to determine best formula and keratometry to use
Purpose: To objectively determine which formula/keratometry combination was best for calculating intraocular lens (IOL) sphere power in eyes with a history of myopic laser in situ keratomileusis (LASIK). Setting: One practice in the United States. Design: Retrospective, unmasked, nonrandomized chart review. Methods: Consecutive patients undergoing cataract surgery after previous myopic LASIK were included. Eyes had to have a postoperative refraction at least 3 weeks postoperatively. IOL power was calculated with the ASCRS online postrefractive IOL calculator using anterior keratometry and recalculated using total corneal power (TK). The accuracy of treatment was calculated and compared between different formulas and keratometry methods including intraoperative aberrometry (IA). Results: Data from 101 eyes, 44 of which had TK available, were analyzed. Using TK, the Wang-Koch-Maloney formula had the highest percentages of eyes with expected spherical equivalent refractive errors within 0.50 diopter (D) and 1.00 D of plano (57% and 87%, respectively). With anterior keratometry, the Barrett True-K formula had the highest percentages (64% and 92%, respectively) but was not significantly better than the Wang-Koch-Maloney formula, with expected errors within ±0.50 and ±1.00 D (P > .2, McNemar test). Expected sphere results based on IA were not significantly different than for Barrett True-K within ±0.50 D or within ±1.00 D (P > .2, McNemar test). Conclusions: Using TK in existing post-LASIK formulas did not seem beneficial. The formulas might have to be optimized for use with TK. The best expected results were obtained with the Barrett True-K and Haigis-L formulas using anterior keratometry. IA did not seem to materially improve results.
- Open Access
- 1 September 2020
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 14, 2667-2677
Visual Acuity, Defocus Curve, Reading Speed and Patient Satisfaction with a Combined Extended Depth of Focus Intraocular Lens and Multifocal Intraocular Lens Modality
Purpose: To evaluate the vision, defocus curve, reading speed and patient satisfaction after implantation of an extended depth of focus (EDOF) IOL in one eye and a diffractive multifocal in the fellow eye. Setting: One clinical practice in the USA. Design: Prospective unmasked non-randomized clinical trial. Methods: Subjects presenting for routine cataract surgery interested in reducing their dependence on spectacles were enrolled. Study endpoints included uncorrected and distance-corrected binocular distance (4 m), intermediate (66 cm) and near (40 cm) visual acuity at 3 months. Additional endpoints included the residual refraction, spectacle independence, overall satisfaction with vision, visual symptoms, reading speed and defocus curve. Results: With a best distance correction, 77% (30/39) of subjects had 20/25 or better VA at distance, intermediate and near and nearly all subjects had 20/32 or better VA at all three distances. Defocus curve results showed mean continuous vision of 20/25 or better from plano to − 2.50 D. Nearly 80% (31/39) of subjects had 20/25 visual acuity from 0.00 D to − 2.50 D. The critical print size was between 0.3 and 0.4 logMAR (20/40 to 20/50 Snellen Equivalent). Spectacle independence was 100% at distance, 95% at intermediate and approximately 70% at near. The percentage of subjects who were “not at all” or “slightly” bothered by visual disturbances ranged from 64% (16/25) for Halos to 88% (22/25) for Starbursts. Conclusions: EDOF/bifocal IOL blended implantation results in at least 20/25 mean visual acuity from distance to near with good spectacle independence and low reports of severe visual disturbances.
- 1 September 2020
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 14, 2667-2677
Open AccessVisual Acuity, Defocus Curve, Reading Speed and Patient Satisfaction with a Combined Extended Depth of Focus Intraocular Lens and Multifocal Intraocular Lens Modality
Purpose: To evaluate the vision, defocus curve, reading speed and patient satisfaction after implantation of an extended depth of focus (EDOF) IOL in one eye and a diffractive multifocal in the fellow eye. Setting: One clinical practice in the USA. Design: Prospective unmasked non-randomized clinical trial. Methods: Subjects presenting for routine cataract surgery interested in reducing their dependence on spectacles were enrolled. Study endpoints included uncorrected and distance-corrected binocular distance (4 m), intermediate (66 cm) and near (40 cm) visual acuity at 3 months. Additional endpoints included the residual refraction, spectacle independence, overall satisfaction with vision, visual symptoms, reading speed and defocus curve. Results: With a best distance correction, 77% (30/39) of subjects had 20/25 or better VA at distance, intermediate and near and nearly all subjects had 20/32 or better VA at all three distances. Defocus curve results showed mean continuous vision of 20/25 or better from plano to − 2.50 D. Nearly 80% (31/39) of subjects had 20/25 visual acuity from 0.00 D to − 2.50 D. The critical print size was between 0.3 and 0.4 logMAR (20/40 to 20/50 Snellen Equivalent). Spectacle independence was 100% at distance, 95% at intermediate and approximately 70% at near. The percentage of subjects who were “not at all” or “slightly” bothered by visual disturbances ranged from 64% (16/25) for Halos to 88% (22/25) for Starbursts. Conclusions: EDOF/bifocal IOL blended implantation results in at least 20/25 mean visual acuity from distance to near with good spectacle independence and low reports of severe visual disturbances.
- Open Access
- 1 August 2020
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 14, 2405-2410
Evaluating Rotational Stability of an Extended Depth of Focus Toric Intraocular Lens Using a Slit Lamp and Image-Based Analysis
Purpose: To evaluate the rotational stability of a toric extended depth of focus (EDOF) intraocular lens (IOL), using either slit lamp evaluation or image-processing software. Setting: Three clinical practices in the USA. Design: Prospective unmasked randomized clinical trial. Methods: Subjects presenting for routine cataract surgery that were interested in improved near vision received toric EDOF lenses (TECNIS Symfony® Toric) in both eyes. The measures of interest in the current analysis were the change in orientation of the IOL between 1 day, 1 month and 3 months postoperative. Orientation was measured at the microscope on the day of surgery, and with the slit lamp at all other visits. Day 1, 1-month and 3-month images of the lens orientation were captured with a slit lamp camera. Differences in orientation were recorded and analyzed. Results: A total of 150 eyes had IOL orientation data available. Image analysis showed mean absolute lens orientation changes from 1 day to 1 month and 3 months of less than 2 degrees. The percentage of lenses exhibiting rotation of ≤ 5 degrees between any measured time points was 97% or higher. Results were similar, but significantly more variable, when IOL orientation was measured at the slit lamp. Conclusion: The toric EDOF lens evaluated here demonstrated rotational stability that exceeded the prior ANSI standard. The best method to determine IOL orientation changes was through image analysis.
- 1 August 2020
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 14, 2405-2410
Open AccessEvaluating Rotational Stability of an Extended Depth of Focus Toric Intraocular Lens Using a Slit Lamp and Image-Based Analysis
Purpose: To evaluate the rotational stability of a toric extended depth of focus (EDOF) intraocular lens (IOL), using either slit lamp evaluation or image-processing software. Setting: Three clinical practices in the USA. Design: Prospective unmasked randomized clinical trial. Methods: Subjects presenting for routine cataract surgery that were interested in improved near vision received toric EDOF lenses (TECNIS Symfony® Toric) in both eyes. The measures of interest in the current analysis were the change in orientation of the IOL between 1 day, 1 month and 3 months postoperative. Orientation was measured at the microscope on the day of surgery, and with the slit lamp at all other visits. Day 1, 1-month and 3-month images of the lens orientation were captured with a slit lamp camera. Differences in orientation were recorded and analyzed. Results: A total of 150 eyes had IOL orientation data available. Image analysis showed mean absolute lens orientation changes from 1 day to 1 month and 3 months of less than 2 degrees. The percentage of lenses exhibiting rotation of ≤ 5 degrees between any measured time points was 97% or higher. Results were similar, but significantly more variable, when IOL orientation was measured at the slit lamp. Conclusion: The toric EDOF lens evaluated here demonstrated rotational stability that exceeded the prior ANSI standard. The best method to determine IOL orientation changes was through image analysis.
- Open Access
- 1 July 2020
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 14, 1959-1965
Comparing Combination Drop Therapy to a Standard Drop Regimen After Routine Cataract Surgery
Purpose: To evaluate the efficacy of a combined steroid/antibiotic/non-steroidal anti-inflammatory drop relative to a regimen of multiple drops after cataract surgery. Setting: Single clinical practice in the USA. Design: Prospective randomized contralateral eye study. Methods: Subjects presenting for bilateral cataract surgery were enrolled with contralateral eyes randomly assigned to one of the two groups. Test eyes received a combination therapy (prednisolone acetate 1%, gatifloxacin 0.5%, and bromfenac sodium 0.075%) while control eyes received the same medications in separate drops (bromfenac sodium was 0.07%). Subjects were examined 1, 15 and 30 days after surgery. Visual acuities were measured, along with the refraction, intraocular pressure, patient pain and satisfaction, macular thickness and corneal pachymetry. The primary measure of interest was the change in macular thickness from baseline to the 15- and 30-day visits. The frequency and severity of reported ocular adverse events were tabulated for each group and compared. Results: Thirty-three subjects completed the study. Changes in central macular thickness were similar between groups, with only one control eye exhibiting significant macular edema. No differences in visual acuity, corneal edema, cells or flare were observed between groups. There were eight mild adverse events reported for all eyes of all subjects; the difference in the number of eyes experiencing adverse events was not statistically significantly different between groups (p ≥ 0.05 for all comparisons). While subjective symptoms were similar, all subjects indicated that they preferred the combination drop. Conclusion: A combination drop showed similar efficacy to multiple drops and was overwhelmingly preferred by subjects.
- 1 July 2020
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 14, 1959-1965
Open AccessComparing Combination Drop Therapy to a Standard Drop Regimen After Routine Cataract Surgery
Purpose: To evaluate the efficacy of a combined steroid/antibiotic/non-steroidal anti-inflammatory drop relative to a regimen of multiple drops after cataract surgery. Setting: Single clinical practice in the USA. Design: Prospective randomized contralateral eye study. Methods: Subjects presenting for bilateral cataract surgery were enrolled with contralateral eyes randomly assigned to one of the two groups. Test eyes received a combination therapy (prednisolone acetate 1%, gatifloxacin 0.5%, and bromfenac sodium 0.075%) while control eyes received the same medications in separate drops (bromfenac sodium was 0.07%). Subjects were examined 1, 15 and 30 days after surgery. Visual acuities were measured, along with the refraction, intraocular pressure, patient pain and satisfaction, macular thickness and corneal pachymetry. The primary measure of interest was the change in macular thickness from baseline to the 15- and 30-day visits. The frequency and severity of reported ocular adverse events were tabulated for each group and compared. Results: Thirty-three subjects completed the study. Changes in central macular thickness were similar between groups, with only one control eye exhibiting significant macular edema. No differences in visual acuity, corneal edema, cells or flare were observed between groups. There were eight mild adverse events reported for all eyes of all subjects; the difference in the number of eyes experiencing adverse events was not statistically significantly different between groups (p ≥ 0.05 for all comparisons). While subjective symptoms were similar, all subjects indicated that they preferred the combination drop. Conclusion: A combination drop showed similar efficacy to multiple drops and was overwhelmingly preferred by subjects.
- Open Access
- 1 June 2020
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 14, 1791-1798
Defocus Curve and Patient Satisfaction with a New Extended Depth of Focus Toric Intraocular Lens Targeted for Binocular Emmetropia or Slight Myopia in the Non-Dominant Eye
Purpose: To evaluate the defocus curve and patient satisfaction after implantation of an extended depth of focus (EDOF) toric IOL when both eyes were targeted for emmetropia and when the non-dominant eye was targeted for mini monovision (− 0.50D). Methods: A prospective unmasked randomized clinical trial in three clinical practices in the USA. Subjects presenting for routine cataract surgery were assigned to one of two groups, both receiving bilateral toric EDOF lenses. One group had the non-dominant eye targeted for slight myopia (− 0.50D). Measures of interest were the postoperative defocus curve and reported patient satisfaction and visual disturbances. Results: Questionnaire and defocus curve data were available from 37 subjects in the Emmetropia group, while the mini monovision group included questionnaire data from 39 subjects and valid defocus curve data from 14 subjects. Mini monovision subjects had significantly better VA (a half line to a line better, p < 0.05), from a defocus of − 1.50 D to − 3.00 D. Reported spectacle wear and satisfaction were not significantly different between groups at any distance, but more patients in the mini monovision group reported the ability to function comfortably without glasses at near and overall (near p = 0.02, overall p < 0.01). Halos and starbursts were the two phenomena reported most often for both groups, with reported starbursts slightly more common in the mini monovision group. Conclusions: A slightly myopic correction in the non-dominant eye improved binocular near vision by 0.5 to 1.0 lines based on defocus curve data. Patients reported better functional vision, but with a slight increase in reported starbursts in the mini monovision group.
- 1 June 2020
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 14, 1791-1798
Open AccessDefocus Curve and Patient Satisfaction with a New Extended Depth of Focus Toric Intraocular Lens Targeted for Binocular Emmetropia or Slight Myopia in the Non-Dominant Eye
Purpose: To evaluate the defocus curve and patient satisfaction after implantation of an extended depth of focus (EDOF) toric IOL when both eyes were targeted for emmetropia and when the non-dominant eye was targeted for mini monovision (− 0.50D). Methods: A prospective unmasked randomized clinical trial in three clinical practices in the USA. Subjects presenting for routine cataract surgery were assigned to one of two groups, both receiving bilateral toric EDOF lenses. One group had the non-dominant eye targeted for slight myopia (− 0.50D). Measures of interest were the postoperative defocus curve and reported patient satisfaction and visual disturbances. Results: Questionnaire and defocus curve data were available from 37 subjects in the Emmetropia group, while the mini monovision group included questionnaire data from 39 subjects and valid defocus curve data from 14 subjects. Mini monovision subjects had significantly better VA (a half line to a line better, p < 0.05), from a defocus of − 1.50 D to − 3.00 D. Reported spectacle wear and satisfaction were not significantly different between groups at any distance, but more patients in the mini monovision group reported the ability to function comfortably without glasses at near and overall (near p = 0.02, overall p < 0.01). Halos and starbursts were the two phenomena reported most often for both groups, with reported starbursts slightly more common in the mini monovision group. Conclusions: A slightly myopic correction in the non-dominant eye improved binocular near vision by 0.5 to 1.0 lines based on defocus curve data. Patients reported better functional vision, but with a slight increase in reported starbursts in the mini monovision group.
- 1 October 2019
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 45 (10) , 1430-1435
Evaluating the relative value of intraoperative aberrometry versus current formulas for toric IOL sphere, cylinder, and orientation planning
To retrospectively review toric intraocular lens (IOL) outcomes and compare actual results to those expected from preoperative calculations and intraoperative aberrometry (IA) in normal eyes. Carolina Eyecare Physicians, Mt. Pleasant, South Carolina, USA. Retrospective data review of earlier clinical trial data. Toric IOL planning data and results were obtained from two previous clinical studies of normal eyes receiving toric IOL implants. Back-calculation techniques were used to estimate expected residual refractive sphere and cylinder for preoperative and IA calculations. Toric IOL planning data and clinical outcomes for 132 eyes receiving two different toric IOLs were analyzed. The mean spherical equivalent refractions expected with preoperative planning and IA were not statistically significantly different (P = .44), but a higher percentage of eyes within ±0.50 D of the intended spherical refraction was expected with preoperative calculations (P = .05). The mean expected residual refractive astigmatism based on preoperative calculations was significantly lower than for IA (P < .001), with more eyes expected to have 0.50 D or less of residual refractive astigmatism. The use of current-generation formulas for sphere power and toric IOL planning in normal eyes seems sufficient to produce clinical outcomes with toric IOLs that are as good or better than those achieved using IA.
- 1 October 2019
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 45 (10) , 1430-1435
Evaluating the relative value of intraoperative aberrometry versus current formulas for toric IOL sphere, cylinder, and orientation planning
To retrospectively review toric intraocular lens (IOL) outcomes and compare actual results to those expected from preoperative calculations and intraoperative aberrometry (IA) in normal eyes. Carolina Eyecare Physicians, Mt. Pleasant, South Carolina, USA. Retrospective data review of earlier clinical trial data. Toric IOL planning data and results were obtained from two previous clinical studies of normal eyes receiving toric IOL implants. Back-calculation techniques were used to estimate expected residual refractive sphere and cylinder for preoperative and IA calculations. Toric IOL planning data and clinical outcomes for 132 eyes receiving two different toric IOLs were analyzed. The mean spherical equivalent refractions expected with preoperative planning and IA were not statistically significantly different (P = .44), but a higher percentage of eyes within ±0.50 D of the intended spherical refraction was expected with preoperative calculations (P = .05). The mean expected residual refractive astigmatism based on preoperative calculations was significantly lower than for IA (P < .001), with more eyes expected to have 0.50 D or less of residual refractive astigmatism. The use of current-generation formulas for sphere power and toric IOL planning in normal eyes seems sufficient to produce clinical outcomes with toric IOLs that are as good or better than those achieved using IA.
- 1 May 2019
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 45 (5) , 569-575
Correcting astigmatism at the time of cataract surgery: Toric IOLs and corneal relaxing incisions planned with an image-guidance system and intraoperative aberrometer versus manual planning and surgery
To compare the outcomes of the combination of an image-guided system and intraoperative aberrometer with the surgeon's standard of care in correcting astigmatism using toric intraocular lenses (IOLs) or corneal incisions. Single site in United States. Prospective case series. Contralateral eyes of patients having uncomplicated bilateral cataract surgery and astigmatism correction were randomly assigned to Group A or Group B. Group A received the surgeon's preferred standard of care. Group B had preoperative planning using an image-guidance system (VERION), intraoperative aberrometry (ORA System with VerifEye+), and femtosecond laser-assisted cataract surgery. The primary endpoint was the residual refractive astigmatism at 3 months. Thirty-eight eyes were treated with toric IOLs and 40 eyes with corneal astigmatic incisions. On average, toric IOLs resulted in almost 0.25 diopter (D) less cylinder than corneal astigmatic incisions (P < .01), with no difference between groups (P = .41). There was no statistically significant difference in the mean spherical equivalent refraction by group (P = .51). At 3 months, the IOL in 4 eyes (11%) (2 in Group A and Group B each) was more than 10 degrees of absolute orientation from the intended orientation. The mean keratometry was 0.16 D higher with the image-guided system compared with optical biometry (Lenstar). The vector difference between the 2 measurements was 0.5 D or lower in all eyes. The combined use of an image-guided system and intraoperative aberrometer did not significantly improve outcomes compared with the surgeon's standard of care. Based on keratometry, there was good agreement in corneal astigmatism measurements between the image-guided system and the optical biometer.
- 1 May 2019
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 45 (5) , 569-575
Correcting astigmatism at the time of cataract surgery: Toric IOLs and corneal relaxing incisions planned with an image-guidance system and intraoperative aberrometer versus manual planning and surgery
To compare the outcomes of the combination of an image-guided system and intraoperative aberrometer with the surgeon's standard of care in correcting astigmatism using toric intraocular lenses (IOLs) or corneal incisions. Single site in United States. Prospective case series. Contralateral eyes of patients having uncomplicated bilateral cataract surgery and astigmatism correction were randomly assigned to Group A or Group B. Group A received the surgeon's preferred standard of care. Group B had preoperative planning using an image-guidance system (VERION), intraoperative aberrometry (ORA System with VerifEye+), and femtosecond laser-assisted cataract surgery. The primary endpoint was the residual refractive astigmatism at 3 months. Thirty-eight eyes were treated with toric IOLs and 40 eyes with corneal astigmatic incisions. On average, toric IOLs resulted in almost 0.25 diopter (D) less cylinder than corneal astigmatic incisions (P < .01), with no difference between groups (P = .41). There was no statistically significant difference in the mean spherical equivalent refraction by group (P = .51). At 3 months, the IOL in 4 eyes (11%) (2 in Group A and Group B each) was more than 10 degrees of absolute orientation from the intended orientation. The mean keratometry was 0.16 D higher with the image-guided system compared with optical biometry (Lenstar). The vector difference between the 2 measurements was 0.5 D or lower in all eyes. The combined use of an image-guided system and intraoperative aberrometer did not significantly improve outcomes compared with the surgeon's standard of care. Based on keratometry, there was good agreement in corneal astigmatism measurements between the image-guided system and the optical biometer.
- 1 August 2016
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 42 (8) , 1224-1234
Modern laser in situ keratomileusis outcomes
Laser in situ keratomileusis (LASIK) articles published between 2008 and 2015 that contain clinical outcomes data were reviewed and graded for quality, impression, and potential bias. All 97 relevant articles (representing 67 893 eyes) provided a positive or neutral impression of LASIK. Industry bias was not evident. The aggregate loss of 2 or more lines of corrected distance visual acuity was 0.61% (359/58 653). The overall percentage of eyes with uncorrected distance visual acuity better than 20/40 was 99.5% (59 503/59 825). The spherical equivalent refraction was within ±1.0 diopter (D) of the target refraction in 98.6% (59 476/60 329) of eyes, with 90.9% (59 954/65 974) within ±0.5 D. In studies reporting patient satisfaction, 1.2% (129/9726) of patients were dissatisfied with LASIK. Aggregate outcomes appear better than those reported in summaries of the safety and effectiveness of earlier laser refractive surgery systems approved by the U.S. Food and Drug Administration. Modern results support the safety, efficacy, and patient satisfaction of the procedure. Proprietary or commercial disclosures are listed after the references.
- 1 August 2016
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 42 (8) , 1224-1234
Modern laser in situ keratomileusis outcomes
Laser in situ keratomileusis (LASIK) articles published between 2008 and 2015 that contain clinical outcomes data were reviewed and graded for quality, impression, and potential bias. All 97 relevant articles (representing 67 893 eyes) provided a positive or neutral impression of LASIK. Industry bias was not evident. The aggregate loss of 2 or more lines of corrected distance visual acuity was 0.61% (359/58 653). The overall percentage of eyes with uncorrected distance visual acuity better than 20/40 was 99.5% (59 503/59 825). The spherical equivalent refraction was within ±1.0 diopter (D) of the target refraction in 98.6% (59 476/60 329) of eyes, with 90.9% (59 954/65 974) within ±0.5 D. In studies reporting patient satisfaction, 1.2% (129/9726) of patients were dissatisfied with LASIK. Aggregate outcomes appear better than those reported in summaries of the safety and effectiveness of earlier laser refractive surgery systems approved by the U.S. Food and Drug Administration. Modern results support the safety, efficacy, and patient satisfaction of the procedure. Proprietary or commercial disclosures are listed after the references.
- 1 April 2016
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 42 (4) , 542-549
Clinical study using a new phacoemulsification system with surgical intraocular pressure control
To compare cumulative dissipated energy (CDE), aspiration fluid used, and aspiration time during phacoemulsification cataract extraction using 2 surgical configurations. Two clinical sites in the United States and 1 in Spain. Prospective randomized clinical case series. For each patient, the first eye having surgery was randomized to the active-fluidics configuration (Centurion Vision System with Active Fluidics, 0.9 mm 45-degree Intrepid Balanced tip, and 0.9 mm Intrepid Ultra infusion sleeve) or the gravity-fluidics configuration (Infiniti Vision System with gravity fluidics, 0.9 mm 45-degree Mini-Flared Kelman tip, and 0.9 mm Ultra infusion sleeve). Second-eye surgery was completed within 14 days after first-eye surgery using the alternate configuration. The CDE, aspiration fluid used, and aspiration time were compared between configurations, and adverse events were summarized. Patient demographics and cataract characteristics were similar between configurations (100 per group). The CDE was significantly lower with the active-fluidics configuration than with the gravity-fluidics configuration (mean ± standard error, 4.32 ± 0.28 percent-seconds) (P < .001). The active-fluidics configuration used significantly less aspiration fluid than the gravity-fluidics configuration (mean 46.56 ± 1.39 mL versus 52.68 ± 1.40 mL) (P < .001) and required significantly shorter aspiration time (mean 151.9 ± 4.1 seconds versus 167.6 ± 4.1 seconds) (P < .001). No serious ocular adverse events related to the study devices or device deficiencies were observed. Significantly less CDE, aspiration fluid used, and aspiration time were observed with the active-fluidics configuration than with the gravity-fluidics configuration, showing improved surgical efficiency. Drs. Solomon and Cionni are consultants to Alcon Research, Ltd., and received compensation for conduct of the study. Dr. Lorente received compensation for clinical work in the study. Mr. Fanney is an employee of Alcon Research, Ltd.
- 1 April 2016
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 42 (4) , 542-549
Clinical study using a new phacoemulsification system with surgical intraocular pressure control
To compare cumulative dissipated energy (CDE), aspiration fluid used, and aspiration time during phacoemulsification cataract extraction using 2 surgical configurations. Two clinical sites in the United States and 1 in Spain. Prospective randomized clinical case series. For each patient, the first eye having surgery was randomized to the active-fluidics configuration (Centurion Vision System with Active Fluidics, 0.9 mm 45-degree Intrepid Balanced tip, and 0.9 mm Intrepid Ultra infusion sleeve) or the gravity-fluidics configuration (Infiniti Vision System with gravity fluidics, 0.9 mm 45-degree Mini-Flared Kelman tip, and 0.9 mm Ultra infusion sleeve). Second-eye surgery was completed within 14 days after first-eye surgery using the alternate configuration. The CDE, aspiration fluid used, and aspiration time were compared between configurations, and adverse events were summarized. Patient demographics and cataract characteristics were similar between configurations (100 per group). The CDE was significantly lower with the active-fluidics configuration than with the gravity-fluidics configuration (mean ± standard error, 4.32 ± 0.28 percent-seconds) (P < .001). The active-fluidics configuration used significantly less aspiration fluid than the gravity-fluidics configuration (mean 46.56 ± 1.39 mL versus 52.68 ± 1.40 mL) (P < .001) and required significantly shorter aspiration time (mean 151.9 ± 4.1 seconds versus 167.6 ± 4.1 seconds) (P < .001). No serious ocular adverse events related to the study devices or device deficiencies were observed. Significantly less CDE, aspiration fluid used, and aspiration time were observed with the active-fluidics configuration than with the gravity-fluidics configuration, showing improved surgical efficiency. Drs. Solomon and Cionni are consultants to Alcon Research, Ltd., and received compensation for conduct of the study. Dr. Lorente received compensation for clinical work in the study. Mr. Fanney is an employee of Alcon Research, Ltd.
- Open Access
- 1 August 2014
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. 8, 1595-602
A survey of potential and previous cataract-surgery patients: what the ophthalmologist should know
A survey of potential and previous cataract-surgery patients: what the ophthalmologist should know Bonnie An Henderson,1 Kerry Solomon,2 Samuel Masket,3 Richard Potvin,4 Edward J Holland,5 Robert Cionni,6 Helga Sandoval2 1Ophthalmic Consultants of Boston, Boston, MA, 2Carolina Eyecare Research Institute, Carolina Eyecare Physicians, Mount Pleasant, SC, 3Advanced Vision Care, Los Angeles, CA, 4Science in Vision, Akron, NY, 5Cincinnati Eye Institute, Cincinnati, OH, 6Eye Institute of Utah, Salt Lake City, UT, USA Objective: This study utilized a phone survey to characterize patient perceptions of cataract surgery and the manner in which the ophthalmologist contributes to the patient’s understanding in electing cataract surgery.Patients and methods: Calls were made from a randomized membership list of the American Association of Retired Persons until 1,000 respondents 50 years of age or older had been recruited. Three groups were recruited: persons with no prior diagnosis of cataracts, persons diagnosed with cataracts but who had not had surgery, and persons who had had cataract surgery on both eyes within the past 5 years. A series of fixed-choice and open-ended questions was then presented to qualified participants. Questions related to vision, quality of life, and the understanding and perceptions of cataract surgery.Results: Two-thirds of respondents reported having frequent eye examinations. More than half indicated that they had discussed cataract surgery with an eye doctor, most often with an ophthalmologist. They reported that the benefits of surgery were most often mentioned (68%), but lens options were infrequently mentioned (39%). Of those who had had surgery, 81% elected to do so on the advice of their health care professional. About 85% of respondents who had had surgery felt well educated about the procedure, though only 75% felt they understood their lens and vision options. Three-quarters of those who had had cataract surgery wished they had had the surgery sooner, and reported that they were enjoying life more after surgery.Conclusion: The ophthalmologist plays an important role in preparing patients for cataract surgery. Discussing both the timing of the surgery and the patient’s lens options are critical for appropriate care; the survey results suggest room for improvement in this regard. Respondents reported they wished they had had surgery sooner, based primarily on their improved quality of life postoperatively. Keywords: cataract surgery, intraocular lens, perception, quality of life
- 1 August 2014
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. 8, 1595-602
Open AccessA survey of potential and previous cataract-surgery patients: what the ophthalmologist should know
A survey of potential and previous cataract-surgery patients: what the ophthalmologist should know Bonnie An Henderson,1 Kerry Solomon,2 Samuel Masket,3 Richard Potvin,4 Edward J Holland,5 Robert Cionni,6 Helga Sandoval2 1Ophthalmic Consultants of Boston, Boston, MA, 2Carolina Eyecare Research Institute, Carolina Eyecare Physicians, Mount Pleasant, SC, 3Advanced Vision Care, Los Angeles, CA, 4Science in Vision, Akron, NY, 5Cincinnati Eye Institute, Cincinnati, OH, 6Eye Institute of Utah, Salt Lake City, UT, USA Objective: This study utilized a phone survey to characterize patient perceptions of cataract surgery and the manner in which the ophthalmologist contributes to the patient’s understanding in electing cataract surgery.Patients and methods: Calls were made from a randomized membership list of the American Association of Retired Persons until 1,000 respondents 50 years of age or older had been recruited. Three groups were recruited: persons with no prior diagnosis of cataracts, persons diagnosed with cataracts but who had not had surgery, and persons who had had cataract surgery on both eyes within the past 5 years. A series of fixed-choice and open-ended questions was then presented to qualified participants. Questions related to vision, quality of life, and the understanding and perceptions of cataract surgery.Results: Two-thirds of respondents reported having frequent eye examinations. More than half indicated that they had discussed cataract surgery with an eye doctor, most often with an ophthalmologist. They reported that the benefits of surgery were most often mentioned (68%), but lens options were infrequently mentioned (39%). Of those who had had surgery, 81% elected to do so on the advice of their health care professional. About 85% of respondents who had had surgery felt well educated about the procedure, though only 75% felt they understood their lens and vision options. Three-quarters of those who had had cataract surgery wished they had had the surgery sooner, and reported that they were enjoying life more after surgery.Conclusion: The ophthalmologist plays an important role in preparing patients for cataract surgery. Discussing both the timing of the surgery and the patient’s lens options are critical for appropriate care; the survey results suggest room for improvement in this regard. Respondents reported they wished they had had surgery sooner, based primarily on their improved quality of life postoperatively. Keywords: cataract surgery, intraocular lens, perception, quality of life