Gerhard Hindricks
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Gerhard Hindricks has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Bollmann
Department of Electrophysiology, Heart Center Leipzig, Leipzig, Germany
7 shared publications - Jedrzej Kosiuk
Department of Rhythmology, Helios Clinic Köthen, Köthen, Germany
6 shared publications - Sebastian Hilbert
Department of Electrophysiology, Heart Center Leipzig, Leipzig, Germany
5 shared publications - Philipp Sommer
Universität Leipzig – Herzzentrum
4 shared publications - Sascha Rolf
Department of Electrophysiology, Heart Center, University of Leipzig, Leipzig, Germany
4 shared publications - Sergio Richter
Department of Electrophysiology Heart Center—University of Leipzig Leipzig Germany
4 shared publications
Latest Publications
- 13 April 2017
- Published by Georg Thieme Verlag KG in Aktuelle Kardiologie
- Vol. 6 (02) , 156-158
Telemedizin und Herzinsuffizienz – Sinn oder Unsinn
Bei einer weltweiten hohen Anzahl an herzinsuffizienten Menschen mit hoher Hospitalisationsrate und Morbidität ist die Telemedizin ein sinnvolles Tool, um frühzeitige Dekompensationen bei subjektiv unverändertem Allgemeinzustand des Patienten zu erkennen und diesem entgegenzuwirken. Durch das ständige Monitoring kann ebenso eine erhöhte Compliance gewonnen werden, speziell in ländlichen Gebieten, die eine geringe Ärztedichte aufweisen. Die Telemedizin bedeutet eine ergänzende Mitbetreuung zur leitliniengerechten Therapie der Herzinsuffizienz. With a worldwide high number of patients suffering from heart failure and the associated high hospitalization rates and morbidity, telemedicine is a useful tool for recognizing and counteracting early decompensations despite a subjectively unchanged general condition of the patient. Continuous monitoring can also lead to increased compliance, especially in rural areas with low physician density. Telemedicine means supplementary co-care for the management of cardiac insufficiency.
- 13 April 2017
- Published by Georg Thieme Verlag KG in Aktuelle Kardiologie
- Vol. 6 (02) , 156-158
Telemedizin und Herzinsuffizienz – Sinn oder Unsinn
Bei einer weltweiten hohen Anzahl an herzinsuffizienten Menschen mit hoher Hospitalisationsrate und Morbidität ist die Telemedizin ein sinnvolles Tool, um frühzeitige Dekompensationen bei subjektiv unverändertem Allgemeinzustand des Patienten zu erkennen und diesem entgegenzuwirken. Durch das ständige Monitoring kann ebenso eine erhöhte Compliance gewonnen werden, speziell in ländlichen Gebieten, die eine geringe Ärztedichte aufweisen. Die Telemedizin bedeutet eine ergänzende Mitbetreuung zur leitliniengerechten Therapie der Herzinsuffizienz. With a worldwide high number of patients suffering from heart failure and the associated high hospitalization rates and morbidity, telemedicine is a useful tool for recognizing and counteracting early decompensations despite a subjectively unchanged general condition of the patient. Continuous monitoring can also lead to increased compliance, especially in rural areas with low physician density. Telemedicine means supplementary co-care for the management of cardiac insufficiency.
- Open Access
- 5 April 2017
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 15 (1) , 1-6
Association of atrial fibrillation susceptibility genes, atrial fibrillation phenotypes and response to catheter ablation: a gene-based analysis of GWAS data
Previous studies have suggested PITX2, KCNN3 and ZFHX3 as atrial fibrillation (AF) susceptibility genes. Single common genetic polymorphisms of those genes have been linked with AF phenotypes and rhythm outcome of AF catheter ablation although their mechanisms remain elusive. New gene-based association tests may help clarifying genotype–phenotype correlations. Therefore, we hypothesized that PITX2, KCNN3 and ZFHX3 associate with left atrial enlargement and persistent AF and subsequently with ablation outcome. Samples from 660 patients with paroxysmal (n = 370) or persistent AF (n = 290) undergoing AF catheter ablation were genotyped for ~1,000,000 SNPs. Gene-based association was investigated using two different gene-based association tests (VEGAS, minSNP). Among the three candidate genes, only ZFHX3 associated with left atrial dilatation and AF recurrence after catheter ablation. This study suggests a contribution of ZFHX3 to AF remodeling and response to therapy. Future and larger studies are necessary to replicate and apply these findings with an emphasis on designing AF pathophysiology-based multi-locus risk scores.
- 5 April 2017
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 15 (1) , 1-6
Open AccessAssociation of atrial fibrillation susceptibility genes, atrial fibrillation phenotypes and response to catheter ablation: a gene-based analysis of GWAS data
Previous studies have suggested PITX2, KCNN3 and ZFHX3 as atrial fibrillation (AF) susceptibility genes. Single common genetic polymorphisms of those genes have been linked with AF phenotypes and rhythm outcome of AF catheter ablation although their mechanisms remain elusive. New gene-based association tests may help clarifying genotype–phenotype correlations. Therefore, we hypothesized that PITX2, KCNN3 and ZFHX3 associate with left atrial enlargement and persistent AF and subsequently with ablation outcome. Samples from 660 patients with paroxysmal (n = 370) or persistent AF (n = 290) undergoing AF catheter ablation were genotyped for ~1,000,000 SNPs. Gene-based association was investigated using two different gene-based association tests (VEGAS, minSNP). Among the three candidate genes, only ZFHX3 associated with left atrial dilatation and AF recurrence after catheter ablation. This study suggests a contribution of ZFHX3 to AF remodeling and response to therapy. Future and larger studies are necessary to replicate and apply these findings with an emphasis on designing AF pathophysiology-based multi-locus risk scores.
- 23 August 2016
- Published by Elsevier in International Journal of Cardiology
- Vol. 223, 915-916
Need for further studies on ivabradine in patients with persistent atrial fibrillation
- 23 August 2016
- Published by Elsevier in International Journal of Cardiology
- Vol. 223, 915-916
Need for further studies on ivabradine in patients with persistent atrial fibrillation
- 23 August 2016
- Published by Elsevier in International Journal of Cardiology
- Vol. 224, 1-3
Renal denervation in challenging anatomy: Current strategies and pre-procedural imaging
- 23 August 2016
- Published by Elsevier in International Journal of Cardiology
- Vol. 224, 1-3
Renal denervation in challenging anatomy: Current strategies and pre-procedural imaging
- 2 November 2015
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 27 (4) , 488-489
Channel-Based Gap Mapping for Pulmonary Vein Isolation
- 2 November 2015
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 27 (4) , 488-489
Channel-Based Gap Mapping for Pulmonary Vein Isolation
- 1 January 2015
- Published by Elsevier in International Journal of Cardiology
- Vol. 179, 27-28
Ivabradine for rate control in atrial fibrillation
- 1 January 2015
- Published by Elsevier in International Journal of Cardiology
- Vol. 179, 27-28
Ivabradine for rate control in atrial fibrillation
- 27 October 2014
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 26 (2) , 233-238
Renal Denervation for Treatment of Cardiac Arrhythmias: State of the Art and Future Directions
Renal Denervation for Treatment of Cardiac Arrhythmias. It has now been more than a quarter of a century since modulation of the sympathetic nervous system was proposed for the treatment of cardiac arrhythmias of different origins. But it has also been some time since some of the early surgical attempts have been abandoned. With the development of ablation techniques, however, new approaches and targets have been recently introduced that have revolutionized our way of thinking about sympathetic modulation. Renal nerve ablation technology is now being successfully used for the treatment of resistant hypertension, but the indication spectrum might broaden and new therapeutic options might arise in the near future.
- 27 October 2014
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 26 (2) , 233-238
Renal Denervation for Treatment of Cardiac Arrhythmias: State of the Art and Future Directions
Renal Denervation for Treatment of Cardiac Arrhythmias. It has now been more than a quarter of a century since modulation of the sympathetic nervous system was proposed for the treatment of cardiac arrhythmias of different origins. But it has also been some time since some of the early surgical attempts have been abandoned. With the development of ablation techniques, however, new approaches and targets have been recently introduced that have revolutionized our way of thinking about sympathetic modulation. Renal nerve ablation technology is now being successfully used for the treatment of resistant hypertension, but the indication spectrum might broaden and new therapeutic options might arise in the near future.
- 17 September 2014
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 26 (2) , 167-175
Sensor‐Based Electromagnetic Navigation to Facilitate Implantation of Left Ventricular Leads in Cardiac Resynchronization Therapy
Introduction Implantation of cardiac resynchronization therapy (CRT) devices can be challenging, time consuming, and fluoroscopy intense. To facilitate placement of left ventricular (LV) leads, a novel electromagnetic navigation system (MediGuide™, St. Jude Medical, St. Paul, MN, USA) has been developed, displaying real‐time 3‐D location of sensor‐embedded delivery tools superimposed on prerecorded X‐ray cine‐loops of coronary sinus venograms. We report our experience and advanced progress in the use of this new electromagnetic tracking system to guide LV lead implantation. Methods and Results Between January 2012 and December 2013, 71 consecutive patients (69 ± 9 years, 76% male) were implanted with a CRT device using the new electromagnetic tracking system. Demographics, procedural data, and periprocedural adverse events were gathered. The impact of the operator's experience, optimized workflow, and improved software technology on procedural data were analyzed. LV lead implantation was successfully achieved in all patients without severe adverse events. Total procedure time measured 87 ± 37 minutes and the median total fluoroscopy time (skin‐to‐skin) was 4.9 (2.5–7.8) minutes with a median dose‐area‐product of 476 (260–1056) cGy*cm2. An additional comparison with conventional CRT device implantations showed a significant reduction in fluoroscopy time from 8.0 (5.8; 11.5) to 4.5 (2.8; 7.3) minutes (P = 0.016) and radiation dose from 603 (330; 969) to 338 (176; 680) cGy*cm2, respectively (P = 0.044 ). Conclusion Use of the new navigation system enables safe and successful LV lead placement with improved orientation and significantly reduced radiation exposure during CRT implantation.
- 17 September 2014
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 26 (2) , 167-175
Sensor‐Based Electromagnetic Navigation to Facilitate Implantation of Left Ventricular Leads in Cardiac Resynchronization Therapy
Introduction Implantation of cardiac resynchronization therapy (CRT) devices can be challenging, time consuming, and fluoroscopy intense. To facilitate placement of left ventricular (LV) leads, a novel electromagnetic navigation system (MediGuide™, St. Jude Medical, St. Paul, MN, USA) has been developed, displaying real‐time 3‐D location of sensor‐embedded delivery tools superimposed on prerecorded X‐ray cine‐loops of coronary sinus venograms. We report our experience and advanced progress in the use of this new electromagnetic tracking system to guide LV lead implantation. Methods and Results Between January 2012 and December 2013, 71 consecutive patients (69 ± 9 years, 76% male) were implanted with a CRT device using the new electromagnetic tracking system. Demographics, procedural data, and periprocedural adverse events were gathered. The impact of the operator's experience, optimized workflow, and improved software technology on procedural data were analyzed. LV lead implantation was successfully achieved in all patients without severe adverse events. Total procedure time measured 87 ± 37 minutes and the median total fluoroscopy time (skin‐to‐skin) was 4.9 (2.5–7.8) minutes with a median dose‐area‐product of 476 (260–1056) cGy*cm2. An additional comparison with conventional CRT device implantations showed a significant reduction in fluoroscopy time from 8.0 (5.8; 11.5) to 4.5 (2.8; 7.3) minutes (P = 0.016) and radiation dose from 603 (330; 969) to 338 (176; 680) cGy*cm2, respectively (P = 0.044 ). Conclusion Use of the new navigation system enables safe and successful LV lead placement with improved orientation and significantly reduced radiation exposure during CRT implantation.